Amount of Frequency Compression in Bimodal Cochlear Implant Users Is a Poor Predictor for Audibility and Spatial Hearing

被引:2
|
作者
Sharma, Snandan [1 ]
Nogueira, Waldo [2 ]
van Opstal, A. John [1 ]
Chalupper, Josef [3 ]
Mens, Lucas H. M. [4 ]
van Wanrooij, Marc M. [1 ]
机构
[1] Radboud Univ Nijmegen, Donders Inst Brain Cognit & Behav, Dept Biophys, Nijmegen, Netherlands
[2] Hannover Med Sch, Dept Otolaryngol Cluster Excellence Hearin, Hannover, Germany
[3] European Res Ctr, Adv Bion, Hannover, Germany
[4] Radboud Univ Nijmegen, Med Ctr, Donders Inst Brain Cognit & Behav, Dept Otorhinolaryngol, Nijmegen, Netherlands
来源
关键词
SOUND LOCALIZATION; LOUDNESS GROWTH; PERCEPTION; RECIPIENTS; LISTENERS; CUES; AID;
D O I
10.1044/2021_JSLHR-20-00653
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Purpose: Speech understanding in noise and horizontal sound localization is poor in most cochlear implant (CI) users with a hearing aid (bimodal stimulation). This study investigated the effect of static and less-extreme adaptive frequency compression in hearing aids on spatial hearing. By means of frequency compression, we aimed to restore high-frequency audibility, and thus improve sound localization and spatial speech recognition. Method: Sound-detection thresholds, sound localization, and spatial speech recognition were measured in eight bimodal CI users, with and without frequency compression. We tested two compression algorithms: a static algorithm, which compressed frequencies beyond the compression knee point (160 or 480 Hz), and an adaptive algorithm, which aimed to compress only consonants leaving vowels unaffected (adaptive knee-point frequencies from 736 to 2946 Hz). Results: Compression yielded a strong audibility benefit (high-frequency thresholds improved by 40 and 24 dB for static and adaptive compression, respectively), no meaningful improvement in localization performance (errors remained > 30 deg), and spatial speech recognition across all participants. Localization biases without compression (toward the hearing-aid and implant side for low- and high-frequency sounds, respectively) disappeared or reversed with compression. The audibility benefits provided to each bimodal user partially explained any individual improvements in localization performance; shifts in bias; and, for six out of eight participants, benefits in spatial speech recognition. Conclusions: We speculate that limiting factors such as a persistent hearing asymmetry and mismatch in spectral overlap prevent compression in bimodal users from improving sound localization. Therefore, the benefit in spatial release from masking by compression is likely due to a shift of attention to the ear with the better signal-to-noise ratio facilitated by compression, rather than an improved spatial selectivity. Supplemental Material: https://doi.org/10.23641/asha.16869485
引用
收藏
页码:5000 / 5013
页数:14
相关论文
共 50 条
  • [31] Phantom Stimulation for Cochlear Implant Users With Residual Low-Frequency Hearing
    Krueger, Benjamin
    Buechner, Andreas
    Nogueira, Waldo
    EAR AND HEARING, 2022, 43 (02): : 631 - 645
  • [32] Frequency selectivity of contralateral residual acoustic hearing in bimodal cochlear implant users, and limitations on the ability to match the pitch of electric and acoustic stimuli
    Green, Tim
    Faulkner, Andrew
    Rosen, Stuart
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2012, 51 (05) : 389 - 398
  • [33] The Contribution of a Frequency-Compression Hearing Aid to Contralateral Cochlear Implant Performance
    Perreau, Ann E.
    Bentler, Ruth A.
    Tyler, Richard S.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2013, 24 (02) : 105 - 120
  • [34] Impact of Reverberation on Speech Perception in Noise in Bimodal/Bilateral Cochlear Implant Users with and without Residual Hearing
    Koenig, Clara
    Baumann, Uwe
    Stoever, Timo
    Weissgerber, Tobias
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)
  • [35] Preimplant Hearing Aid Fittings and Aided Audibility for Pediatric Cochlear Implant Recipients
    Nickerson, Alissa
    Davidson, Lisa S.
    Uchanski, Rosalie M.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2019, 30 (08) : 703 - 711
  • [36] Spatial Release From Masking in Simulated Cochlear Implant Users With and Without Access to Low-Frequency Acoustic Hearing
    Williges, Ben
    Dietz, Mathias
    Hohmann, Volker
    Juergens, Tim
    TRENDS IN HEARING, 2015, 19
  • [37] Spatial Hearing by Bilateral Cochlear Implant Users With Temporal Fine-Structure Processing
    Ausili, Sebastian A.
    Agterberg, Martijn J. H.
    Engel, Andreas
    Voelter, Christiane
    Thomas, Jan Peter
    Brill, Stefan
    Snik, Ad F. M.
    Dazert, Stefan
    Van Opstal, A. John
    Mylanus, Emmanuel A. M.
    FRONTIERS IN NEUROLOGY, 2020, 11
  • [38] Restoration of spatial hearing in adult cochlear implant users with single-sided deafness
    Litovsky, Ruth Y.
    Moua, Keng
    Godar, Shelly
    Kan, Alan
    Misurelli, Sara M.
    Lee, Daniel J.
    HEARING RESEARCH, 2019, 372 : 69 - 79
  • [39] Effects of temporal fine structure preservation on spatial hearing in bilateral cochlear implant users
    Fischer, T.
    Schmid, C.
    Kompis, M.
    Mantokoudis, G.
    Caversaccio, M.
    Wimmer, W.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 150 (02): : 673 - 686
  • [40] Binaural advantages in users of bimodal and bilateral cochlear implant devices
    Kokkinakis, Kostas
    Pak, Natalie
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 135 (01): : EL47 - EL53