The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up

被引:37
|
作者
Kieser, David C. [1 ]
Ailabouni, Ramez [1 ]
Kieser, Sandra C. J. [2 ]
Wyatt, Michael C. [1 ]
Armour, Paul C. [1 ]
Coates, Mark H. [2 ]
Hooper, Gary J. [1 ]
机构
[1] Univ Otago, Christchurch Sch Med, Dept Orthopaed Surg & Musculoskeletal Med, Christchurch, New Zealand
[2] Univ Otago, Christchurch Sch Med, Dept Radiol, Christchurch, New Zealand
关键词
Acetabular bone loss; custom; osteolysis; pelvic dissociation; 3D print; tri-flanged; TOTAL HIP-ARTHROPLASTY; PELVIC DISCONTINUITY; PRIMARY OSTEOARTHRITIS; REVISION ARTHROPLASTY; NEW-ZEALAND; COMPONENTS; RECONSTRUCTION; CLASSIFICATION; DEFECTS; CUP;
D O I
10.1177/1120700018760817
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. Methods: This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Results: Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, I required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tunnoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n= I I], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. Conclusions: The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.
引用
收藏
页码:668 / 674
页数:7
相关论文
共 50 条
  • [21] The use of bilobed porous-coated acetabular components without structural bone graft for type III acetabular defects in revision total hip arthroplasty - A prospective study with a minimum 2-year follow-up
    Moskal, JT
    Shen, FH
    JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 867 - 873
  • [22] Standardized 3D-printed trabecular titanium augment and cup for acetabular bone defects in revision hip arthroplasty: a mid-term follow-up study
    Linjie Hao
    Yumin Zhang
    Weiguo Bian
    Wei Song
    Kun Li
    Nengjun Wang
    Pengfei Wen
    Tao Ma
    Journal of Orthopaedic Surgery and Research, 18
  • [23] Standardized 3D-printed trabecular titanium augment and cup for acetabular bone defects in revision hip arthroplasty: a mid-term follow-up study
    Hao, Linjie
    Zhang, Yumin
    Bian, Weiguo
    Song, Wei
    Li, Kun
    Wang, Nengjun
    Wen, Pengfei
    Ma, Tao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [24] Criminal activities and substance use of patients with major affective disorders and schizophrenia: a 2-year follow-up
    Hodgins, S
    Lapalme, M
    Toupin, J
    JOURNAL OF AFFECTIVE DISORDERS, 1999, 55 (2-3) : 187 - 202
  • [25] Cementless 3D Printed Highly Porous Titanium-Coated Baseplate Total Knee Arthroplasty: Survivorship and Outcomes at 2-Year Minimum Follow-Up
    Sultan, Assem A.
    Mahmood, Bilal
    Samuel, Linsen T.
    Stearns, Kim L.
    Molloy, Robert M.
    Moskal, Joseph T.
    Krebs, Viktor E.
    Harwin, Steven F.
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2020, 33 (03) : 279 - 283
  • [26] Risk factors for septic arthritis and multiple arthroscopic washouts: minimum 2-year follow-up at a major trauma centre
    Victor Lu
    Andrew Zhou
    Hassan Abbas Hussain
    Azeem Thahir
    Matija Krkovic
    Clinical Rheumatology, 2022, 41 : 2513 - 2523
  • [27] Risk factors for septic arthritis and multiple arthroscopic washouts: minimum 2-year follow-up at a major trauma centre
    Lu, Victor
    Zhou, Andrew
    Hussain, Hassan Abbas
    Thahir, Azeem
    Krkovic, Matija
    CLINICAL RHEUMATOLOGY, 2022, 41 (08) : 2513 - 2523
  • [28] Clinical and radiological outcomes of autologous humeral bone grafting for radial head reconstruction: a minimum 2-year follow-up
    Fiorentino, Gennaro
    Arduini, Mario
    D'Ambrosi, Riccardo
    Usuelli, Federico Giuseppe
    Catellani, Francesco
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (06): : 1153 - 1161
  • [29] Clinical and radiological outcomes of autologous humeral bone grafting for radial head reconstruction: a minimum 2-year follow-up
    Gennaro Fiorentino
    Mario Arduini
    Riccardo D’Ambrosi
    Federico Giuseppe Usuelli
    Francesco Catellani
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 1153 - 1161
  • [30] A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients
    Xiao Geng
    Yang Li
    Feng Li
    Xinguang Wang
    Ke Zhang
    Zhongjun Liu
    Hua Tian
    Journal of Orthopaedic Surgery and Research, 15