Reproducibility of magnetic resonance spectroscopy in correlation with signal-to-noise ratio

被引:15
|
作者
Okada, Tomohisa
Sakamoto, Setsu
Nakamoto, Yuji
Kohara, Nobuo
Senda, Michio
机构
[1] Kyoto Univ, Dept Diagnost Radiol, Sakyo Ku, Kyoto 6068507, Japan
[2] Inst Biomed Res & Innovat, Dept Mol Imaging, Kobe, Hyogo 6500047, Japan
[3] Kobe City Gen Hosp, Dept Neurol, Kobe, Hyogo 6500046, Japan
基金
日本学术振兴会;
关键词
magnetic resonance spectroscopy; myoinositol; Alzheimer's disease; reproducibility; signal-to-noise ratio;
D O I
10.1016/j.pscychresns.2007.03.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
An increased amount of myoinositol (mI) relative to creatine (Cr) by proton MR spectroscopy (H-1-MRS) measurement gives a useful aid for the diagnosis of Alzheimer's disease (AD). Previous results of test-retest measurement of mI, however, have shown variability more than twice as large as for other metabolites. The aims of this study were to analyze test-retest variability of H-1-MRS measurements in correlation with signal-to-noise ratio (SNR). Ten subjects clinically suspected of mild AD were examined twice (2-14 days apart) with H-1-MRS measurements of voxels placed at anterior and posterior cingulate cortex. The percent differences between two measurements (%differences) of mI/Cr showed a significant linear trend to decrease as average SNR increased, but %differences of N-acetylaspartate (NAA)/Cr and choline (Cho)/Cr did not. The average of %differences was 10.5, 15.0 and 20.8 for NAA/Cr, Cho/Cr, and mI/Cr, respectively, indicating a prominent deterioration of mI/Cr measurement reproducibility, which decreased to 6.96, 15.4 and 9.87, respectively, when the analysis was limited to measurements with SNR over 25. The results indicate that MRS measurements with high SNR should be used to obtain reliable assessments of mI/Cr as accurate diagnostic indicator of AD in clinical MR examinations. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 50 条
  • [21] THE OUTPUT SIGNAL-TO-NOISE RATIO OF CORRELATION DETECTORS
    GREEN, PE
    IRE TRANSACTIONS ON INFORMATION THEORY, 1957, 3 (01): : 10 - 18
  • [22] SIGNAL-TO-NOISE RATIO FOR A PHOTOCOUNT CORRELATION EXPERIMENT
    PUSEY, PN
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (01): : 62 - &
  • [23] Optimization of the signal-to-noise ratio for photoreflectance spectroscopy
    Behn, U
    Thamm, A
    Brandt, O
    Grahn, HT
    JOURNAL OF APPLIED PHYSICS, 2001, 90 (10) : 5081 - 5085
  • [24] NMR spectroscopy threshold signal-to-noise ratio
    Kolar, Petar
    Blazok, Lovro
    Bojanjac, Dario
    TM-TECHNISCHES MESSEN, 2021, 88 (09) : 571 - 580
  • [26] Optimizing the signal-to-noise ratio for X-ray photon correlation spectroscopy
    Falus, P
    Lurio, LB
    Mochrie, SGJ
    JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 : 253 - 259
  • [27] Increase the Signal-to-Noise Ratio of Magnetic Resonance Imaging by a Vertical Coil Array
    Liang, Dandan
    Hui, Hon Tat
    Yeo, Tat Soon
    2012 IEEE ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP), 2012, : 311 - 312
  • [28] Quantification and improvement of the signal-to-noise ratio in a magnetic resonance image acquisition procedure
    Sijbers, J
    Scheunders, P
    Bonnet, N
    VanDyck, D
    Raman, E
    MAGNETIC RESONANCE IMAGING, 1996, 14 (10) : 1157 - 1163
  • [29] Signal-to-noise ratio evaluation of magnetic resonance images in the presence of an ultrasonic motor
    Shokrollahi, Peyman
    Drake, James M.
    Goldenberg, Andrew A.
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [30] MAGNETIC RECORDING STANDARDS AND SIGNAL-TO-NOISE RATIO
    PIEPLOW, H