Nanoporous gold-based microbial biosensor for direct determination of sulfide

被引:43
|
作者
Liu, Zhuang [1 ]
Ma, Hanyue [1 ]
Sun, Huihui [1 ]
Gao, Rui [1 ]
Liu, Honglei [1 ]
Wang, Xia [1 ]
Xu, Ping [1 ,2 ,3 ]
Xun, Luying [1 ]
机构
[1] Shandong Univ, State Key Lab Microbial Technol, Jinan 250100, Shandong, Peoples R China
[2] Shanghai Jiao Tong Univ, Key Lab Microbial Metab, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Life Sci & Biotechnol, Shanghai 200240, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Sulfide:quinone oxidoreductase; Nanoporous gold; Recombinant E. coil BL21; Microbial biosensor; Sulfide; HYDROGEN-SULFIDE; HORSERADISH-PEROXIDASE; OXIDIZING BACTERIA; GLUCOSE-OXIDASE; ELECTRODE; INHIBITION; H2S; NANOPARTICLES; SPECTROSCOPY; PERFORMANCE;
D O I
10.1016/j.bios.2017.06.037
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Environmental pollution caused by sulfide compounds has become a major problem for public health. Hence, there is an urgent need to explore a sensitive, selective, and simple sulfide detection method for environmental monitoring and protection. Here, a novel microbial biosensor was developed using recombinant Escherichia coil BL21 (E. coil BL21) expressing sulfide;quinone oxidoreductase (SQR) for sulfide detection. As an important enzyme involved in the initial step of sulfide metabolism, SQR oxidizes sulfides to polysulfides and transfers electrons to the electron transport chain. Nanoporous gold (NPG) with its unique properties was selected for recombinant E. coil BL21 cells immobilization, and then glassy carbon electrode (GCE) was modified by the resulting E. coli/NPG biocomposites to construct an E. coli/NPG/GCE bioelectrode. Due to the catalytic oxidation properties of NPG for sulfide, the electrochemical reaction of the E. coli/NPG/GCE bioelectrode is attributed to the co-catalysis of SQR and NPG. For sulfide detection, the E. coil/NPG/GCE bioelectrode showed a good linear response ranging from 50 mu M to 5 mM, with a high sensitivity of 18.35 mu A mM(-1) cm(-2) and a low detection limit of 2.55 mu M. The anti-interference ability of the E. coli/NPG/GCE bioelectrode is better than that of enzyme-based inhibitive biosensors. Further, the E. coli/NPG/GCE bioelectrode was successfully applied to the detection of sulfide in wastewater. These unique properties potentially make the E. coli/NPG/GCE bioelectrode an excellent choice for reliable sulfide detection.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [41] Shining photocatalysis by gold-based nanomaterials
    Zhu, Haiguang
    Yuan, Xun
    Yao, Qiaofeng
    Xie, Jianping
    NANO ENERGY, 2021, 88
  • [42] Aquaporin inhibition by a gold-based compound
    Martins, A. P.
    Cobo, A. G.
    Echevarria, M.
    Casini, A.
    Soveral, G.
    FEBS JOURNAL, 2012, 279 : 257 - 257
  • [43] An enzyme based biosensor for the direct determination of diisopropyl fluorophosphate
    Simonian, AL
    diSioudi, BD
    Wild, JR
    ANALYTICA CHIMICA ACTA, 1999, 389 (1-3) : 189 - 196
  • [44] Electrochemical biosensor based on nanoporous gold electrode for detection of PML/RARα fusion gene
    Zhong, Guangxian
    Liu, Ailin
    Chen, Xuhai
    Wang, Kun
    Lian, Zhixian
    Liu, Qicai
    Chen, Yuanzhong
    Du, Min
    Lin, Xinhua
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (09): : 3812 - 3817
  • [45] Wear of Electroplated Gold-Based Coatings
    Shugurov, A. R.
    Panin, A. V.
    Lyazgin, A. O.
    Shesterikov, E. V.
    PHYSICAL MESOMECHANICS, 2016, 19 (04) : 407 - 419
  • [46] An electrochemical NADH biosensor based on a nanoporous gold electrode modified with diaphorase and an osmium polymer
    Otero, Fernando
    Mandal, Tanushree
    Leech, Donal
    Magner, Edmond
    SENSORS AND ACTUATORS REPORTS, 2022, 4
  • [47] The Reliable Detection of Homocysteine Using a Biosensor Based on Recombinant Cystathionine β-Synthase and Nanoporous Gold
    Huang, Zihan
    Gao, Yan
    Zhang, Lei
    Cai, Ting
    Liu, Ruijun
    Wang, Xia
    MICROORGANISMS, 2025, 13 (03)
  • [48] Dealloying strategy to fabricate ultrafine nanoporous gold-based alloys with high structural stability and tunable magnetic properties
    Zhang, Zhonghua
    Zhang, Chi
    Gao, Yulai
    Frenzel, Jan
    Sun, Junzhe
    Eggeler, Gunther
    CRYSTENGCOMM, 2012, 14 (23): : 8292 - 8300
  • [49] Gold foil-based biosensor for the determination of hydrogen peroxide
    Narayanan, J. Shankara
    Slaughter, Gymama
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 2885 - 2888
  • [50] Microbial electrode for determination of sulfide
    Wang, X.H.
    Sun, Y.S.
    Wang, Y.R.
    Bai, Z.H.
    Li, X.D.
    Fenxi Yiqi/Analytical Instrumentation, 2001, (01):