Comparison of Flow Estimators for Rotary Blood Pumps: An In Vitro and In Vivo Study

被引:14
|
作者
Petrou, Anastasios [1 ]
Kuster, Daniel [1 ]
Lee, Jongseok [2 ]
Meboldt, Mirko [1 ]
Daners, Marianne Schmid [1 ]
机构
[1] Swiss Fed Inst Technol, Prod Dev Grp Zurich, Dept Mech & Proc Engn, CH-8092 Zurich, Switzerland
[2] German Aerosp Ctr DLR, Inst Robot & Mechatron, D-82234 Wessling, Germany
关键词
Ventricular assist device; Numerical model of cardiovascular system; Physiological control; Monitoring; Extended Kalman filter; Pressure sensor; VENTRICULAR ASSIST DEVICES; PRESSURE-HEAD; DIFFERENTIAL PRESSURE; SYSTEM; POWER;
D O I
10.1007/s10439-018-2106-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Various approaches for estimating the flow rate of a rotary blood pump have been proposed for monitoring and control purposes. They have been evaluated under different test conditions and, therefore, a direct comparisonamong them is difficult. Furthermore, a limited performance has been reported for the areas where the pump flow and motor current present a non-monotonic relationship. In this regard, we selected most approaches that have been presented in literature and added a modified one, resulting in four estimators, which are either non-invasive or invasive, i.e., inlet and outlet pump pressure sensors are used. Data from in vitro and in vivo studies with the Deltastream pump DP2 were used to compare the estimators under the same test conditions. These data included both constant and varying pre- and afterload, contractility, viscosity, as well as pump speed settings. Bland-Altman plots were used to evaluate the performance of the estimators. The mean error of the overall estimated flow in vitro ranged from 0.002 to 0.38L/min and the limits of agreement (LoA) between +/- 2L/min. During negative flows the mean error decreased by about 25% when the pump inlet pressure was addedas an input. In vivo, the mean errors increased, while the LoA remained in the same range. An estimator based on pump pressure difference improves the reliability in areas where flow and current relationship is not monotonic. A trade-off between estimation accuracy and number of sensors was identified. The estimation objective and the potential errors should be considered when selecting an estimation approach and designing the pump systems.
引用
收藏
页码:2123 / 2134
页数:12
相关论文
共 50 条
  • [1] Comparison of Flow Estimators for Rotary Blood Pumps: An In Vitro and In Vivo Study
    Anastasios Petrou
    Daniel Kuster
    Jongseok Lee
    Mirko Meboldt
    Marianne Schmid Daners
    Annals of Biomedical Engineering, 2018, 46 : 2123 - 2134
  • [2] Correction to: Comparison of Flow Estimators for Rotary Blood Pumps: An In Vitro and In Vivo Study
    Anastasios Petrou
    Daniel Kuster
    Jongseok Lee
    Mirko Meboldt
    Marianne Schmid Daners
    Annals of Biomedical Engineering, 2019, 47 : 1827 - 1827
  • [3] Comparison of Flow Estimators for Rotary Blood Pumps: An In Vitro and In Vivo Study (vol 46, pg 2123, 2018)
    Petrou, Anastasios
    Kuster, Daniel
    Lee, Jongseok
    Meboldt, Mirko
    Daners, Marianne Schmid
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (08) : 1827 - 1827
  • [4] Standardized Comparison of Selected Physiological Controllers for Rotary Blood Pumps: In Vitro Study
    Petrou, Anastasios
    Lee, Jongseok
    Dual, Seraina
    Ochsner, Gregor
    Meboldt, Mirko
    Daners, Marianne Schmid
    ARTIFICIAL ORGANS, 2018, 42 (03) : E29 - E42
  • [5] IN VITRO AND IN VIVO FLOW STUDIES IN BLOOD PUMPS
    LIOTTA, D
    WIETING, DW
    HALL, CW
    GHIDONI, JJ
    DEBAKEY, ME
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1967, 13 (APR): : 280 - &
  • [6] Physiologic control of rotary blood pumps:: An in vitro study
    Giridharan, GA
    Pantalos, GM
    Gillars, KJ
    Koenig, SC
    Skliar, M
    ASAIO JOURNAL, 2004, 50 (05) : 403 - 409
  • [7] Mathematical Modeling of Rotary Blood Pumps in a Pulsatile In Vitro Flow Environment
    Pirbodaghi, Tohid
    ARTIFICIAL ORGANS, 2017, 41 (08) : 710 - 716
  • [8] In vitro thrombogenicity evaluation of rotary blood pumps by thromboelastometry
    Klein, Mario
    Tack, Jana Christine
    Mager, Ilona
    Maas, Judith
    Schmitz-Rode, Thomas
    Arens, Jutta
    Steinseifer, Ulrich
    Clauser, Johanna Charlotte
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2022, 67 (06): : 471 - 480
  • [9] Electrodynamics of Axial-Flow Rotary Blood Pumps
    Nesterenko, Igor, V
    Pugovkin, Alexander A.
    Leonhardt, Steffen
    Walter, Marian
    Borchers, Patrick
    Markov, Aleksandr
    Karimov, Jamshid H.
    Selishchev, Sergey, V
    Telyshev, Dmitry, V
    IEEE ACCESS, 2021, 9 (09): : 164700 - 164711
  • [10] In-Vitro Evaluation of Cardiac Energetics and Coronary Flow with Volume Displacement and Rotary Blood Pumps
    Wu, Eric L.
    Tansley, Geoff
    Fraser, John F.
    Gregory, Shaun D.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5277 - 5281