Precut technique using an injection needle: A retrospective study on a new ancillary procedure for pleural biopsy

被引:0
|
作者
Mizumori, Yasuyuki [1 ]
Hirano, Katsuya [1 ]
Hirata, Nobuya [1 ]
Hiraoka, Ryota [1 ]
Takahashi, Sayaka [1 ]
Kominami, Ryota [1 ]
Miyake, Kohei [1 ]
Takenouchi, Masaki [1 ]
Kato, Tomohiro [1 ]
Kume, Sachie [1 ]
Higashino, Sachiko [1 ]
Nakahara, Yasuharu [1 ]
Kawamura, Tetsuji [1 ]
机构
[1] Natl Hosp Org, Dept Resp Med, Himeji Med Ctr, 68 Honmachi, Himeji, Hyogo 6708520, Japan
关键词
cryobiopsy; injection needle; pleural biopsy; precut technique; thoracoscopy; FEASIBILITY; SAFETY; KNIFE; CRYOBIOPSY; DIAGNOSIS;
D O I
10.1097/MD.0000000000029377
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The effectiveness of thoracoscopic biopsy as a diagnostic method for pleural diseases has been reported; however, obtaining a sufficient specimen size is sometimes difficult. Therefore, an ancillary technique, the precut technique using an injection needle, was devised to address this problem. This study aimed to evaluate the effectiveness and safety of the novel precut technique in patients with undiagnosed pleural effusion. This retrospective study included 22 patients who underwent pleural biopsy using the precut technique to examine exudative pleural effusion of unknown etiology. Thoracoscopy was performed under local anesthesia. The biopsy procedure was performed as follows: a needle was inserted into the pleura around the lesion using a semiflexible thoracoscope; the needle was positioned to make an incision in the pleura while injecting 1% lidocaine with epinephrine and lifting the pleura from the fascia; 2 or 3 precut incision lines were arranged in a triangle; and the specimen was obtained from the parietal pleura using forceps or a cryoprobe. Patient data including age, number of biopsies, biopsy specimen size, pathological and final diagnosis, and postoperative complications were examined. All patients were male with an average age of 74 years. Pleural effusion was found on the right and left sides in 16 and 6 patients, respectively. The average major axis of the biopsy specimens was 18 mm (range, 10-30 mm), which was sufficient to establish a pathological diagnosis. Only 1 patient experienced minor temporal bleeding as a complication. The precut technique enabled the procurement of specimens sufficient in size for pleural biopsy.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] PERCUTANEOUS MUSCLE BIOPSY NEEDLE FOR THE HORSE - A NEW DESIGN AND TECHNIQUE
    MAY, K
    SOUTHWESTERN VETERINARIAN, 1981, 34 (02): : 101 - 104
  • [32] Technique of synovial biopsy of metacarpophalangeal joints using the needle arthroscope
    Levente Gáspár
    Zoltán Szekanecz
    Balázs Dezső
    Gyula Szegedi
    Zoltán Csernátony
    Kálmán Szepesi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2003, 11 : 50 - 52
  • [33] Technique of synovial biopsy of metacarpophalangeal joints using the needle arthroscope
    Gáspár, L
    Szekanecz, Z
    Dezsö, B
    Szegedi, G
    Csernátony, Z
    Szepesi, K
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (01) : 50 - 52
  • [34] Plugged percutaneous liver biopsy using Tru-cut needle and coils: A retrospective study
    Krantikumar Rathod
    Hemant Deshmukh
    Sridhar Sundaram
    Hariharaprakash Radhakrishnan
    Dhaval Thakkar
    Nitinkumar Ramani
    Shobna Bhatia
    Indian Journal of Gastroenterology, 2022, 41 : 424 - 429
  • [35] Plugged percutaneous liver biopsy using Tru-cut needle and coils: A retrospective study
    Rathod, Krantikumar
    Deshmukh, Hemant
    Sundaram, Sridhar
    Radhakrishnan, Hariharaprakash
    Thakkar, Dhaval
    Ramani, Nitinkumar
    Bhatia, Shobna
    INDIAN JOURNAL OF GASTROENTEROLOGY, 2022, 41 (05) : 424 - 429
  • [36] PERCUTANEOUS NEEDLE ASPIRATION BIOPSY OF CHEST LESIONS - NEW INSTRUMENT AND NEW TECHNIQUE
    WANG, KP
    KELLY, SJ
    BRITT, JE
    CHEST, 1988, 93 (05) : 993 - 997
  • [37] Suprapapillary Needle Knife Fistulotomy Versus Conventional Precut Sphincterotomy in Difficult Biliary Cannulation: A Retrospective Comparative Study
    Baspinar, Batuhan
    Odemi, Bulent
    Erdogan, Cagdas
    Yuksel, Mahmut
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2022, 32 (06): : 700 - 706
  • [38] HIGH ACCURACY OF TRANSDUODENAL ENDOSCOPIC FINE NEEDLE BIOPSY USING A 19 G FLEXIBLE NEEDLE: A HUGE RETROSPECTIVE MULTICENTER STUDY
    De Nucci, G.
    Petrone, M. C.
    Imperatore, N.
    Forti, E.
    Grassia, R.
    Sabatino, G.
    Mirante, V. G.
    Giovanelli, S.
    Vecchi, M.
    Manno, M.
    Fabbri, C.
    Arcidiacono, P. G.
    Manes, G.
    DIGESTIVE AND LIVER DISEASE, 2019, 51 : E120 - E120
  • [39] Fine-needle aspiration biopsy - New application for an old technique
    Belitsky, P
    Gupta, R
    TRANSPLANTATION, 2001, 71 (06) : 709 - 710
  • [40] A NEW TECHNIQUE FOR TRANS-CUTANEOUS FINE NEEDLE-BIOPSY
    ROTHENBERGER, K
    PENSEL, J
    FORTSCHRITTE DER MEDIZIN, 1980, 98 (34) : 1283 - 1286