Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates

被引:12
|
作者
Steffen, B. [1 ]
Gerth, Ch. [1 ]
Caselle, M. [2 ]
Felber, M. [1 ]
Kozak, T. [1 ]
Makowski, D. R. [3 ]
Mavric, U. [1 ]
Mielczarek, A. [3 ]
Peier, P. [1 ,4 ]
Przygoda, K. [1 ]
Rota, L. [2 ,5 ]
机构
[1] Deutsch Elektronen Synchrotron DESY, MSK, D-22607 Hamburg, Germany
[2] Karlsruhe Inst Technol KIT, IPE, D-76344 Eggenstein Leopoldshafen, Germany
[3] Lodz Univ Technol TUL, DMCS, PL-90924 Lodz, Poland
[4] Eidgenoss Inst Metrol, Bern, Switzerland
[5] SLAC Natl Accelerator Lab, Menlo Pk, CA USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2020年 / 91卷 / 04期
关键词
LINEAR-ARRAY DETECTOR; LASER;
D O I
10.1063/1.5142833
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile, electro-optical detection can be exploited for non-invasive bunch length measurements at accelerators. We have developed a very compact and robust electro-optical detection system based on spectral decoding for single-shot longitudinal bunch profile monitoring at the European X-ray Free Electron Laser (XFEL) for electron bunch lengths down to 200 fs (rms). Apart from the GaP crystal and the corresponding laser optics at the electron beamline, all components are housed in 19 in. chassis for rack mount and remote operation inside the accelerator tunnel. An advanced laser synchronization scheme based on radio-frequency down-conversion has been developed for locking a custom-made Yb-fiber laser to the radio-frequency of the European XFEL accelerator. In order to cope with the high bunch repetition rate of the superconducting accelerator, a novel linear array detector has been employed for spectral measurements of the Yb-fiber laser pulses at frame rates of up to 2.26 MHz. In this paper, we describe all sub-systems of the electro-optical detection system as well as the measurement procedure in detail and discuss the first measurement results of longitudinal bunch profiles of around 400 fs (rms) with an arrival-time jitter of 35 fs (rms).
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates
    Steffen, B.
    Czwalinna, M. K.
    2023 48TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, IRMMW-THZ, 2023,
  • [2] A single-shot, high-repetition rate scheme for electro-optic detection of short pulses
    Roussel, E.
    Evain, C.
    Le Parquier, M.
    Szwaj, C.
    Bielawski, S.
    Manceron, L.
    Brubach, J. -B.
    Tordeux, M. -A.
    Ricaud, J. -P.
    Cassinari, L.
    Labat, M.
    Couprie, M. -E.
    Roy, P.
    ADVANCES IN X-RAY FREE-ELECTRON LASERS INSTRUMENTATION III, 2015, 9512
  • [3] Single-Shot Electro-Optic Measurement of Mid-Infrared Pulses
    Kozina, Michael E.
    Hoffmann, Matthias C.
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [4] Single-Shot, Femtosecond Resolution, Terahertz Pulse Measurement without a Femtosecond Probe via Electro-Optic Transposition
    Walsh, David A.
    Snedden, Edward W.
    Jamison, Steven P.
    2016 41ST INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2016,
  • [5] Single-shot measurement of terahertz electromagnetic pulses by use of electro-optic sampling
    Shan, J
    Weling, AS
    Knoesel, E
    Bartels, L
    Bonn, M
    Nahata, A
    Reider, GA
    Heinz, TF
    OPTICS LETTERS, 2000, 25 (06) : 426 - 428
  • [6] A new single shot THz detection strategy with electro-optic sampling
    Krauspe, Philipp
    Banerji, Natalie
    Rehault, Julien
    TERAHERTZ PHOTONICS II, 2022, 12134
  • [7] Electro-optic technique with improved time resolution for real-time, nondestructive, single-shot measurements of femtosecond electron bunch profiles
    Berden, G
    Jamison, SP
    MacLeod, AM
    Gillespie, WA
    Redlich, B
    van der Meer, AFG
    PHYSICAL REVIEW LETTERS, 2004, 93 (11) : 114802 - 1
  • [8] Single-shot Spectrometers and Realtime THz digitizers, using Diversity Electro-Optic Sampling (DEOS)
    Roussel, E.
    Szwaj, C.
    Evain, C.
    Steffen, B.
    Gerth, C.
    Czwalinna, M. K.
    Jalali, B.
    Bielawski, S.
    2023 48TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, IRMMW-THZ, 2023,
  • [9] Electro-optic time lens model for femtosecond pulses
    Marinho, Francisco J.
    Bernardo, Luis M.
    PHOTON MANAGEMENT III, 2008, 6994
  • [10] Single-shot Measurement of THz pulses with sub-picosecond resolution and Megahertz acquisition rates
    Roussel, Eleonore
    Szwaj, Christophe
    Evain, Clement
    Le Parquier, Marc
    Bielawski, Serge
    Jiang, Tianwei
    Jalali, Bahram
    2019 44TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2019,