In-vivo X-Ray micro-imaging and micro-CT with the Medipix2 semiconductor detector at UniAndes

被引:0
|
作者
Caicedo, I. [1 ]
Avila, C. [1 ]
Gomez, B. [1 ]
Bula, C. [1 ]
Roa, C. [1 ]
Sanabria, J. [1 ]
机构
[1] Univ Los Andes, Bogota, Colombia
关键词
Medipix; Pixel detectors; X-ray Imaging; In vivo X-ray micro-Imaging; Micro-CT;
D O I
10.1063/1.3688831
中图分类号
O59 [应用物理学];
学科分类号
摘要
This poster contains the procedure to obtain micro-CTs and to image moving samples using the Medipix2 detector, with its corresponding results. The high granularity of the detector makes it suitable for micro-CT. We used commercial software (Octopus) to do the 3D reconstruction of the samples in the first place, and we worked on modifying free reconstruction software afterwards. Medipix has a very fast response ( similar to hundreds of nanoseconds) and high sensibility. These features allow obtaining nearly in-vivo high resolution (55m * 55m) images. We used an exposure time of 0.1 s for each frame, and the resulting images were animated. The High Energy Physics Group at UniAndes is a member of the Medipix3 collaboration. Its research activities are focused on developing set-ups for biomedical applications and particle tracking using the Medipix2 and Timepix detectors, and assessing the feasibility of the Medipix3 detector for future applications.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Effect of experimental parameters on X-ray Micro-CT imaging for Spectral CT applications
    Lima, Mateus Gruener
    Jussiani, Eduardo Inocente
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [32] A portable acquisition system based on USB standardfor the Medipix2 X-ray detector
    Fanti, V
    Marzeddu, R
    Piredda, G
    Randaccio, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3226 - 3228
  • [33] Reconstruction of X-ray spectra with the energy sensitive photon counting detector Medipix2
    Michel, Thilo
    Talla, Patrick Takoukam
    Firsching, Markus
    Durst, Juergen
    Boehnel, Michael
    Anton, Gisela
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (02): : 510 - 514
  • [34] Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation
    Uher, J.
    Jakubek, J.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [35] An experimental micro-CT system for X-ray NDT
    Rossi, M
    Casali, F
    Bettuzzi, M
    Morigi, MP
    Romani, A
    Golovkin, SV
    Govorun, VN
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 338 - 348
  • [36] Small Animal X-ray Micro-CT with Zoom-in Imaging Capability
    Lee, Soo Yeol
    Cho, Min Hyoung
    Lee, Sang Chul
    Chun, In Kon
    Park, Jeong Jin
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3102 - 3105
  • [37] A portable acquisition system based on USB standard for the Medipix2 X-Ray detector
    Fanti, V.
    Marzeddu, R.
    Piredda, G.
    Randaccio, R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2578 - 2583
  • [38] X-ray strain tensor imaging: FEM simulation and experiments with a micro-CT
    Kim, Jae G.
    Park, So E.
    Lee, Soo Y.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 63 - 75
  • [39] A perfusion procedure for imaging of the mouse cerebral vasculature by X-ray micro-CT
    Ghanavati, Sahar
    Yu, Lisa X.
    Lerch, Jason P.
    Sled, John G.
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 221 : 70 - 77
  • [40] Optical link based readout system for Medipix2 quad X-ray detector
    Fanti, V.
    Marzeddu, R.
    Randaccio, P.
    Aloisio, A.
    Del Guerra, A.
    Lanconelli, N.
    Mettivier, G.
    Montesi, M. C.
    Pani, R.
    Russo, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 137 - 141