Reproducibility of magnetic resonance spectroscopy in correlation with signal-to-noise ratio

被引:15
|
作者
Okada, Tomohisa
Sakamoto, Setsu
Nakamoto, Yuji
Kohara, Nobuo
Senda, Michio
机构
[1] Kyoto Univ, Dept Diagnost Radiol, Sakyo Ku, Kyoto 6068507, Japan
[2] Inst Biomed Res & Innovat, Dept Mol Imaging, Kobe, Hyogo 6500047, Japan
[3] Kobe City Gen Hosp, Dept Neurol, Kobe, Hyogo 6500046, Japan
基金
日本学术振兴会;
关键词
magnetic resonance spectroscopy; myoinositol; Alzheimer's disease; reproducibility; signal-to-noise ratio;
D O I
10.1016/j.pscychresns.2007.03.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
An increased amount of myoinositol (mI) relative to creatine (Cr) by proton MR spectroscopy (H-1-MRS) measurement gives a useful aid for the diagnosis of Alzheimer's disease (AD). Previous results of test-retest measurement of mI, however, have shown variability more than twice as large as for other metabolites. The aims of this study were to analyze test-retest variability of H-1-MRS measurements in correlation with signal-to-noise ratio (SNR). Ten subjects clinically suspected of mild AD were examined twice (2-14 days apart) with H-1-MRS measurements of voxels placed at anterior and posterior cingulate cortex. The percent differences between two measurements (%differences) of mI/Cr showed a significant linear trend to decrease as average SNR increased, but %differences of N-acetylaspartate (NAA)/Cr and choline (Cho)/Cr did not. The average of %differences was 10.5, 15.0 and 20.8 for NAA/Cr, Cho/Cr, and mI/Cr, respectively, indicating a prominent deterioration of mI/Cr measurement reproducibility, which decreased to 6.96, 15.4 and 9.87, respectively, when the analysis was limited to measurements with SNR over 25. The results indicate that MRS measurements with high SNR should be used to obtain reliable assessments of mI/Cr as accurate diagnostic indicator of AD in clinical MR examinations. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 50 条
  • [31] Optimized radiofrequency coils for increased signal-to-noise ratio in magnetic resonance microscopy
    Hurlston, SE
    Cofer, GP
    Johnson, GA
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1997, 8 (03) : 277 - 284
  • [32] Adaptive template filtering for signal-to-noise ratio enhancement in magnetic resonance imaging
    Ahn, CB
    Song, YC
    Park, DJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (06) : 549 - 556
  • [33] Computation of the signal-to-noise ratio of high-frequency magnetic resonance imagers
    Kowalski, ME
    Jin, JM
    Chen, J
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (11) : 1525 - 1533
  • [34] SIGNAL-TO-NOISE RATIO OF THE TWIN-T NUCLEAR MAGNETIC RESONANCE BRIDGE
    GHEORGHIU, D
    VALERIU, A
    NUCLEAR INSTRUMENTS & METHODS, 1962, 16 (03): : 313 - 316
  • [35] Signal-to-noise ratio evaluation of magnetic resonance images in the presence of an ultrasonic motor
    Peyman Shokrollahi
    James M. Drake
    Andrew A. Goldenberg
    BioMedical Engineering OnLine, 16
  • [36] Adaptive template filtering for signal-to-noise ratio enhancement in magnetic resonance imaging
    Department of Electrical Engineering, Kwangwoon University, Taejon, Korea, Republic of
    不详
    IEEE Trans. Med. Imaging, 6 (549-556):
  • [37] Signal-to-noise ratio of spin noise spectroscopy in rubidium vapor
    Ping, Shi
    Jian, Ma
    Xuan, Qian
    Yang, Ji
    Wei, Li
    ACTA PHYSICA SINICA, 2017, 66 (01)
  • [38] Signal-to-noise ratio in chirped laser dispersion spectroscopy
    Nikodem, Michal
    Weidmann, Damien
    Smith, Clinton
    Wysocki, Gerard
    OPTICS EXPRESS, 2012, 20 (01): : 644 - 653
  • [39] Analysis of signal-to-noise ratio of spatial heterodyne spectroscopy
    Wang, Qiansheng
    Luo, Haiyan
    Li, Zhiwei
    Ding, Yi
    Xiong, Wei
    MEASUREMENT, 2024, 237
  • [40] Analysis of signal-to-noise ratio of polynomial correlation filters
    Al-Mashouq, K
    Kumar, BVKV
    Alkanhal, M
    OPTICAL PATTERN RECOGNITION X, 1999, 3715 : 407 - 413