An in vitro model for fluid pressurization of screw holes in metal-backed total joint components

被引:7
|
作者
Kurtz, SM
Harrigan, TP
Herr, M
Manley, MT
机构
[1] Exponent Inc, Philadelphia, PA 19104 USA
[2] Drexel Univ, Philadelphia, PA 19104 USA
来源
JOURNAL OF ARTHROPLASTY | 2005年 / 20卷 / 07期
关键词
osteolysis; fluid pressure; implant design; conformity; thickness; surface finish;
D O I
10.1016/j.arth.2004.11.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fluid pressure may stimulate osteolysis near screw holes in joint arthroplasty components. We developed a generalized in vitro model of a polyethylene liner and metal backing with a screw hole to investigate whether implant design factors influence local fluid pressure. We observed an order of magnitude of variation in the peak screw hole pressure (from 16.0 and 163 kPa) under clinically relevant loading conditions. Of the implant factors investigated, the surface finish of the metallic base plate had the greatest effect on peak screw hole fluid pressures; the thickness of the polyethylene liner, as well as the gap between the liner and the base plate, were also significant design variables. Our data suggest that unpolished metal base plates, thick polyethylene liners, and tight conformity between the liner and the metal base plate will all contribute to significantly reduced peak screw hole fluid pressures in joint arthroplasty.
引用
收藏
页码:932 / 938
页数:7
相关论文
共 50 条
  • [1] CEMENTED METAL-BACKED TIBIAL COMPONENTS
    DENNIS, DA
    ORTHOPEDICS, 1994, 17 (09) : 838 - 840
  • [2] FRACTURE DISSOCIATION OF THE POLYETHYLENE IN METAL-BACKED PATELLAR COMPONENTS IN TOTAL KNEE ARTHROPLASTY
    LOMBARDI, AV
    ENGH, GA
    VOLZ, RG
    ALBRIGO, JL
    BRAINARD, BJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05): : 675 - 679
  • [3] Outcomes of Trabecular Metal-backed glenoid components in anatomic total shoulder arthroplasty
    Watson, Scott T.
    Gudger, Garland K., Jr.
    Long, Catherine D.
    Tokish, John M.
    Tolan, Stefan J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (03) : 493 - 498
  • [4] FAILURE MECHANISMS OF METAL-BACKED PATELLAR COMPONENTS
    STULBERG, SD
    STULBERG, BN
    HAMATI, Y
    TSAO, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (236) : 88 - 105
  • [5] POLYETHYLENE WEAR OF METAL-BACKED TIBIAL COMPONENTS IN TOTAL AND UNICOMPARTMENTAL KNEE PROSTHESES
    ENGH, GA
    DWYER, KA
    HANES, CK
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01): : 9 - 17
  • [6] Metal-backed and all-polyethylene tibial components in total knee replacement
    Rodriguez, JA
    Baez, N
    Rasquinha, V
    Ranawat, CS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 174 - 183
  • [7] All-Polyethylene versus Metal-Backed Tibial Components in Total Knee Arthroplasty
    AbuMoussa, Samuel
    White, Charles Cody
    Eichinger, Josef K.
    Friedman, Richard J.
    JOURNAL OF KNEE SURGERY, 2019, 32 (08) : 714 - 718
  • [8] A comparison of all-polyethylene and metal-backed tibial components in total knee arthroplasty
    Dojcinovic, S.
    Selmi, T. Ait Si
    Servien, E.
    Verdonk, P. C. M.
    Neyret, P.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (04): : 364 - 372
  • [9] CONCERNS AND IMPROVEMENTS WITH CEMENTLESS METAL-BACKED ACETABULAR COMPONENTS
    CALLAGHAN, JJ
    KIM, YS
    BROWN, TD
    PEDERSEN, DR
    JOHNSTON, RC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (311) : 76 - 84
  • [10] Deformation of metal-backed acetabular components and the impact of liner thickness in a cadaveric model
    David Markel
    Judd Day
    Ryan Siskey
    Imants Liepins
    Steven Kurtz
    Kevin Ong
    International Orthopaedics, 2011, 35 : 1131 - 1137