Galloping experimental analysis of conductors covered with a D-section on a high-voltage overhead test line

被引:0
|
作者
Van Dyke, Pierre [1 ]
Laneville, Andre [1 ]
Bouchard, Dave [1 ]
机构
[1] Hydro Quebec IREQ, Varennes, PQ, Canada
来源
PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE VOL 9 | 2007年
关键词
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
This paper presents galloping measurements conducted on a high-voltage overhead test line equipped with three single conductors as well as a second configuration of three conductors interconnected with interphase spacers. The test line consists of three suspension spans and two dead-end spans. To induce galloping amplitudes typical of those encountered as ice is formed on the conductor, a D-section jacketing was added to the conductors in the middle span. Conductor displacement was monitored using two accelerometers on each conductor and two video cameras. Different factors potentially influencing galloping amplitude, such as the mode that is excited, conductor tension, D-section mass per unit length and the wind's angle of attack have been looked at.
引用
收藏
页码:891 / 898
页数:8
相关论文
共 50 条
  • [32] Research on adaptive reclosing scheme for overhead-submarine hybrid high-voltage transmission line
    Zhang Y.
    Fang S.
    Guo J.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (16): : 115 - 121
  • [33] Terna's experience in avoiding snow and ice sleeves formation on High Voltage overhead line conductors
    Poli, Michele
    Pascucci, Antonio
    Carlini, Enrico Maria
    Buora, Giacomo
    Michi, Luigi
    2019 AEIT INTERNATIONAL ANNUAL CONFERENCE (AEIT), 111TH EDITION, 2019,
  • [34] Bidirectional LSTM Based Partial Discharge Pattern Analysis for Fault Detection in Medium Voltage Overhead Lines with Covered Conductors
    Ahmad, Dilshad
    Wang, Shaorong
    2020 IEEE 18TH INTERNATIONAL CONFERENCE ON INDUSTRIAL INFORMATICS (INDIN), VOL 1, 2020, : 70 - 73
  • [35] Determination of phase sequence and voltage level of high-voltage double-circuit overhead conductors using non-contact technique
    Li, F.
    Moore, P. J.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 2137 - +
  • [36] STATISTICAL-ANALYSIS OF A HIGH-VOLTAGE ENDURANCE TEST ON AN EPOXY
    STONE, GC
    KURTZ, M
    VANHEESWIJK, RG
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1979, 14 (06): : 315 - 326
  • [37] Wind Load of High Voltage Overhead Transmission Line Conductors in Field Measurements, Time Domain Simulations and Standard
    Stengel, Dominik
    Mehdianpour, Milad
    STAHLBAU, 2017, 86 (01) : 45 - 53
  • [38] EXPERIMENTAL INVESTIGATIONS OF CORONA-INDUCED VIBRATION ON HIGH-VOLTAGE CONDUCTORS WITH DIFFERENT TYPES OF SUPPORTS
    PHAN, LC
    ADACHI, T
    ALLAIRE, MA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04): : 1975 - 1985
  • [39] Simulation analysis of the impact of the deployment of conductors of high-voltage line 110 kV on the accuracy measurement of current using interferometric sensor
    Torbus, Slawomir Andrzej
    Jordan, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (06): : 275 - 278
  • [40] Damage investigation of the aged aluminium cable steel reinforced (ACSR) conductors in a high-voltage transmission line
    Chen, Guohong
    Wang, Xu
    Wang, Jiaqing
    Liu, Junjian
    Zhang, Tao
    Tang, Wenming
    ENGINEERING FAILURE ANALYSIS, 2012, 19 : 13 - 21