A comparison of the hemoglobin-based oxygen carrier HBOC-201 to other low-volume resuscitation fluids in a model of controlled hemorrhagic shock

被引:35
|
作者
Sampson, JB
Davis, MR
Mueller, DL
Kashyap, VS
Jenkins, DH
Kerby, JD
机构
[1] Wilford Hall USAF Med Ctr, Dept Gen Surg, Lackland AFB, TX 78236 USA
[2] Univ Texas, Hlth Sci Ctr, Dept Surg, San Antonio, TX USA
关键词
hemoglobin-based oxygen carrier (HBOC); oxygen therapeutic; resuscitation; hypotension;
D O I
10.1097/01.TA.0000084519.47163.77
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The ideal resuscitation fluid for military applications would be effective at low volumes, thereby reducing logistical constraints. We have previously shown that the bovine hemoglobin-based oxygen carrier HBOC-201 is an effective low-volume resuscitation fluid. The goal of this experiment was to evaluate the effectiveness of RBOC-201 in comparison with other low-volume resuscitation fluids in a swine model of controlled hemorrhagic shock. Methods: Forty-two immature female Yorkshire swine (55-70 kg) were divided into seven groups of six. Animals were hemorrhaged to a mean arterial pressure of 30 nun Hg. After 45 minutes, animals were resuscitated to a mean arterial pressure of 60 mm Hg with one of the following agents: hypertonic saline 7.5% (HTS), hypertonic saline 7.5%/Dextran-70 6% (HSD), pentastarch 6%, hetastarch 6%, or HBOC-201. Lactated Ringer's (LR) solution was used as a standard resuscitation control. Another group of animals received no resuscitation. Resuscitation was continued for 4 hours. Hemodynamic variables and oxygen consumption were measured continuously. Arterial and mixed venous blood gases and serum lactate levels were measured at intervals throughout the experiment. Data were analyzed using analysis of variance with Tukey's post hoc test when appropriate. Significance was defined as p < 0.05. Results. Five of six animals in the no-resuscitation control group, six of six in the HTS group, and one animal in the HSD group died before completion of the study. All other animals survived to completion. Animals receiving resuscitation with HBOC-201 had significantly lower cardiac output, mixed venous oxygen saturation levels, and urinary output throughout the resuscitation period; however, there were no differences with regard to lactate, base excess, or oxygen consumption. Animals receiving HBOC-201 required significantly less fluid than any other group. Conclusion: In this model, hypotensive resuscitation with HBOC-201 restores tissue oxygenation and reverses anaerobic metabolism at significantly lower volumes when compared with HTS, HSD, pentastarch, or hetastarch solutions. These data suggest that HBOC-201 would be an effective primary resuscitation fluid for far-forward military or rural trauma settings where logistic constraints and prolonged transport times are common. However, when HBOC-201 is administered as a primary resuscitation fluid in hypotensive protocols, common clinical markers for determining adequacy of resuscitation may not be useful.
引用
收藏
页码:747 / 754
页数:8
相关论文
共 50 条
  • [1] Resuscitation from hemorrhagic shock comparing standard hemoglobin-based oxygen carrier (HBOC)-201 versus 7.5% hypertonic HBOC-201
    Rivera-Chavez, Fernando A.
    Huerta, Sergio
    Brown, Ronnie
    York, Gregory B.
    Minei, Joseph P.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (05): : 1113 - 1119
  • [2] Immune effects of resuscitation with HBOC-201, a hemoglobin-based oxygen carrier, in swine with moderately severe hemorrhagic shock from controlled hemorrhage
    Dong, F
    Hall, CH
    Golech, SA
    Philbin, NB
    Rice, JP
    Gurney, J
    Arnaud, FG
    Hammett, M
    Ma, X
    Flournoy, WS
    Hong, J
    Kaplan, LJ
    Pearce, LB
    McGwin, G
    Ahlers, S
    McCarron, R
    Freilich, D
    SHOCK, 2006, 25 (01): : 50 - 55
  • [3] Bovine hemoglobin-based oxygen carrier (HBOC-201) for resuscitation of uncontrolled, exsanguinating liver injury in swine
    Manning, JE
    Katz, LM
    Brownstein, MR
    Pearce, LB
    Gawryl, MS
    Baker, CC
    SHOCK, 2000, 13 (02): : 152 - 159
  • [4] Low-volume resuscitation with a polymerized bovine hemoglobin-based oxygen-carrying solution (HBOC-201) provides adequate tissue oxygenation for survival in a porcine model of controlled hemorrhage
    York, GB
    Eggers, JS
    Smith, DL
    Jenkins, DH
    McNeil, JD
    Mueller, D
    Josephs, JD
    Kerby, JD
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 55 (05): : 873 - 885
  • [5] RESUSCITATION WITH THE HEMOGLOBIN-BASED OXYGEN CARRIER, HBOC-201, IN A SWINE MODEL OF SEVERE UNCONTROLLED HEMORRHAGE AND TRAUMATIC BRAIN INJURY
    Stern, Susan
    Rice, Jennifer
    Philbin, Nora
    McGwin, Gerald
    Arnaud, Francoise
    Johnson, Todd
    Flournoy, W. Shannon
    Ahlers, Stephen
    Pearce, L. Bruce
    McCarron, Richard
    Freilich, Daniel
    SHOCK, 2009, 31 (01): : 64 - 79
  • [6] A hemoglobin-based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus hetastarch (HEX) in a moderate severity hemorrhagic shock swine model with delayed evacuation
    Philbin, N
    Rice, J
    Gurney, J
    McGwin, G
    Arnaud, F
    Dong, F
    Johnson, T
    Flournoy, WS
    Ahlers, S
    Pearce, LB
    McCarron, R
    Freilich, D
    RESUSCITATION, 2005, 66 (03) : 367 - 378
  • [7] Prolonged low-volume resuscitation with HBOC-201 in a large-animal survival model of controlled hemorrhage
    Fitzpatrick, MCM
    Biggs, KL
    Atkins, MBZ
    Quance-Fitch, FJ
    Dixon, PS
    Savage, MSA
    Jenkins, DH
    Kerby, JD
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (02): : 273 - 281
  • [8] Freeze-dried plasma mitigates the dilution effects of a hemoglobin-based oxygen carrier (HBOC-201) in a model of resuscitation for hemorrhage and hemodilution
    Meledeo, Michael Adam
    Peltier, Grantham C.
    McIntosh, Colby S.
    Taylor, Ashley S.
    Bynum, James A.
    Pusateri, Anthony E.
    Cap, Andrew P.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2019, 87 : S83 - S90
  • [9] The pharmacology of tissue oxygenation by Biopure's hemoglobin-based oxygen carrier, Hemopure® (HBOC-201)
    Pearce, LB
    Gawryl, MS
    OXYGEN TRANSPORT TO TISSUE XXIV, 2003, 530 : 261 - 270
  • [10] Prolonged low-volume resuscitation with HBOC-201 in a large-animal survival model of controlled hemorrhage - Discussion
    Kaufmann, CR
    Moore, FA
    Beilman, G
    Sue, LP
    Fitzpatrick, CM
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (02): : 281 - 283