Measuring lower limb circumference and volume - introduction of a novel optical 3D volumetric measurement system

被引:12
|
作者
Tischer, Thomas [1 ]
Oye, Sebastian [1 ]
Wolf, Andreas [1 ]
Feldhege, Frank [1 ]
Jacksteit, Robert [1 ]
Mittelmeier, Wolfram [1 ]
Bader, Rainer [1 ]
Mau-Moeller, Anett [1 ]
机构
[1] Univ Med Rostock, Dept Orthopaed, Doberaner Str 142, D-18057 Rostock, Germany
来源
关键词
cardiovascular disease; edema; swelling; venous disease; volume measurement; RELIABILITY; LYMPHEDEMA; EDEMA;
D O I
10.1515/bmt-2018-0100
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study comprised two experiments: (1) the reliability of a novel optical three-dimensional (3D) volumetric measurement system (BODYTRONIC (R) 600) for the assessment of lower limb circumference and volume; (2) the comparison of data obtained from BODYTRONIC (R) 600 with that provided by computed tomography (CT) for accuracy estimation. Reliability was assessed in 20 healthy subjects. Accuracy was determined by comparing the deviations in the surface topology of two 3D models obtained from BODYTRONIC (R) 600 and CT. Reliability was very high for leg circumference measures [coefficient of variations (CVs) range 0.3%-1.3%] and slightly lower for foot circumference (CVs around 2.0%). Reliability of leg volume was also found to be very high (CVs <= 2.5%). Differences in surface topology between BODYTRONIC (R) 600 and CT were primarily below 1 mm indicating high accuracy. The volumes of the foot were higher (range 0.9% 1.7%) and that of the leg, lower (range 1.0% 1.3%) compared to CT. The BODYTRONIC (R) 600 system provides fast, highly reliable and accurate measures of lower limb circumference and volume and can be considered as a valuable measurement tool for use in various research and clinical applications.
引用
收藏
页码:237 / 241
页数:5
相关论文
共 50 条
  • [31] 3D Optical measuring technologies and systems
    Chugui, YV
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 1, 2004, : 29 - 44
  • [32] 3D Optical measuring technologies and systems
    Chugui, YV
    Eighth International Symposium on Laser Metrology: MACRO-, MICRO-, AND NANO-TECHNOLOGIES APPLIED IN SCIENCE, ENGINEERING, AND INDUSTRY, 2005, 5776 : 576 - 588
  • [33] Small objects volume measuring using 3D
    Honec, P.
    Annals of DAAAM for 2004 & Proceedings of the 15th International DAAAM Symposium: INTELLIGNET MANUFACTURING & AUTOMATION: GLOBALISATION - TECHNOLOGY - MEN - NATURE, 2004, : 159 - 160
  • [34] Digital Volumetric Measurements Based on 3D Scans of the Lower Limb: A Valid and Reproducible Method for Evaluation in Lymphedema Therapy
    Schiltz, Daniel
    Diesch, Sophia Theresa
    Kiermeier, Natalie
    Eibl, Dominik
    Felmerer, Gunther
    Schreml, Stephan
    Biermann, Niklas
    Prantl, Lukas
    Taeger, Christian D.
    ANNALS OF VASCULAR SURGERY, 2024, 105 : 209 - 217
  • [35] Non-contact optical flexible 3D measurement system
    Luo, Ming
    Duan, Fajie
    Wang, Xuejun
    Wang, Chunhe
    Ye, Shenghua
    Guangdian Gongcheng/Opto-Electronic Engineering, 1996, 23 (03): : 18 - 23
  • [36] Full-hemisphere automatical optical 3D measurement system
    Kuhnstedt, P
    Notni, G
    Schreiber, W
    Gerber, J
    SENSORS, SENSOR SYSTEMS, AND SENSOR DATA PROCESSING, 1997, 3100 : 261 - 265
  • [37] An External Parameter Optimize Method for 3D Optical Measurement System
    Ma, Heyao
    He, Wantao
    Meng, Xianglin
    Li, Dan
    INTERNATIONAL JOURNAL OF SECURITY AND ITS APPLICATIONS, 2016, 10 (05): : 87 - 94
  • [38] Optical 3D measurement system for micro-profile and surface roughness measurement
    Frankowski, Gottfried
    F & M; Feinwerktechnik, Mikrotechnik, Messtechnik, 1998, 106 (09): : 612 - 615
  • [39] A Texture Energy Measurement Technique for 3D Volumetric Data
    Suzuki, Motofumi T.
    Yaginuma, Yoshitomo
    Kodama, Haruo
    2009 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC 2009), VOLS 1-9, 2009, : 3779 - 3785
  • [40] Automatic 3D measuring system for optical scanning of axial fan blades
    Alan C. Lin
    Chang Hui-Chin
    The International Journal of Advanced Manufacturing Technology, 2011, 57 : 701 - 717