Galloping experimental analysis of conductors covered with a D-section on a high-voltage overhead test line

被引:0
|
作者
Van Dyke, Pierre [1 ]
Laneville, Andre [1 ]
Bouchard, Dave [1 ]
机构
[1] Hydro Quebec IREQ, Varennes, PQ, Canada
来源
PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE VOL 9 | 2007年
关键词
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
This paper presents galloping measurements conducted on a high-voltage overhead test line equipped with three single conductors as well as a second configuration of three conductors interconnected with interphase spacers. The test line consists of three suspension spans and two dead-end spans. To induce galloping amplitudes typical of those encountered as ice is formed on the conductor, a D-section jacketing was added to the conductors in the middle span. Conductor displacement was monitored using two accelerometers on each conductor and two video cameras. Different factors potentially influencing galloping amplitude, such as the mode that is excited, conductor tension, D-section mass per unit length and the wind's angle of attack have been looked at.
引用
收藏
页码:891 / 898
页数:8
相关论文
共 50 条
  • [41] Fretting Wear Behaviors of Aluminum Cable Steel Reinforced (ACSR) Conductors in High-Voltage Transmission Line
    Ma, Xingchi
    Gao, Lei
    Zhang, Junxi
    Zhang, Lai-Chang
    METALS, 2017, 7 (09)
  • [42] Experimental Analysis of Temperature Distribution in High-Voltage Strain Clamp
    Dong, Xuanchang
    Qu, Fengrui
    Li, Yanfei
    Fang, Baili
    Wang, Yiqing
    Liu, Gang
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 829 - 832
  • [43] Line Lightning Protection Device Analysis for 70 kV High Voltage Overhead Line in Malang
    Cahya, Vanny Fitria
    Zoro, Reynaldo
    PROCEEDING OF 2019 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS (ICEEI), 2019, : 666 - 671
  • [44] Visual significance as a factor influencing perceived risks: cost-effectiveness analysis for overhead high-voltage power-line redesign
    Lopez-Rodriguez, Alicia
    Escribano-Bombin, Rafael
    IMPACT ASSESSMENT AND PROJECT APPRAISAL, 2013, 31 (04) : 291 - 304
  • [45] Frequency characteristics measurement of overhead high-voltage power-line in low radio-frequency range
    Zajc, M.
    Suljanovic, N.
    Mujcic, A.
    Tasic, J. F.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2142 - 2149
  • [46] Optimisation design of real-time wireless power supply system overhead high-voltage power line
    Wang, Wei
    Zhu, Zhongbin
    Wang, Qi
    Hu, Minqiang
    IET ELECTRIC POWER APPLICATIONS, 2019, 13 (02) : 206 - 214
  • [47] The Effect of Electromagnetic Environment of High-voltage Transmission Line and ubstations on Electronic Equipment Test
    Wu Jinliang
    Su Donglin
    Li Hongling
    ISAPE 2008: THE 8TH INTERNATIONAL SYMPOSIUM ON ANTENNAS, PROPAGATION AND EM THEORY, PROCEEDINGS, VOLS 1-3, 2008, : 1214 - +
  • [48] A 60 GHZ PULSE RADAR FOR RADAR CROSS-SECTION MEASUREMENT OF HIGH-VOLTAGE OVERHEAD TRANSMISSION-LINES
    BISCHOFF, M
    REMBOLD, B
    WIPPICH, HG
    1981, 54 (4-5): : 172 - 176
  • [49] 60 GHz Pulse Radar for Radar Cross-section Measurement of High-voltage Overhead Transmission Lines.
    Bischoff, Michael
    Rembold, Bernhard
    Wippich, Heinz Georg
    Wissenschaftliche Berichte - AEG-Telefunken, 1981, 54 (4-5): : 172 - 176
  • [50] Analysis of the Performance for Integrated Test of High-Voltage Submersible Motor and Pump
    Zhang Xinfang
    TECHNOLOGY AND APPLICATION OF ELECTRONIC INFORMATION, 2009, : 145 - 148