Covered airway stent placement for malignant tracheobronchial strictures in patients with an endotracheal tube

被引:3
|
作者
Kim, M. J.
Shin, J. H. [1 ]
Park, J. -H.
Kim, J. H.
Song, H. -Y.
Park, J.
Cho, Y. C.
Kim, S. H.
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, 388-1,Poongnap 2 Dong, Seoul 138736, South Korea
基金
新加坡国家研究基金会;
关键词
EXPANDABLE METALLIC STENTS; TERM-FOLLOW-UP; RETROSPECTIVE ANALYSIS; CLINICAL-OUTCOMES; OBSTRUCTION; MANAGEMENT; SILICONE; STENOSIS; SURVIVAL;
D O I
10.1016/j.crad.2016.06.114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the technical feasibility and safety of covered airway stent placement for malignant tracheobronchial strictures in patients with an endotracheal tube. MATERIALS AND METHODS: Data regarding retrievable, expandable, metal stent placement under fluoroscopic guidance in 20 patients with an endotracheal tube inserted for malignant tracheobronchial strictures were retrospectively analysed. The clinical effectiveness was assessed using the following variables: technical and clinical success; procedure and stent-related complications; and duration of intubation following stent placement. RESULTS: Stent placement was technically successful in all 20 patients (100%), and with 19 of the 20 patients (95%) showing symptomatic improvement within 5 days. The endotracheal tube could be removed during (n=7) or after (n=12) stent placement, and the mean duration of intubation following stent placement was 1.4 days (range 0-3 days). One patient could not have his endotracheal tube removed and he died 9 days following stent placement in an intubated state. There were no procedure-related complications. Stent-related complications in three patients included partial (n=2) and complete (n=1) stent migration, all of which were managed with placement of a second stent (n=2) or stent removal and placement of a second stent (n=1). CONCLUSION: Covered airway stent placement under fluoroscopic guidance in patients with an endotracheal tube inserted for malignant tracheobronchial strictures, is both technically feasible and safe. (C) 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1120 / 1125
页数:6
相关论文
共 50 条
  • [21] Corrosive esophageal strictures: Effectiveness of placement of a covered retrievable expandable nitinol stent
    Seo, TS
    Ko, G
    Sung, K
    Yoon, H
    Kim, S
    Song, H
    RADIOLOGY, 2001, 221 : 447 - 447
  • [22] Placement of a Covered Esophageal Stent for Palliation of a Malignant Esophagopulmonary Fistula
    Kumar, Anand Raman
    Olson, Mira
    Anand, Girish
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2009, 104 : S200 - S200
  • [23] STENT PLACEMENT IS JUSTIFIABLE IN END-STAGE PATIENTS WITH MALIGNANT AIRWAY TUMORS
    SUTEDJA, G
    SCHRAMEL, F
    VANKRALINGEN, K
    POSTMUS, PE
    RESPIRATION, 1995, 62 (03) : 148 - 150
  • [24] Outcomes and Survival in Malignant Central Airway Obstruction with Airway Stent Placement
    O'Brien, Shane
    Anandan, Lavanya
    Shea, Rosie
    Dunwoody, Roisin
    Mullin, Monica
    Lansing, Meryl
    Ghattas, Sandy
    Estenor, Danielle
    Gorur, Pavaan
    Bhamani, Amyn
    George, Jeremy
    Janes, Sam
    Navani, Neal
    Thakrar, Ricky
    LUNG CANCER, 2025, 200
  • [26] Temporary stent placement during radiation therapy in patients with malignant esophageal strictures: Initial experience
    Shin, JH
    Ko, G
    Yoon, H
    Sung, K
    Song, H
    RADIOLOGY, 2002, 225 : 162 - 163
  • [27] Outcome of the placement of self expandable metallic stent for malignant colorectal strictures
    Shimaya, Koji
    Takahashi, Kazunori
    Yamamoto, Yoichi
    Itoh, Satoko
    Hananata, Norihiro
    Kanazawa, Kousuke
    Numao, Hiroshi
    Munakata, Masaki
    Fukuda, Shinsaku
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2014, 29 : 299 - 299
  • [28] Expandable metallic stent placement for palliation of malignant strictures of the pancreatic duct
    Linder, JD
    Tarnasky, PR
    GASTROINTESTINAL ENDOSCOPY, 2005, 61 (05) : AB194 - AB194
  • [29] Evaluation of a newly modified nonflared fully covered metal stent, 12 mm in diameter, for intraductal placement in patients with malignant biliary strictures: a feasibility study
    Choi, Hyun Jong
    Moon, Jong Ho
    Lee, Yun Nah
    Kim, Hyun Su
    Choi, Moon Han
    Lee, Tae Hoon
    Cha, Sang-Woo
    Cho, Young Deok
    Park, Sang-Heum
    Kim, Sun-Joo
    ENDOSCOPY, 2016, 48 (07) : 625 - 631
  • [30] The beck airway air flow monitor as an aid for evaluation of endotracheal tube placement in neonatal patients
    Cook, RT
    Moglia, BA