A comparison of the hemoglobin-based oxygen carrier HBOC-201 to other low-volume resuscitation fluids in a model of controlled hemorrhagic shock

被引:35
|
作者
Sampson, JB
Davis, MR
Mueller, DL
Kashyap, VS
Jenkins, DH
Kerby, JD
机构
[1] Wilford Hall USAF Med Ctr, Dept Gen Surg, Lackland AFB, TX 78236 USA
[2] Univ Texas, Hlth Sci Ctr, Dept Surg, San Antonio, TX USA
关键词
hemoglobin-based oxygen carrier (HBOC); oxygen therapeutic; resuscitation; hypotension;
D O I
10.1097/01.TA.0000084519.47163.77
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The ideal resuscitation fluid for military applications would be effective at low volumes, thereby reducing logistical constraints. We have previously shown that the bovine hemoglobin-based oxygen carrier HBOC-201 is an effective low-volume resuscitation fluid. The goal of this experiment was to evaluate the effectiveness of RBOC-201 in comparison with other low-volume resuscitation fluids in a swine model of controlled hemorrhagic shock. Methods: Forty-two immature female Yorkshire swine (55-70 kg) were divided into seven groups of six. Animals were hemorrhaged to a mean arterial pressure of 30 nun Hg. After 45 minutes, animals were resuscitated to a mean arterial pressure of 60 mm Hg with one of the following agents: hypertonic saline 7.5% (HTS), hypertonic saline 7.5%/Dextran-70 6% (HSD), pentastarch 6%, hetastarch 6%, or HBOC-201. Lactated Ringer's (LR) solution was used as a standard resuscitation control. Another group of animals received no resuscitation. Resuscitation was continued for 4 hours. Hemodynamic variables and oxygen consumption were measured continuously. Arterial and mixed venous blood gases and serum lactate levels were measured at intervals throughout the experiment. Data were analyzed using analysis of variance with Tukey's post hoc test when appropriate. Significance was defined as p < 0.05. Results. Five of six animals in the no-resuscitation control group, six of six in the HTS group, and one animal in the HSD group died before completion of the study. All other animals survived to completion. Animals receiving resuscitation with HBOC-201 had significantly lower cardiac output, mixed venous oxygen saturation levels, and urinary output throughout the resuscitation period; however, there were no differences with regard to lactate, base excess, or oxygen consumption. Animals receiving HBOC-201 required significantly less fluid than any other group. Conclusion: In this model, hypotensive resuscitation with HBOC-201 restores tissue oxygenation and reverses anaerobic metabolism at significantly lower volumes when compared with HTS, HSD, pentastarch, or hetastarch solutions. These data suggest that HBOC-201 would be an effective primary resuscitation fluid for far-forward military or rural trauma settings where logistic constraints and prolonged transport times are common. However, when HBOC-201 is administered as a primary resuscitation fluid in hypotensive protocols, common clinical markers for determining adequacy of resuscitation may not be useful.
引用
收藏
页码:747 / 754
页数:8
相关论文
共 50 条
  • [21] A Safety and Efficacy Evaluation of Hemoglobin-Based Oxygen Carrier HBOC-201 in a Randomized, Multicenter Red Blood Cell Controlled Trial in Noncardiac Surgery Patients
    Van Hemelrijck, Jan
    Levien, Lewis J.
    Veeckman, Luc
    Pitman, Arkadiy
    Zafirelis, Zafiris
    Standl, Thomas
    ANESTHESIA AND ANALGESIA, 2014, 119 (04): : 766 - 776
  • [22] Effects of a hemoglobin-based oxygen carrier (HBOC-201) and derivatives with altered oxygen affinity and viscosity on systemic and microcirculatory variables in a top-load rat model
    Song, Bjorn Kyungsuck
    Nugent, William H.
    Moon-Massat, Paula F.
    Pittman, Roland N.
    MICROVASCULAR RESEARCH, 2014, 95 : 124 - 130
  • [23] Effects of a hemoglobin-based oxygen carrier (HBOC-201) on hemodynamics and oxygen transport in patients undergoing preoperative hemodilution for elective abdominal aortic surgery
    Kasper, SM
    Walter, M
    Grune, F
    Bischoff, A
    Erasmi, H
    Buzello, W
    ANESTHESIA AND ANALGESIA, 1996, 83 (05): : 921 - 927
  • [24] The use of hemoglobin-based oxygen carrying solution (HBOC-201) for extracorporeal membrane oxygenation (ECMO) in a pig model with ARDS
    Henderson, CL
    Anderson, CM
    Sorrells, DL
    Dick, EJ
    DiGeronimo, RJ
    PEDIATRIC RESEARCH, 2003, 53 (04) : 45A - 45A
  • [25] HBOC-201 resuscitation in a severe swine hemorrhagic shock model simulating combat casualties with delayed evacuation
    Rice, J
    Philbin, N
    Arnaud, F
    Dong, F
    Pearce, B
    McCarron, R
    Freilich, D
    SHOCK, 2005, 23 : 20 - 20
  • [26] Hypotensive resuscitation using a polymerized bovine hemoglobin-based oxygen-carrying solution (HBOC-201) leads to reversal of anaerobic metabolism
    McNeil, JD
    Smith, DL
    Jenkins, DH
    York, GB
    Josephs, JD
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (06): : 1063 - 1075
  • [27] Coagulation and resuscitation patterns following transfusion with polymerized hemoglobin based oxygen carrier (HBOC-201) after severe hemorrhage in swine
    Arnaud, F
    Hammett, M
    Philbin, N
    Rice, J
    Dong, F
    Flournoy, S
    Pearce, B
    McCarron, R
    Freilich, D
    BLOOD, 2004, 104 (11) : 738A - 738A
  • [28] Hemoglobin-based Oxygen Carrier (HBOC-201) and Escalating Doses of Recombinant Factor VIIa (rFVIIa) as a Novel Pre-hospital Resuscitation Fluid in a Swine Model of Severe Uncontrolled Hemorrhaged
    Scultetus, Anke
    Arnaud, Francoise
    Kaplan, Lewis
    Shander, Aryeh
    Philbin, Nora
    Rice, Jennifer
    McCarron, Richard
    Freilich, Daniel
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2011, 39 (02): : 59 - 68
  • [29] Immune effects of decreasing low-molecular weight hemoglobin components of hemoglobin-based oxygen carriers (HBOC) in a swine model of severe controlled hemorrhagic shock
    VanderMolen, C.
    Malkevich, N.
    Philbin, N.
    Rice, J.
    Collier, S.
    Hall, C.
    Ahlers, S.
    McCarron, R.
    Freilich, D.
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2007, 35 (05): : 507 - 517
  • [30] Tissue oxygen monitoring during hemorrhagic shock and resuscitation: A comparison of lactated Ringer's solution, hypertonic saline dextran, and HBOC-201
    Knudson, MM
    Lee, S
    Erickson, V
    Morabito, D
    Derugin, N
    Manley, GT
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 54 (02): : 242 - 252