Data explosion: the challenge of multidetector-row CT

被引:153
|
作者
Rubin, GD [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
multidetector-row CT; data explosion; 3D workstation;
D O I
10.1016/S0720-048X(00)00270-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-raw CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that same of these future developments might take are discussed. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 50 条
  • [31] Evaluation of advancing the standard valve dysfunction by multidetector-row CT
    Hideki Teshima
    Shigeaki Aoyagi
    Tomohiro Ueda
    Kazuyoshi Takagi
    Takahiro Shojima
    Hiroyuki Tanaka
    Journal of Artificial Organs, 2014, 17 : 162 - 168
  • [32] Acute lower gastrointestinal bleeding: multidetector-row CT findings
    Tsou, Kuei-Feng
    Chang, Wei-Chou
    Tsai, Shih-Hung
    Chang, Ching-Feng
    NEW ZEALAND MEDICAL JOURNAL, 2008, 121 (1272) : 94 - 96
  • [33] Multidetector-row CT angiography in the study of atherosclerotic carotid arteries
    Luca Saba
    Roberto Sanfilippo
    Raimondo Pirisi
    Luigi Pascalis
    Roberto Montisci
    Giorgio Mallarini
    Neuroradiology, 2007, 49 : 623 - 637
  • [34] Multidetector-row computed tomography
    El-Khoury, GY
    Bennett, DL
    Ondr, GJ
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (01) : 1 - 5
  • [35] Multidetector-row CT imaging of aneurysm rupture of the aortic arch
    Hoshino, Y
    Yamada, I
    Hayashi, S
    Machida, M
    Taya, T
    Ohki, I
    Takahashi, A
    Kurihara, T
    Arai, T
    Miyamoto, Y
    Togo, Y
    Hasegawa, A
    INTERNAL MEDICINE, 2004, 43 (07) : 634 - 636
  • [36] Multidetector-row CT: high performance but still many questions
    Blum, A
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 : S1 - S1
  • [37] Classification of lung area using multidetector-row CT images
    Mukaibo, T
    Kawata, Y
    Niki, N
    Ohmatsu, H
    Kakinuma, R
    Kaneko, M
    Eguchi, K
    Moriyama, N
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 1292 - 1300
  • [38] Misty mesentery: a pictorial review of multidetector-row CT findings
    Filippone, A.
    Cianci, R.
    Di Fabio, F.
    Storto, M. L.
    RADIOLOGIA MEDICA, 2011, 116 (03): : 351 - 365
  • [39] Multidetector-row helical CT: analysis of time management and workflow
    Roos, JE
    Desbiolles, LM
    Willmann, JK
    Weishaupt, D
    Marincek, B
    Hilfiker, PR
    EUROPEAN RADIOLOGY, 2002, 12 (03) : 680 - +
  • [40] Radiological emergency room management with emphasis on multidetector-row CT
    Philipp, MO
    Kubin, K
    Hörmann, M
    Metz, VM
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (01) : 2 - 4