Calculation of the effective dose and its variation from environmental gamma ray sources

被引:47
|
作者
Saito, K
Petoussi-Henss, N
Zankl, M
机构
[1] Japan Atom Energy Res Inst, Tokai, Ibaraki 31911, Japan
[2] GSF, Natl Res Ctr Environm & Hlth, Inst Radiat Protect, D-85764 Neuherberg, Germany
来源
HEALTH PHYSICS | 1998年 / 74卷 / 06期
关键词
effective dose; dose equivalent; effective; gamma radiation; Monte Carlo;
D O I
10.1097/00004032-199806000-00007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Effective dose, an indicator of the stochastic effect of radiation, has been widely used in dose evaluation in the environment. Though conversion factors have been used to obtain E from the air kerma or air absorbed dose, the variation of the conversion factors due to the change of exposure conditions has not been sufficiently investigated. This report documents an investigation of the variation of the effective dose per air kerma for environmental gamma rays depending on the exposure conditions using anthropomorphic phantoms and Monte Carlo calculations, taking into account the precise angular and energy distributions of the environmental gamma rays incident on the human body. As causes of the variation, posture of human bodies, biases of environmental source distributions, and body size were considered. The variation of effective dose in a prone position compared with that in a standing position was found to be within 30%, The bias of environmental sources causes the effective dose per air kerma to vary by 20% at maximum, but in some cases for low-energy gamma rays the variation was found to be up to 40% due to the change in the energy spectrum, The effective dose for a new born infant was estimated to be higher than that for an adult by a maximum of 80-90% for low-energy gamma rays from anthropogenic sources because of a lower shielding effect of the smaller body. The variation of the effective dose equivalent shows a similar tendency to the effective dose. Consequently, this study made it possible to estimate the uncertainties of effective dose and effective dose equivalent evaluated from air kerma or absorbed dose in air using the standard available conversion factors.
引用
收藏
页码:698 / 706
页数:9
相关论文
共 50 条
  • [21] A SHAPE AND MESH ADAPTIVE COMPUTATIONAL METHODOLOGY FOR GAMMA-RAY DOSE FROM VOLUMETRIC SOURCES
    MIRZA, NM
    ALI, B
    MIRZA, SM
    TUFAIL, M
    AHMAD, N
    RADIATION PROTECTION DOSIMETRY, 1991, 38 (04) : 307 - 314
  • [22] MEASUREMENT OF AVERAGE GAMMA-RAY DOSE WITH UNIFORMLY DISTRIBUTED SOURCES
    LAHMANN, W
    HINZPETER, A
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1976, 27 (03): : 137 - 141
  • [23] NEW METHOD FOR COMPUTER GENERATION OF DOSE DISTRIBUTIONS FROM EXTERNAL X-RAY AND GAMMA-RAY SOURCES
    THAMES, HD
    RADIOLOGY, 1973, 106 (01) : 199 - 208
  • [24] CALCULATION OF RADIATION DOSE FROM DISTRIBUTED SOURCES OF TRITIUM
    STEWART, FS
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY AND RELATED STUDIES IN PHYSICS CHEMISTRY AND MEDICINE, 1964, 8 (06): : 545 - +
  • [25] THE CALCULATION OF DOSE FROM POINT AND LINEAR SOURCES OF RADIUM
    SILVERSTONE, SM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1946, 55 (02) : 203 - 211
  • [26] Radioactivity measurement and dose rate calculation due to gamma-ray of soil from Chashnikovo - Russia
    Badawy, W. M.
    Mamikhin, S. V.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2012, 45 (02): : 270 - 282
  • [27] CALCULATION OF gamma -RAY BACKSCATTERING FROM AN INTERFACE.
    Serebrennikov, I.Ya.
    Soviet Journal of Nondestructive Testing (English translation of Defektoskopiya), 1976, 12 (03): : 278 - 283
  • [28] Environmental gamma-ray dose rate in Aomori Prefecture, Japan
    Iyogi, T
    Ueda, S
    Hisamatsu, S
    Kondo, K
    Haruta, H
    Katagiri, H
    Kurabayashi, M
    Nakamura, Y
    Tsuji, N
    HEALTH PHYSICS, 2002, 82 (04): : 521 - 526
  • [29] Constraints from undetected gamma-ray sources
    Fichtel, CE
    Sreekumar, P
    PROCEEDINGS OF THE FOURTH COMPTON SYMPOSIUM, PTS 1 AND 2: PT 1: THE COMPTON OBSERVATORY IN REVIEW; PT 2: PAPERS AND PRESENTATIONS, 1997, (410): : 436 - 446
  • [30] PLASTIC EFFECT - QUENCH MONITORING VARIATION WITH DIFFERENT GAMMA-RAY SOURCES
    HORROCKS, DL
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1976, 27 (07): : 369 - 372