The Evaluation of Data Completeness and Image Quality in Multiplexing Multi-Pinhole SPECT

被引:15
|
作者
Van Audenhaege, Karen [1 ]
Vanhove, Christian [1 ]
Vandenberghe, Stefaan [1 ]
Van Holen, Roel [1 ]
机构
[1] Univ Ghent, iMinds Med IT, MEDISIP IBiTech, Dept Elect & Informat Syst, B-9000 Ghent, Belgium
关键词
Collimator; image quality; image sampling; instrumentation; molecular imaging; multiplexing; overlap; pinhole; single photon emission computed tomography (SPECT); system design; SLIT-SLAT COLLIMATOR; SAMPLING COMPLETENESS; RECONSTRUCTION; PROJECTIONS; BIODISTRIBUTION; TOMOGRAPHY; SIMULATION; ARTIFACTS; ALGORITHM; LOFTHOLE;
D O I
10.1109/TMI.2014.2361051
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Multi-pinhole collimators are often used in pre-clinical SPECT systems because they have a better resolution-sensitivity tradeoff than parallel hole collimators when imaging small objects. Most multi-pinhole collimators are designed to allow no or only a limited amount of overlap between the different pinhole projections because the ambiguity introduced by multiplexing pinholes can result in artifacts. The origin of these artifacts is still not fully understood, but previous research has already shown that data incompleteness could be part of the explanation. Therefore, we developed a method to investigate data completeness in multiplexing multi-pinhole systems and showed that a certain activity distribution can be successfully reconstructed when the nonmultiplexed data is complete or when the overlap can be sufficiently de-multiplexed. We validated this method using computer simulated phantom data of different multiplexing systems. We also studied contrast-to-noise and nonprewhitening matched filter signal-to-noise ratio (NPW-SNR) to compare the image quality in a single pinhole system with multiplexing systems. We found that our method can indeed be used to evaluate data completeness in multiplexing systems and found no artifacts in the systems that had complete data. Sensitivity increased significantly with multiplexing but we found only small, nonsignificant differences in contrast-to-noise ratio. However, the NPW-SNR did slightly improve in the multiplexing setups. We conclude that more multiplexing does not necessarily result in more artifacts and that even a high amount of multiplexing can still result in artifact-free images if the nonmultiplexed data is complete or when the overlap can be sufficiently de-multiplexed.
引用
收藏
页码:474 / 486
页数:13
相关论文
共 50 条
  • [31] Image Reconstructions from Limit Views and Angle Coverage Data for a Stationary Multi-Pinhole SPECT System
    HSIEH Hohui
    HSIAO Ingtsung
    [J]. Tsinghua Science and Technology, 2010, 15 (01) : 44 - 49
  • [32] Correction of multiplexing artefacts in multi-pinhole SPECT through temporal shuttering, de-multiplexing of projections, and alternating reconstruction
    Pells, Sophia
    Zeraatkar, Navid
    Kalluri, Kesava S.
    Moore, Stephen C.
    May, Micaehla
    Furenlid, Lars R.
    Kupinski, Matthew A.
    Kuo, Phillip H.
    King, Michael A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (12):
  • [33] Design of an Optimized Multi-pinhole Collimator for Brain SPECT
    Chen, L.
    Mok, G. S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S212 - S212
  • [34] Performance evaluation of a clinical multi-pinhole brain SPECT system: comparison with a conventional SPECT system
    Thilsing-Hansen, Kasper
    Simonsen, Jane
    Hvidsten, Svend
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [35] Position-dependent noise in multi-pinhole SPECT
    Cuddy-Walsh, Sarah
    Wells, R. Glenn
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [36] Multi-pinhole SPECT for small animal research.
    Schramm, NU
    Engeland, U
    Ebel, G
    Schurrat, T
    Behe, M
    Behr, TM
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 223P - 223P
  • [37] Multi-Pinhole SPECT Imaging With Silicon Strip Detectors
    Peterson, Todd E.
    Shokouhi, Sepideh
    Furenlid, Lars R.
    Wilson, Donald W.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 646 - 652
  • [38] Theoretical Bounds and Optimal Configurations for Multi-Pinhole SPECT
    Nillius, Peter
    Danielsson, Mats
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4286 - 4288
  • [39] A simulation study for SPECT multi-pinhole detector optimization
    Min, Byung Jun
    Choi, Yong
    Joung, Jinhun
    Lee, Nam Yong
    Song, Tae Yong
    Jung, Jin Ho
    Hong, Key Jo
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2228 - 2231
  • [40] Geometric characterization of multi-axis multi-pinhole SPECT
    DiFilippo, Frank P.
    [J]. MEDICAL PHYSICS, 2008, 35 (01) : 181 - 194