Calculation of the effective dose and its variation from environmental gamma ray sources

被引:47
|
作者
Saito, K
Petoussi-Henss, N
Zankl, M
机构
[1] Japan Atom Energy Res Inst, Tokai, Ibaraki 31911, Japan
[2] GSF, Natl Res Ctr Environm & Hlth, Inst Radiat Protect, D-85764 Neuherberg, Germany
来源
HEALTH PHYSICS | 1998年 / 74卷 / 06期
关键词
effective dose; dose equivalent; effective; gamma radiation; Monte Carlo;
D O I
10.1097/00004032-199806000-00007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Effective dose, an indicator of the stochastic effect of radiation, has been widely used in dose evaluation in the environment. Though conversion factors have been used to obtain E from the air kerma or air absorbed dose, the variation of the conversion factors due to the change of exposure conditions has not been sufficiently investigated. This report documents an investigation of the variation of the effective dose per air kerma for environmental gamma rays depending on the exposure conditions using anthropomorphic phantoms and Monte Carlo calculations, taking into account the precise angular and energy distributions of the environmental gamma rays incident on the human body. As causes of the variation, posture of human bodies, biases of environmental source distributions, and body size were considered. The variation of effective dose in a prone position compared with that in a standing position was found to be within 30%, The bias of environmental sources causes the effective dose per air kerma to vary by 20% at maximum, but in some cases for low-energy gamma rays the variation was found to be up to 40% due to the change in the energy spectrum, The effective dose for a new born infant was estimated to be higher than that for an adult by a maximum of 80-90% for low-energy gamma rays from anthropogenic sources because of a lower shielding effect of the smaller body. The variation of the effective dose equivalent shows a similar tendency to the effective dose. Consequently, this study made it possible to estimate the uncertainties of effective dose and effective dose equivalent evaluated from air kerma or absorbed dose in air using the standard available conversion factors.
引用
收藏
页码:698 / 706
页数:9
相关论文
共 50 条
  • [31] ACCURACY OF THE DOSE CALIBRATOR FOR EXPOSURE CALIBRATION OF GAMMA-RAY BRACHYTHERAPY SOURCES
    WILLIAMSON, JF
    KHAN, FM
    MEDICAL PHYSICS, 1981, 8 (04) : 571 - 571
  • [32] A Light and Effective Wide Field Monitor for Gamma Ray Bursts and Transient Sources
    Feroci, M.
    Amati, L.
    Antonelli, L. A.
    Bonvicini, V.
    Campana, R.
    Costa, E.
    Del Monte, E.
    Donnarumma, I.
    Evangelista, Y.
    Fiore, F.
    Fuschino, F.
    Israel, G. L.
    Labanti, C.
    Lapshov, I.
    Lazzarotto, F.
    Marisaldi, M.
    Mastropietro, M.
    Morelli, E.
    Muleri, F.
    Nicastro, F.
    Orlandini, M.
    Pacciani, L.
    Perotti, F.
    Rapisarda, M.
    Rashevsky, A.
    Rubini, A.
    Soffitta, P.
    Vacchi, A.
    Zampa, G.
    Zampa, N.
    GAMMA-RAY BUSTS, 2009, 1133 : 49 - +
  • [33] Effective dose equivalent and effective dose for photon exposures from point and disk sources on the floor
    Kim, CH
    Reece, WD
    Poston, JW
    HEALTH PHYSICS, 1998, 75 (02): : 170 - 178
  • [34] CALCULATION OF RELIABILITY OF RADIATION-CHEMICAL INSTALLATIONS CONTAINING GAMMA-RAY SOURCES
    KOZLOV, YD
    FILARETO.LG
    ATOMNAYA ENERGIYA, 1973, 34 (01): : 31 - 31
  • [35] Gamma-Ray Dose From an Overhead Plume
    McNaughton, Michael W.
    Gillis, Jessica M.
    Ruedig, Elizabeth
    Whicker, Jeffrey J.
    Fuehne, David P.
    HEALTH PHYSICS, 2017, 112 (05): : 445 - 450
  • [36] CALCULATION OF RADIATION DOSE FROM THOROTRAST USING WHOLE-BODY GAMMA-RAY SPECTRAL DATA
    COHN, SH
    GUSMANO, EA
    ROBERTSON, JS
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1967, 145 (A3) : 608 - +
  • [37] Calculation of the ambient dose equivalent H*(10) from gamma-ray spectra obtained with scintillation detectors
    Casanovas, Ramon
    Prieto, Elena
    Salvado, Marcal
    APPLIED RADIATION AND ISOTOPES, 2016, 118 : 154 - 159
  • [38] GAMMA-DOSE FROM VOLUME SOURCES BY A SIMPLE EQUATION
    DEGANGI, NL
    HODGDON, AD
    BARTLETT, EB
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1985, 50 (NOV): : 449 - 450
  • [39] MEASURING DOSE RATES OF NATURAL ENVIRONMENTAL RADIATION BY GAMMA-RAY-SPECTROMETRY
    KEIL, A
    RAJEWSKY, B
    ATOMPRAXIS, 1966, 12 (11): : 579 - &
  • [40] Effective dose equivalent for point gamma sources located 10 cm near the body
    Xu, X. George
    Bushart, Sean
    Anderson, Ralph
    HEALTH PHYSICS, 2006, 91 (02): : 108 - 118