Covered airway stent placement for malignant tracheobronchial strictures in patients with an endotracheal tube

被引:3
|
作者
Kim, M. J.
Shin, J. H. [1 ]
Park, J. -H.
Kim, J. H.
Song, H. -Y.
Park, J.
Cho, Y. C.
Kim, S. H.
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, 388-1,Poongnap 2 Dong, Seoul 138736, South Korea
基金
新加坡国家研究基金会;
关键词
EXPANDABLE METALLIC STENTS; TERM-FOLLOW-UP; RETROSPECTIVE ANALYSIS; CLINICAL-OUTCOMES; OBSTRUCTION; MANAGEMENT; SILICONE; STENOSIS; SURVIVAL;
D O I
10.1016/j.crad.2016.06.114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the technical feasibility and safety of covered airway stent placement for malignant tracheobronchial strictures in patients with an endotracheal tube. MATERIALS AND METHODS: Data regarding retrievable, expandable, metal stent placement under fluoroscopic guidance in 20 patients with an endotracheal tube inserted for malignant tracheobronchial strictures were retrospectively analysed. The clinical effectiveness was assessed using the following variables: technical and clinical success; procedure and stent-related complications; and duration of intubation following stent placement. RESULTS: Stent placement was technically successful in all 20 patients (100%), and with 19 of the 20 patients (95%) showing symptomatic improvement within 5 days. The endotracheal tube could be removed during (n=7) or after (n=12) stent placement, and the mean duration of intubation following stent placement was 1.4 days (range 0-3 days). One patient could not have his endotracheal tube removed and he died 9 days following stent placement in an intubated state. There were no procedure-related complications. Stent-related complications in three patients included partial (n=2) and complete (n=1) stent migration, all of which were managed with placement of a second stent (n=2) or stent removal and placement of a second stent (n=1). CONCLUSION: Covered airway stent placement under fluoroscopic guidance in patients with an endotracheal tube inserted for malignant tracheobronchial strictures, is both technically feasible and safe. (C) 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1120 / 1125
页数:6
相关论文
共 50 条
  • [41] Laryngeal reflex before and after placement of airway interventions:: Endotracheal tube and Laryngeal Mask Airway™
    Tanaka, A
    Isono, S
    Ishikawa, T
    Nishino, T
    ANESTHESIOLOGY, 2005, 102 (01) : 20 - 25
  • [42] Placement of Self-Expanding Metallic Tracheobronchial Y Stent with Laryngeal Mask Airway
    Pertzov, B.
    Abdelrahman, N.
    Rosengarten, D.
    Kassirer, M.
    Gershman, E.
    Kramer, M. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [43] Outcomes of self-expandable metal stent placement for malignant oesophageal strictures
    Gao, F.
    Xu, Y. L.
    Liu, Y. J.
    Sun, M. H.
    CLINICAL RADIOLOGY, 2020, 75 (02) : 156.e21 - 156.e27
  • [44] RISK FACTORS FOR DEVELOPMENT OF PAIN AFTER STENT PLACEMENT FOR MALIGNANT ESOPHAGEAL STRICTURES
    Ma, Gene K.
    Kochman, Michael L.
    GASTROENTEROLOGY, 2018, 154 (06) : S908 - S908
  • [45] Usefulness of Cross Wired Metallic Stents for Endoscopic Bilateral Stent in Stent Placement and Revision in Patients With Malignant Hilar Biliary Strictures
    Moon, Jong Ho
    Kim, Jong Hyeok
    Choi, Hyun Jong
    Yoo, Kyo-Sang
    Cheon, Young Koog
    Cho, Young Deok
    Lee, Moon Sung
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (05) : AB304 - AB304
  • [46] Retrospective Comparison of Internally and Externally Covered Retrievable Stent Placement for Patients With Benign Urethral Strictures Caused by Traumatic Injury
    Na, Han Kyu
    Song, Ho-Young
    Yeo, Hyun Jin
    Park, Jung-Hoon
    Kim, Jin Hyoung
    Park, Hyungkeun
    Kim, Choung-soo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : W55 - W61
  • [47] Fully covered self-expanding metallic stent placement for benign refractory esophageal strictures
    Kahalekar V.
    Gupta D.T.
    Bhatt P.
    Shukla A.
    Bhatia S.
    Indian Journal of Gastroenterology, 2017, 36 (3) : 197 - 201
  • [48] Indications and clinical outcomes of fully covered self-expandable metallic tracheobronchial stents in patients with malignant airway diseases
    Akram, Muhammad Junaid
    Khalid, Usman
    Abu Bakar, Muhammad
    Ashraf, Mohammad Bilal
    Butt, Faheem Mehmood
    Khan, Faheem
    EXPERT REVIEW OF RESPIRATORY MEDICINE, 2020, 14 (11) : 1173 - 1181
  • [49] Newly Designed Stent for Endoscopic Bilateral Stent-in-Stent Placement of Metallic Stent in Patients with Malignant Hilar Biliary Strictures: Multicenter Prospective Feasibility Study
    Park, Do Hyun
    Lee, Sang Soo
    Moon, Jong Ho
    Choi, Hyun Jong
    Cha, Sang-Woo
    Kim, Jong Hyeok
    Seo, Dong Wan
    Lee, Sung Koo
    Park, Sang-Heum
    Lee, Moon Sung
    Kim, Sun-Joo
    Kim, Myung-Hwan
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) : AB142 - AB142
  • [50] Immediate Placement of a Temporary Covered Stent for the Management of Iatrogenic Malignant Esophageal Perforation
    Hong-Tao Hu
    Ho-Young Song
    Jin Hyoung Kim
    CardioVascular and Interventional Radiology, 2011, 34 : 886 - 888