Data explosion: the challenge of multidetector-row CT

被引:153
|
作者
Rubin, GD [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
multidetector-row CT; data explosion; 3D workstation;
D O I
10.1016/S0720-048X(00)00270-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-raw CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that same of these future developments might take are discussed. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [41] Evaluation of advancing the standard valve dysfunction by multidetector-row CT
    Teshima, Hideki
    Aoyagi, Shigeaki
    Ueda, Tomohiro
    Takagi, Kazuyoshi
    Shojima, Takahiro
    Tanaka, Hiroyuki
    JOURNAL OF ARTIFICIAL ORGANS, 2014, 17 (02) : 162 - 168
  • [42] Multidetector-row helical CT enteroclysisEnteroclisi-TC multistrato
    R. Di Mizio
    G. A. Rollandi
    M. Bellomi
    G. B. Meloni
    S. Cappabianca
    R. Grassi
    La radiologia medica, 2006, 111 : 1 - 10
  • [43] Intracranial haemorrhage studied by using multidetector-row CT angiography
    Saba, L.
    Mallarini, G.
    EUROPEAN JOURNAL OF NEUROLOGY, 2008, 15 : 264 - 264
  • [44] The value of multidetector-row CT in the preoperative detection of pancreatic insulinomas
    Liu, Y.
    Song, Q.
    Jin, H. T.
    Lin, X. Z.
    Chen, K. M.
    RADIOLOGIA MEDICA, 2009, 114 (08): : 1232 - 1238
  • [45] CT radiation dose parameters as applied to multidetector-row CT: CTDI and beyond
    Prasad, SR
    Tuli, R
    Wolsey, GT
    Chen, SR
    Dalrymple, NC
    Chintapalli, KN
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 87 - 87
  • [46] Three-dimensional volume rendering of multidetector-row CT data:: applicable for emergency radiology
    Philipp, MO
    Kubin, K
    Mang, T
    Hörmann, M
    Metz, VM
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (01) : 33 - 38
  • [47] T-staging of gastric cancer of air-filling multidetector-row CT: Comparison with hydro-multidetector-row CT
    Kumano, Seishi
    Okada, Masahiro
    Shimono, Taro
    Kuwabara, Masatomo
    Yagyu, Yukinobu
    Imaoka, Izumi
    Ashikaga, Ryuichiro
    Ishii, Kazunari
    Murakami, Takamichi
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 2953 - 2960
  • [48] Automatic segmentation of small pulmonary nodules on multidetector-row CT images
    Tachibana, R
    Kido, S
    Shouno, H
    Matsumoto, T
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1389 - 1389
  • [49] Multidetector-row CT evaluation of nontraumatic acute thoracic aortic syndromes
    Romano, L.
    Pinto, A.
    Gagliardi, N.
    RADIOLOGIA MEDICA, 2007, 112 (01): : 1 - 20
  • [50] Ex and in vivo coronary atherosclerotic plaque characterization with multidetector-row CT
    Becker, CR
    Nikolaou, K
    Muders, M
    Flohr, T
    Ohnesorge, B
    Reiser, MF
    CIRCULATION, 2002, 105 (14) : E108 - E108