Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates

被引:12
|
作者
Steffen, B. [1 ]
Gerth, Ch. [1 ]
Caselle, M. [2 ]
Felber, M. [1 ]
Kozak, T. [1 ]
Makowski, D. R. [3 ]
Mavric, U. [1 ]
Mielczarek, A. [3 ]
Peier, P. [1 ,4 ]
Przygoda, K. [1 ]
Rota, L. [2 ,5 ]
机构
[1] Deutsch Elektronen Synchrotron DESY, MSK, D-22607 Hamburg, Germany
[2] Karlsruhe Inst Technol KIT, IPE, D-76344 Eggenstein Leopoldshafen, Germany
[3] Lodz Univ Technol TUL, DMCS, PL-90924 Lodz, Poland
[4] Eidgenoss Inst Metrol, Bern, Switzerland
[5] SLAC Natl Accelerator Lab, Menlo Pk, CA USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2020年 / 91卷 / 04期
关键词
LINEAR-ARRAY DETECTOR; LASER;
D O I
10.1063/1.5142833
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile, electro-optical detection can be exploited for non-invasive bunch length measurements at accelerators. We have developed a very compact and robust electro-optical detection system based on spectral decoding for single-shot longitudinal bunch profile monitoring at the European X-ray Free Electron Laser (XFEL) for electron bunch lengths down to 200 fs (rms). Apart from the GaP crystal and the corresponding laser optics at the electron beamline, all components are housed in 19 in. chassis for rack mount and remote operation inside the accelerator tunnel. An advanced laser synchronization scheme based on radio-frequency down-conversion has been developed for locking a custom-made Yb-fiber laser to the radio-frequency of the European XFEL accelerator. In order to cope with the high bunch repetition rate of the superconducting accelerator, a novel linear array detector has been employed for spectral measurements of the Yb-fiber laser pulses at frame rates of up to 2.26 MHz. In this paper, we describe all sub-systems of the electro-optical detection system as well as the measurement procedure in detail and discuss the first measurement results of longitudinal bunch profiles of around 400 fs (rms) with an arrival-time jitter of 35 fs (rms).
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Single-shot measurement of ultrafast time-varying phase modulation induced by femtosecond laser pulses with arbitrary polarization
    Hartinger, Klaus
    Bartels, Randy A.
    APPLIED PHYSICS LETTERS, 2008, 92 (02)
  • [42] First single-shot and non-intercepting longitudinal bunch diagnostics for comb-like beam by means of Electro-Optic Sampling
    Pompili, R.
    Cianchi, A.
    Alesini, D.
    Anania, M. P.
    Bacci, A.
    Bellaveglia, M.
    Castellano, M.
    Chiadroni, E.
    DiGiovenale, D.
    Di Pirro, G.
    Gatti, G.
    Giorgianni, F.
    Ferrario, M.
    Lupi, S.
    Massimo, F.
    Mostacci, A.
    Rossi, A. R.
    Vaccarezza, C.
    Villa, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 740 : 216 - 221
  • [43] Raman amplified wavelength-time spectroscopy with picometer spectral resolution and single-shot detection
    Chou, Jason
    Solli, Daniel R.
    Jalali, Bahram
    2007 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2007, : 222 - 223
  • [44] Time-resolved and time-integrated single-shot laser-induced plasma experiments using nanosecond and femtosecond laser pulses
    Sirven, JB
    Bousquet, B
    Canioni, L
    Sarger, L
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (07) : 1033 - 1039
  • [45] High-Resolution Time-Correlated Single-Photon Counting Using Electro-Optic Sampling
    Crockett, Benjamin
    van Howe, James
    Montaut, Nicola
    Morandotti, Roberto
    Azana, Jose
    LASER & PHOTONICS REVIEWS, 2022, 16 (10)
  • [46] Real-Time Detection for Camera Sensing System : Adaptive Cascade Single-Shot Detector
    Ding, Bojian
    Gu, Lize
    Zhu, Xiaoning
    PROCEEDINGS OF THE 2019 14TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2019), 2019, : 2154 - 2160
  • [47] Synchronizing single-shot high-energy iodine photodissociation laser PALS and high-repetition-rate femtosecond Ti:sapphire laser system
    Dostal, J.
    Dudzak, R.
    Pisarczyk, T.
    Pfeifer, M.
    Huynh, J.
    Chodukowski, T.
    Kalinowska, Z.
    Krousky, E.
    Skala, J.
    Hrebicek, J.
    Medrik, T.
    Golasowski, J.
    Juha, L.
    Ullschmied, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (04):
  • [48] Compact Single-Shot Terahertz Time-Domain Spectroscopy System for Magneto-Optics with a Mini-Coil Pulsed Magnet
    Andalcio, Ayana M.
    Breen, Patrick
    Hendricks, Lisa Anne
    Sarkar, Tapash J.
    Noe, G. Timothy, II
    Woods, Gary L.
    Kono, Junichiro
    Leotin, Jean
    2013 38TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2013,
  • [49] Spatial resolution improvement of single-shot digital optical frequency comb-based Brillouin optical time domain analysis utilizing multiple pump pulses
    Liang, Zihao
    Pan, Jingshun
    Gao, Shecheng
    Sui, Qi
    Feng, Yuanhua
    Li, Fan
    Li, Jianping
    Liu, Weiping
    Li, Zhaohui
    OPTICS LETTERS, 2018, 43 (15) : 3534 - 3537
  • [50] Single-shot real-time detection technique for pulse-front tilt and curvature of femtosecond pulsed beams with multiple-slit spatiotemporal interferometry
    Li, Zhaoyang
    Miyanaga, Noriaki
    Kawanaka, Junji
    OPTICS LETTERS, 2018, 43 (13) : 3156 - 3159