Measuring lower limb circumference and volume - introduction of a novel optical 3D volumetric measurement system

被引:12
|
作者
Tischer, Thomas [1 ]
Oye, Sebastian [1 ]
Wolf, Andreas [1 ]
Feldhege, Frank [1 ]
Jacksteit, Robert [1 ]
Mittelmeier, Wolfram [1 ]
Bader, Rainer [1 ]
Mau-Moeller, Anett [1 ]
机构
[1] Univ Med Rostock, Dept Orthopaed, Doberaner Str 142, D-18057 Rostock, Germany
来源
关键词
cardiovascular disease; edema; swelling; venous disease; volume measurement; RELIABILITY; LYMPHEDEMA; EDEMA;
D O I
10.1515/bmt-2018-0100
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study comprised two experiments: (1) the reliability of a novel optical three-dimensional (3D) volumetric measurement system (BODYTRONIC (R) 600) for the assessment of lower limb circumference and volume; (2) the comparison of data obtained from BODYTRONIC (R) 600 with that provided by computed tomography (CT) for accuracy estimation. Reliability was assessed in 20 healthy subjects. Accuracy was determined by comparing the deviations in the surface topology of two 3D models obtained from BODYTRONIC (R) 600 and CT. Reliability was very high for leg circumference measures [coefficient of variations (CVs) range 0.3%-1.3%] and slightly lower for foot circumference (CVs around 2.0%). Reliability of leg volume was also found to be very high (CVs <= 2.5%). Differences in surface topology between BODYTRONIC (R) 600 and CT were primarily below 1 mm indicating high accuracy. The volumes of the foot were higher (range 0.9% 1.7%) and that of the leg, lower (range 1.0% 1.3%) compared to CT. The BODYTRONIC (R) 600 system provides fast, highly reliable and accurate measures of lower limb circumference and volume and can be considered as a valuable measurement tool for use in various research and clinical applications.
引用
收藏
页码:237 / 241
页数:5
相关论文
共 50 条
  • [41] Automatic 3D measuring system for optical scanning of axial fan blades
    Lin, Alan C.
    Chang Hui-Chin
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2011, 57 (5-8): : 701 - 717
  • [42] A robust feature points matching algorithm in 3D optical measuring system
    Yuan, Jianying
    Liu, Xianyong
    Qiu, ZhiQiang
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 5193 - +
  • [43] 3D venous anatomy of the venous network of the lower limb
    Chahim, Maxime
    Uhl, Jean-Francois
    Mogorron, Jose Ramon
    Delmas, Vincent
    ANNALS OF MEDICINE, 2019, 51 : S59 - S59
  • [44] System-Level Assessment of Volumetric 3D Vehicular MIMO Antenna Based on Measurement
    Posselt, Adrian
    Friedrich, Aline
    Ekiz, Levent
    Klemp, Oliver
    Geck, Bernd
    2014 INTERNATIONAL CONFERENCE ON CONNECTED VEHICLES AND EXPO (ICCVE), 2014, : 222 - 226
  • [45] An Improved Design of 3D Swept-Volume Volumetric Display
    Sun, Chuanwei
    Chang, Xiaowei
    Cai, Mingming
    Liu, Jingao
    JOURNAL OF COMPUTERS, 2014, 9 (01) : 235 - 242
  • [46] 3D Volumetric Measurement Of Absolute Brain Volume Changes In patients with Acute Spontaneous Intracerebral Hemorrhage.
    Ahmad, Hamad
    Hassanzadeh, Bahareh
    Mughni, Azam
    El-Gengaihy, Ahmed
    Kirmani, Jawad
    STROKE, 2009, 40 (04) : E212 - E212
  • [47] A novel dual-camera calibration method for 3D optical measurement
    Gai, Shaoyan
    Da, Feipeng
    Dai, Xianqiang
    OPTICS AND LASERS IN ENGINEERING, 2018, 104 : 126 - 134
  • [48] Glenohumeral Joint Volume Measurement in Patients with Shoulder Instability: A 3D Volumetric Magnetic Resonance Arthrographic Study
    Gueclue, Derya
    Unlu, Elif Nisa
    Arican, Mehmet
    Acar, Oguzhan
    Uludag, Veysel
    Ogul, Hayri
    MEDICINA-LITHUANIA, 2024, 60 (09):
  • [49] Peculiarities of optical formation and filtering the images and diffraction patterns of volumetric objects applied to 3D measuring technologies
    Chugui, Y
    NONLINEAR OPTICAL PHENOMENA AND COHERENT OPTICS IN INFORMATION TECHNOLOGIES - ICONO'98, 1999, 3733 : 339 - 348