In-vivo X-Ray micro-imaging and micro-CT with the Medipix2 semiconductor detector at UniAndes

被引:0
|
作者
Caicedo, I. [1 ]
Avila, C. [1 ]
Gomez, B. [1 ]
Bula, C. [1 ]
Roa, C. [1 ]
Sanabria, J. [1 ]
机构
[1] Univ Los Andes, Bogota, Colombia
关键词
Medipix; Pixel detectors; X-ray Imaging; In vivo X-ray micro-Imaging; Micro-CT;
D O I
10.1063/1.3688831
中图分类号
O59 [应用物理学];
学科分类号
摘要
This poster contains the procedure to obtain micro-CTs and to image moving samples using the Medipix2 detector, with its corresponding results. The high granularity of the detector makes it suitable for micro-CT. We used commercial software (Octopus) to do the 3D reconstruction of the samples in the first place, and we worked on modifying free reconstruction software afterwards. Medipix has a very fast response ( similar to hundreds of nanoseconds) and high sensibility. These features allow obtaining nearly in-vivo high resolution (55m * 55m) images. We used an exposure time of 0.1 s for each frame, and the resulting images were animated. The High Energy Physics Group at UniAndes is a member of the Medipix3 collaboration. Its research activities are focused on developing set-ups for biomedical applications and particle tracking using the Medipix2 and Timepix detectors, and assessing the feasibility of the Medipix3 detector for future applications.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Neutron imaging and tomography with Medipix2 and dental micro-roentgenography
    Jakubek, J.
    Granja, C.
    Holy, T.
    Lehmann, E.
    Linhart, V.
    Pospisil, S.
    Rypar, V.
    Uher, J.
    Vacik, J.
    Vavrik, D.
    Vykydal, Z.
    Cevallos, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 205 - 209
  • [42] Methods of in-vivo mouse lung micro-CT
    Recheis, W
    Nixon, E
    Thiesse, J
    McLennan, G
    Ross, A
    Hoffman, EA
    MEDICAL IMAGING 2005: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, PTS 1 AND 2, 2005, 5746 : 40 - 49
  • [43] High frame rate X-ray imaging with a 256 x 256 pixel single photon counting Medipix2 detector
    Mettivier, G.
    Montesi, M. C.
    Sebastiano, A.
    Russo, P.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1650 - 1655
  • [44] CAPILLARY OPTICS BASED X-RAY MICRO-IMAGING ELEMENTAL ANALYSIS
    Hampai, D.
    Dabagov, S. B.
    Cappuccio, G.
    Longoni, A.
    Frizzi, T.
    Cibin, G.
    CHARGED AND NEUTRAL PARTICLES CHANNELING PHENOMENA, CHANNELING 2008, 2010, 30 : 775 - 785
  • [45] Energy dispersive transmission X-ray scanning micro-imaging with an X-ray guide tube
    Hosokawa, Y
    Miyoshi, Y
    Tanabe, H
    Takarnatsu, T
    Obori, K
    Kawai, J
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) : 1301 - 1304
  • [46] X-ray and EUV micro-imaging systems for laser ICF diagnostics
    Yi Shengzhen
    Mu Baozhong
    Wang Xin
    Huang Wannian
    Jiang Li
    Wang Zhanshan
    11TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY (XRM2012), 2013, 463
  • [47] X-ray beam hardening based material recognition in micro-imaging
    Uher, J.
    Jakubek, J.
    Mayo, S.
    Stevenson, A.
    Tickner, J.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [48] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [49] Time-optimized X-ray micro-CT imaging of polymer based scaffolds
    Morris, David E.
    Mather, Melissa L.
    Simon, Carl G., Jr.
    Crowe, John A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (02) : 360 - 367
  • [50] Micro-CT X-ray imaging exposes structured diffusion barriers within biofilms
    Alona Keren-Paz
    Vlad Brumfeld
    Yaara Oppenheimer-Shaanan
    Ilana Kolodkin-Gal
    npj Biofilms and Microbiomes, 4