The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up

被引:37
|
作者
Kieser, David C. [1 ]
Ailabouni, Ramez [1 ]
Kieser, Sandra C. J. [2 ]
Wyatt, Michael C. [1 ]
Armour, Paul C. [1 ]
Coates, Mark H. [2 ]
Hooper, Gary J. [1 ]
机构
[1] Univ Otago, Christchurch Sch Med, Dept Orthopaed Surg & Musculoskeletal Med, Christchurch, New Zealand
[2] Univ Otago, Christchurch Sch Med, Dept Radiol, Christchurch, New Zealand
关键词
Acetabular bone loss; custom; osteolysis; pelvic dissociation; 3D print; tri-flanged; TOTAL HIP-ARTHROPLASTY; PELVIC DISCONTINUITY; PRIMARY OSTEOARTHRITIS; REVISION ARTHROPLASTY; NEW-ZEALAND; COMPONENTS; RECONSTRUCTION; CLASSIFICATION; DEFECTS; CUP;
D O I
10.1177/1120700018760817
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. Methods: This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Results: Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, I required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tunnoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n= I I], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. Conclusions: The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.
引用
收藏
页码:668 / 674
页数:7
相关论文
共 50 条
  • [41] Long-Term Clinical Outcomes of 3D-Printed Subperiosteal Titanium Implants: A 6-Year Follow-Up
    Onica, Neculai
    Budala, Dana Gabriela
    Baciu, Elena-Raluca
    Onica, Cezara Andreea
    Geletu, Gabriela Luminita
    Murariu, Alice
    Balan, Mihail
    Pertea, Mihaela
    Stelea, Carmen
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (05):
  • [42] Sport Activity and Clinical Outcomes after Hip Arthroscopy with Acetabular Microfractures at a Minimum 2-Year Follow-Up: A Matched-Pair Controlled Study
    Loppini, Mattia
    La Camera, Francesco
    Gambaro, Francesco Manlio
    Ruggeri, Riccardo
    Grappiolo, Guido
    Della Rocca, Federico
    LIFE-BASEL, 2022, 12 (08):
  • [43] Answer letter concerning "The effect of new preoperative preparation method compared to conventional method in complex acetabular fractures: minimum 2-year follow-up"
    Wang, Pengfei
    Zhuang, Yan
    Zhang, Kun
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (2) : 223 - 223
  • [44] Answer letter concerning “The effect of new preoperative preparation method compared to conventional method in complex acetabular fractures: minimum 2-year follow-up”
    Pengfei Wang
    Yan Zhuang
    Kun Zhang
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 223 - 223
  • [45] Allograft Use in Arthroscopic Labral Reconstruction of the Hip With Front-to-Back Fixation Technique: Minimum 2-Year Follow-up
    White, Brian J.
    Stapleford, Andrea B.
    Hawkes, Tara K.
    Finger, Michael J.
    Herzog, Mackenzie M.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (01): : 26 - 32
  • [46] Posterior Cervical Fusion With Recombinant Human Bone Morphogenetic Protein-2 Complications and Fusion Rate at Minimum 2-Year Follow-Up
    Dorward, Ian G.
    Buchowski, Jacob M.
    Stoker, Geoffrey E.
    Zebala, Lukas P.
    CLINICAL SPINE SURGERY, 2016, 29 (06): : E276 - E281
  • [47] Outcomes of Quadriceps Tendon With Patellar Bone Block Anterior Cruciate Ligament Reconstruction in Adolescent Patients With a Minimum 2-Year Follow-up
    Gagliardi, Alexia G.
    Carry, Patrick M.
    Parikh, Harin B.
    Albright, Jay C.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2020, 48 (01): : 93 - 98
  • [48] Ilizarov frame fixation without bone graft for atrophic humeral shaft nonunion: 28 patients with a minimum 2-year follow-up
    Tomic, Slavko
    Bumbasirevic, Marko
    Lesic, Aleksandar
    Mitkovic, Milorad
    Atkinson, Henry Dushan E.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (08) : 549 - 556
  • [49] Uncemented press-fit total hip arthroplasty using the identifit custom-molding technique - A prospective minimum 2-year follow-up study
    Robinson, RP
    Clark, JE
    JOURNAL OF ARTHROPLASTY, 1996, 11 (03): : 247 - 254
  • [50] Prolonged Postoperative Opioid Use After Arthroscopic Femoroacetabular Impingement Syndrome Surgery: Predictors and Outcomes at Minimum 2-Year Follow-up
    Beck, Edward C.
    Nwachukwu, Benedict U.
    Drager, Justin
    Jan, Kyleen
    Rasio, Jonathan
    Krishnamoorthy, Vignesh P.
    Nho, Shane J.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (11)