A comparison of the hemoglobin-based oxygen carrier HBOC-201 to other low-volume resuscitation fluids in a model of controlled hemorrhagic shock

被引:35
|
作者
Sampson, JB
Davis, MR
Mueller, DL
Kashyap, VS
Jenkins, DH
Kerby, JD
机构
[1] Wilford Hall USAF Med Ctr, Dept Gen Surg, Lackland AFB, TX 78236 USA
[2] Univ Texas, Hlth Sci Ctr, Dept Surg, San Antonio, TX USA
关键词
hemoglobin-based oxygen carrier (HBOC); oxygen therapeutic; resuscitation; hypotension;
D O I
10.1097/01.TA.0000084519.47163.77
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The ideal resuscitation fluid for military applications would be effective at low volumes, thereby reducing logistical constraints. We have previously shown that the bovine hemoglobin-based oxygen carrier HBOC-201 is an effective low-volume resuscitation fluid. The goal of this experiment was to evaluate the effectiveness of RBOC-201 in comparison with other low-volume resuscitation fluids in a swine model of controlled hemorrhagic shock. Methods: Forty-two immature female Yorkshire swine (55-70 kg) were divided into seven groups of six. Animals were hemorrhaged to a mean arterial pressure of 30 nun Hg. After 45 minutes, animals were resuscitated to a mean arterial pressure of 60 mm Hg with one of the following agents: hypertonic saline 7.5% (HTS), hypertonic saline 7.5%/Dextran-70 6% (HSD), pentastarch 6%, hetastarch 6%, or HBOC-201. Lactated Ringer's (LR) solution was used as a standard resuscitation control. Another group of animals received no resuscitation. Resuscitation was continued for 4 hours. Hemodynamic variables and oxygen consumption were measured continuously. Arterial and mixed venous blood gases and serum lactate levels were measured at intervals throughout the experiment. Data were analyzed using analysis of variance with Tukey's post hoc test when appropriate. Significance was defined as p < 0.05. Results. Five of six animals in the no-resuscitation control group, six of six in the HTS group, and one animal in the HSD group died before completion of the study. All other animals survived to completion. Animals receiving resuscitation with HBOC-201 had significantly lower cardiac output, mixed venous oxygen saturation levels, and urinary output throughout the resuscitation period; however, there were no differences with regard to lactate, base excess, or oxygen consumption. Animals receiving HBOC-201 required significantly less fluid than any other group. Conclusion: In this model, hypotensive resuscitation with HBOC-201 restores tissue oxygenation and reverses anaerobic metabolism at significantly lower volumes when compared with HTS, HSD, pentastarch, or hetastarch solutions. These data suggest that HBOC-201 would be an effective primary resuscitation fluid for far-forward military or rural trauma settings where logistic constraints and prolonged transport times are common. However, when HBOC-201 is administered as a primary resuscitation fluid in hypotensive protocols, common clinical markers for determining adequacy of resuscitation may not be useful.
引用
收藏
页码:747 / 754
页数:8
相关论文
共 50 条
  • [31] The polymerized bovine hemoglobin-based oxygen-carrying solution (HBOC-201) is not toxic to neural cells in culture
    Ortegon, DP
    Davis, MR
    Dixon, PS
    Smith, DL
    Josephs, JD
    Mueller, DL
    Jenkins, DH
    Kerby, JD
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 53 (06): : 1068 - 1072
  • [32] RESUSCITATION WITH A HEMOGLOBIN BASED OXYGEN CARRIER (HBOC) WITH AND WITHOUT L-ARGININE (LA) IN A SWINE MODEL OF HEMORRHAGIC SHOCK (HS)
    Wang, X.
    Yordanova, V.
    Grosse, S.
    Stern, S.
    SHOCK, 2009, 31 : 45 - 45
  • [33] Concomitant infusion of nitroprusside attenuates vasoconstriction associated with the hemoglobin based oxygen carrier HBOC-201 in pre-hospital resuscitation in swine
    Scultetus, Anke
    Arnaud, Francoise
    Haque, Ashraful
    Auker, Charles
    McCarron, Richard
    Freilich, Daniel
    INFLAMMATION RESEARCH, 2010, 59 : S27 - S27
  • [34] Measuring relative circulating blood volume: Use of a hemoglobin-based oxygen carrier (HBOC) in a rabbit model
    Jahr, JS
    Lurie, F
    Xi, S
    Kuznetsova, OA
    Driessen, B
    ANESTHESIOLOGY, 2000, 93 (3A) : U134 - U134
  • [35] Bovine hemoglobin-based oxygen-carrying solution (HBOC-201) improves flap survival in a rat model of epigastric flap failure
    Ortegon, DP
    Davis, MR
    Sampson, JB
    Dick, EJ
    Kashyap, V
    Kerby, JD
    MICROSURGERY, 2006, 26 (03) : 203 - 206
  • [36] Extracorporeal membrane oxygenation in piglets using a polymerized bovine hemoglobin-based oxygen-carrying solution (HBOC-201)
    York, GB
    DiGeronimo, RJ
    Wilson, BJ
    Cofer, BR
    Breuer, CK
    Josephs, JD
    Smith, DL
    Sorrells, DL
    JOURNAL OF PEDIATRIC SURGERY, 2002, 37 (10) : 1387 - 1392
  • [37] Hemoglobin-based oxygen carriers: Clinical application of HBOC-201 as an alternative to red blood cells for machine perfusion in liver transplantation
    Moein, Mahmoudreza
    Ahmed, Maham
    Arafa, Fatema
    Saidi, Reza F.
    SURGERY IN PRACTICE AND SCIENCE, 2022, 10
  • [38] LIMITED RESUSCITATION WITH A HEMOGLOBIN BASED OXYGEN CARRIER (HBOC) WITH AND WITHOUT NITROGLYCERINE (NTG) IN A MODEL OF UNCONTROLLED HEMORRHAGIC SHOCK (HS) AND BRAIN INJURY (TBI)
    Wang, X.
    Bradbury, N.
    Iwata, A.
    Stern, S.
    SHOCK, 2010, 33 : 48 - 48
  • [39] Innate immune response after resuscitation with hemoglobin-based oxygen carrier and recombinant factor VIIA in uncontrolled hemorrhagic shock in a swine model
    Malkevich, Nina V.
    Dong, Feng
    VanderMolen, Christine A.
    Philbin, Nora B.
    Rice, Jennifer P.
    Scultetus, Anke
    Hong, Jiang
    Arnaud, Francoise
    Hall, Carrie H.
    McGwin, Gerald, Jr.
    Pearce, L. Bruce
    Handrigan, M.
    Ahlers, Stephen
    McCarron, Richard M.
    Freilich, Daniel
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (06): : 1498 - 1510
  • [40] Comparison of the Cardioprotective Effect of Deoxygenated Hemoglobin-based Oxygen Carrier (HBOC) Pretreatment and Ischemia Preconditioning
    You, Zhen
    Li, Tao
    Yang, Chengmin
    Wu, Hong
    Zeng, Yong
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2011, 39 (01): : 7 - 11