Precut technique using an injection needle: A retrospective study on a new ancillary procedure for pleural biopsy

被引:0
|
作者
Mizumori, Yasuyuki [1 ]
Hirano, Katsuya [1 ]
Hirata, Nobuya [1 ]
Hiraoka, Ryota [1 ]
Takahashi, Sayaka [1 ]
Kominami, Ryota [1 ]
Miyake, Kohei [1 ]
Takenouchi, Masaki [1 ]
Kato, Tomohiro [1 ]
Kume, Sachie [1 ]
Higashino, Sachiko [1 ]
Nakahara, Yasuharu [1 ]
Kawamura, Tetsuji [1 ]
机构
[1] Natl Hosp Org, Dept Resp Med, Himeji Med Ctr, 68 Honmachi, Himeji, Hyogo 6708520, Japan
关键词
cryobiopsy; injection needle; pleural biopsy; precut technique; thoracoscopy; FEASIBILITY; SAFETY; KNIFE; CRYOBIOPSY; DIAGNOSIS;
D O I
10.1097/MD.0000000000029377
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The effectiveness of thoracoscopic biopsy as a diagnostic method for pleural diseases has been reported; however, obtaining a sufficient specimen size is sometimes difficult. Therefore, an ancillary technique, the precut technique using an injection needle, was devised to address this problem. This study aimed to evaluate the effectiveness and safety of the novel precut technique in patients with undiagnosed pleural effusion. This retrospective study included 22 patients who underwent pleural biopsy using the precut technique to examine exudative pleural effusion of unknown etiology. Thoracoscopy was performed under local anesthesia. The biopsy procedure was performed as follows: a needle was inserted into the pleura around the lesion using a semiflexible thoracoscope; the needle was positioned to make an incision in the pleura while injecting 1% lidocaine with epinephrine and lifting the pleura from the fascia; 2 or 3 precut incision lines were arranged in a triangle; and the specimen was obtained from the parietal pleura using forceps or a cryoprobe. Patient data including age, number of biopsies, biopsy specimen size, pathological and final diagnosis, and postoperative complications were examined. All patients were male with an average age of 74 years. Pleural effusion was found on the right and left sides in 16 and 6 patients, respectively. The average major axis of the biopsy specimens was 18 mm (range, 10-30 mm), which was sufficient to establish a pathological diagnosis. Only 1 patient experienced minor temporal bleeding as a complication. The precut technique enabled the procurement of specimens sufficient in size for pleural biopsy.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Percutaneous coaxial needle biopsy using the spacer technique: a novel and easy modification to increase procedure safety
    Coucher, JR
    Connor, P
    CLINICAL RADIOLOGY, 2005, 60 (08) : 926 - 929
  • [22] Value of ultrasonically guided needle biopsy of pleural masses: An under-utilized technique
    Hsu, WH
    Chiang, CD
    Hsu, JY
    Chen, CY
    Chiang, CS
    Lee, T
    JOURNAL OF CLINICAL ULTRASOUND, 1997, 25 (03) : 119 - 125
  • [23] STUDY OF 50 CASES OF PLEURAL BY NEEDLE-BIOPSY OF PLEURA EFFUSION
    JINDEL, D
    KALA, S
    PANGARIA, A
    CLINICIAN, 1980, 44 (09): : 390 - 394
  • [24] Pathological Profile of Exudative Pleural Effusion using Pleural Biopsy by Abram's Needle: A Hospital-based Observational Study
    Reddy, K. Surendar
    Sowmya, J.
    Rao, V. Chetan
    Waghray, Pradyut
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (03) : 56 - 59
  • [25] Diagnostic Yield of Closed Pleural Biopsy Using Cope's Needle in the Diagnosis of Exudative Pleural Effusion
    Goswami, Preetam
    Das, Anirban
    Biswas, Rathindra Nath
    Sen, Pronoy
    Barik, Rana
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (10) : DC01 - DC04
  • [26] Exudative pleural effusions: Comparative study of image assisted Abram needle pleural biopsy and medical thoracoscopy
    Mohamed, Ahmed Sh.
    Abo-Sheisha, Dina M.
    Shamloula, Maha Mostafa
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2014, 63 (03): : 625 - 628
  • [27] FINE-NEEDLE ASPIRATION BIOPSY OF THYROID-NODULES - ASSESSMENT OF THE HISTOLOGICAL STUDY OF THE SAMPLE, USING A NEW TECHNIQUE
    DOMINGUEZ, M
    FRANCO, C
    CONTRERAS, L
    TORRES, J
    VOLPATO, R
    CERPA, F
    PEREZ, G
    MARTINEZ, V
    REVISTA MEDICA DE CHILE, 1995, 123 (08) : 982 - 990
  • [28] Comparison between pancreatic duct guide wire-assisted needle knife precut and conventional needle knife precut for periampullary diverticula with difficult cannulation: a retrospective comparative cohort study
    Liu, Wenhui
    Xu, Qinlan
    Shao, Dong
    GLAND SURGERY, 2022, 11 (11) : 1795 - 1800
  • [29] FINE-NEEDLE MAMMARY BIOPSY - ASSESSMENT OF A NEW TECHNIQUE
    MATURANA, M
    CONTRERAS, L
    REVISTA MEDICA DE CHILE, 1993, 121 (12) : 1395 - 1403
  • [30] A new immunohistochemical technique to diagnose prostate cancer on needle biopsy
    Yang, XMJ
    Brendler, C
    Fanger, G
    Dresser, K
    Jiang, Z
    JOURNAL OF UROLOGY, 2002, 167 (04): : 329 - 329