Reproducibility of magnetic resonance spectroscopy in correlation with signal-to-noise ratio

被引:15
|
作者
Okada, Tomohisa
Sakamoto, Setsu
Nakamoto, Yuji
Kohara, Nobuo
Senda, Michio
机构
[1] Kyoto Univ, Dept Diagnost Radiol, Sakyo Ku, Kyoto 6068507, Japan
[2] Inst Biomed Res & Innovat, Dept Mol Imaging, Kobe, Hyogo 6500047, Japan
[3] Kobe City Gen Hosp, Dept Neurol, Kobe, Hyogo 6500046, Japan
基金
日本学术振兴会;
关键词
magnetic resonance spectroscopy; myoinositol; Alzheimer's disease; reproducibility; signal-to-noise ratio;
D O I
10.1016/j.pscychresns.2007.03.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
An increased amount of myoinositol (mI) relative to creatine (Cr) by proton MR spectroscopy (H-1-MRS) measurement gives a useful aid for the diagnosis of Alzheimer's disease (AD). Previous results of test-retest measurement of mI, however, have shown variability more than twice as large as for other metabolites. The aims of this study were to analyze test-retest variability of H-1-MRS measurements in correlation with signal-to-noise ratio (SNR). Ten subjects clinically suspected of mild AD were examined twice (2-14 days apart) with H-1-MRS measurements of voxels placed at anterior and posterior cingulate cortex. The percent differences between two measurements (%differences) of mI/Cr showed a significant linear trend to decrease as average SNR increased, but %differences of N-acetylaspartate (NAA)/Cr and choline (Cho)/Cr did not. The average of %differences was 10.5, 15.0 and 20.8 for NAA/Cr, Cho/Cr, and mI/Cr, respectively, indicating a prominent deterioration of mI/Cr measurement reproducibility, which decreased to 6.96, 15.4 and 9.87, respectively, when the analysis was limited to measurements with SNR over 25. The results indicate that MRS measurements with high SNR should be used to obtain reliable assessments of mI/Cr as accurate diagnostic indicator of AD in clinical MR examinations. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 50 条
  • [1] The signal-to-noise ratio of the nuclear magnetic resonance experiment
    Hoult D.I.
    Richards R.E.
    [J]. Journal of Magnetic Resonance, 2011, 213 (02) : 329 - 343
  • [2] Improvement of signal-to-noise ratio in magnetic resonance image
    Guo, Yang
    Zhang, Jiwu
    Zhang, Xiangde
    Zheng, Quanlu
    [J]. Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2002, 19 (03): : 493 - 495
  • [3] SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT
    HOULT, DI
    RICHARDS, RE
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) : 71 - 85
  • [4] A Method for Evaluating the Signal-to-Noise Ratio in Magnetic Resonance Images
    K. A. Sergunova
    E. S. Akhmad
    N. N. Potrakhov
    [J]. Biomedical Engineering, 2019, 53 : 207 - 210
  • [5] A Method for Evaluating the Signal-to-Noise Ratio in Magnetic Resonance Images
    Sergunova, K. A.
    Akhmad, E. S.
    Potrakhov, N. N.
    [J]. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2019, 53 (03): : 207 - 210
  • [6] SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC RESONANCE OSCILLATOR SPECTROMETERS
    SMITH, MR
    HUGHES, DG
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1971, 4 (10): : 725 - &
  • [7] Measuring the signal-to-noise ratio in magnetic resonance imaging: a caveat
    Erdogmus, D
    Larsson, EG
    Yan, R
    Principe, JC
    Fitzsimmons, JR
    [J]. SIGNAL PROCESSING, 2004, 84 (06) : 1035 - 1040
  • [8] Signal-to-noise ratio in stochastic resonance
    Chattah, AK
    Briozzo, CB
    Osenda, O
    Caceres, MO
    [J]. MODERN PHYSICS LETTERS B, 1996, 10 (22): : 1085 - 1094
  • [9] SIGNAL-TO-NOISE RATIO IN FOURIER SPECTROSCOPY
    TREFFERS, RR
    [J]. APPLIED OPTICS, 1977, 16 (12): : 3103 - 3106
  • [10] A Novel Approach To Signal-To-Noise Ratio Improvement Of Magnetic Resonance Phased Array Spectroscopy Signals
    Martini, N.
    Santarelli, M. F.
    Milanesi, M.
    Giovannetti, G.
    Positano, V
    Vanello, N.
    Landini, L.
    [J]. ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2008, : 257 - 260