Sensitive determination of epinephrine in pharmaceutical preparation by flow injection coupled with chemiluminescence detection and mechanism study

被引:21
|
作者
Liu, Yanming [1 ]
Liu, Zhuanli [1 ]
Shi, Yanmei [1 ]
机构
[1] Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; flow-injection; epinephrine; mechanism study; CAPILLARY-ELECTROPHORESIS; GOLD NANOPARTICLE; ELECTROCHEMILUMINESCENCE DETECTION; SPECTROPHOTOMETRIC DETERMINATION; HUMAN URINE; HUMAN SERUM; SYSTEM; CATECHOLAMINES; FORMULATIONS; NOREPINEPHRINE;
D O I
10.1002/bio.1186
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel, rapid and sensitive method was described for the determination of epinephrine (EP) using flow injection analysis coupled with chemiluminescence (CL) detection, which based on EP enhanced the weak CL emission of luminol-KIO(4) system in NaOH solution. Parameters affecting the CL intensity and reproducibility were optimized systematically. Under the optimized experiment conditions, the net CL intensity was proportional to the concentration of EP in the range of 5.0 x 10(-8) to 1.5 x 10(-6) mol/L with a detection limit of 1.9 x 10(-9) mol/L. The relative standard deviation (RSD) was found to be 0.7% for 13 replicate determinations of 3.0 x 10(-7) mol/L EP. The applicability of the proposed method was illustrated in the determination of EP in pharmaceutical preparation. The recoveries of EP at different levels in EP hydrochloride injection were between 95.4 and 104.7%. One assay procedure takes only 27 s, and the sampling rate was calculated about to be 130 samples/h. The possible mechanism of the enhanced CL intensity was studied by examining CL spectra and UV-vis spectra. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [21] Development of a sensitive flow injection-chemiluminescence detection method for the indirect determination of propranolol
    Tsogas, GZ
    Stergiou, DV
    Vlessidis, AG
    Evmiridis, NP
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 151 - 157
  • [22] A Sensitive Procedure for the Rapid Determination of Mandelic Acid by Flow Injection Analysis and Chemiluminescence Detection
    Alam, Seikh Mafiz
    Jeon, Chi Wan
    Karim, Mohammad Mainul
    Lee, Sang Hak
    Wabaidur, Saikh Mohammad
    Suh, Yeoun Suk
    Chung, Hye Young
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2009, 30 (01): : 102 - 106
  • [23] Sensitive determination of 2-methoxyestradiol in pharmaceutical preparations and serum samples using flow injection chemiluminescence
    Yao, Hanchun
    Zhang, Min
    Zeng, Wenyuan
    Zeng, Xiaoying
    Zhang, Zhenzhong
    LUMINESCENCE, 2014, 29 (03) : 261 - 265
  • [24] Flow injection chemiluminescence determination of epinephrine using epinephrine-imprinted polymer as recognition material
    Du, JX
    Shen, LH
    Lu, JR
    ANALYTICA CHIMICA ACTA, 2003, 489 (02) : 183 - 189
  • [25] Selective determination of amino acids using flow injection analysis coupled with chemiluminescence detection
    Costin, JW
    Francis, PS
    Lewis, SW
    ANALYTICA CHIMICA ACTA, 2003, 480 (01) : 67 - 77
  • [26] Determination of epinephrine by flow-injection analysis using luminol-hexacyanoferrate(III) chemiluminescence detection
    Kojlo, A
    Nalewajko, E
    CHEMIA ANALITYCZNA, 2004, 49 (05): : 653 - 663
  • [27] Determination of puerarin in pharmaceutical injection by flow injection analysis with acidic potassium permanganate-glyoxal chemiluminescence detection
    Wei, Gaili
    Wei, Chunlong
    Dang, Gaochao
    Yao, Hanchun
    Li, Hua
    ANALYTICAL LETTERS, 2007, 40 (11) : 2179 - 2191
  • [28] Flow injection chemiluminescence analysis for highly sensitive determination of noscapine
    Zhuang, YF
    Cai, XL
    Yu, JS
    Ju, HX
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2004, 162 (2-3) : 457 - 462
  • [29] Determination of dipyridamole by flow injection analysis with chemiluminescence detection
    Yang, ML
    Li, LQ
    Feng, ML
    Lü, JR
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (02) : 161 - 163
  • [30] Flow-injection with chemiluminescence detection for the determination of iproniazid
    Alonso, MCS
    Zamora, LL
    Calatayud, JM
    ANALYTICA CHIMICA ACTA, 2001, 437 (02) : 225 - 231