A first step toward a new national standard for direct calibrations in clinical high energy photon beams

被引:0
|
作者
Chen-Mayer, H
Tosh, R
Bateman, F
Speicher, P
机构
[1] NIST, Gaithersburg, MD 20899 USA
[2] Univ Virginia, Charlottesville, VA USA
关键词
D O I
10.1118/1.1998522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Clinical reference dosimetry for high‐energy photon and electron beams is based on ion‐chamber calibrations in a Co‐60 beam for absorbed dose to water, as prescribed in the TG‐51 protocol. A complex formalism is required when converting the calibration to the beam quality of end users. Direct calibrations in clinical high‐energy x‐ray beams will eliminate the complexity and associated uncertainties, resulting in greater accuracy and measurement simplicity. Method and Materials: The current primary standard for absorbed dose is transferred through ionization chamber measurements in a Co‐60 beam and is ultimately traceable to the first‐generation water calorimeter developed at NIST by Domen. We are evaluating a new calorimeter with modern data acquisition in a Clinac 2100C photon beam at 6 MV and 18 MV. Results: To address the convection/conduction problems inherent to water calorimetry, we have devised a novel data‐collection scheme with multiple cycles of radiation‐induced temperature increase as a function of time; this has greatly improved the efficiency of measurements, thereby achieving greater precision. The temperature rise can be extracted by three approaches that yield consistent results; these will be described in detail in the presentation. The absorbed dose determined at 18 MV and 6 MV using the water calorimeter at selected depth along the beam axis are compared to the depth‐dose curves measured with a calibrated ion chamber following the TG‐51 protocol. In addition, the dependence of bridge‐excitation voltage at the higher dose rate (4 Gy/min) behaves differently from that at a lower rate (1 Gy/min) in a Co‐60 beam; this has been investigated in order to assess the influence of the thermistor power on measured results. Conclusion: We have obtained preliminary results and are moving toward a new national standard for direct calibrations in clinical beams. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2127 / 2128
页数:2
相关论文
共 50 条
  • [41] New external beam and particle detection set-up of Liege cyclotron - First applications of high energy beams to cultural heritage
    Chene, G.
    Bols, S.
    Dupuis, T.
    Marchal, A.
    Mathis, F.
    Garnir, H. -P.
    Strivay, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 273 : 208 - 212
  • [42] First direct 7Be electron-capture Q-value measurement toward high-precision searches for neutrino physics beyond the Standard Model
    Bhandari, R.
    Bollen, G.
    Brunner, T.
    Gamage, N. D.
    Hamaker, A.
    Hockenbery, Z.
    Gamage, M. Horana
    Keblbeck, D. K.
    Leach, K. G.
    Puentes, D.
    Redshaw, M.
    Ringle, R.
    Schwarz, S.
    Sumithrarachchi, C. S.
    Yandow, I.
    PHYSICAL REVIEW C, 2024, 109 (02)
  • [44] Response to "Comment on 'Attenuation characteristics of a new compensator material: Thermo-Shield for high energy electron and photon beams'" [Med. Phys. 25, 1760 (1998)]
    Das, RK
    Paliwal, BR
    MEDICAL PHYSICS, 1998, 25 (09) : 1761 - 1761
  • [45] Comment on "Attenuation characteristics of a new compensator material: Thermo-Shield for high energy electron and photon beams" [Med. Phys. 25, 485-487 (1998)]
    Murray, B
    Mihailidis, D
    MEDICAL PHYSICS, 1998, 25 (09) : 1760 - 1760
  • [46] Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments
    Paelinck, L
    De Wagter, C
    Van Esch, A
    Duthoy, W
    Depuydt, T
    De Neve, W
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (03): : 413 - 428
  • [47] Comment on "AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams" [Med. Phys. 26, 1847-1870 (1999)]
    Khan, FM
    MEDICAL PHYSICS, 2000, 27 (03) : 445 - 447
  • [48] X-ray production cross-sections measurements for high-energy alpha particle beams: New dedicated set-up and first results with aluminum
    Dupuis, T.
    Chene, G.
    Mathis, F.
    Marchal, A.
    Garnir, H. -P.
    Strivay, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (24): : 2979 - 2983
  • [49] First clinical experience with the new four-pole standard connector for high-voltage ICD leads. Early results of a multicenter comparison with conventional implant outcomes
    Giovanni B. Forleo
    Luigi Di Biase
    Massimo Mantica
    Germana Panattoni
    Matteo Santamaria
    Quintino Parisi
    Domenico Sergi
    Lida P. Papavasileiou
    Luca Santini
    Claudio Tondo
    Andrea Natale
    Francesco Romeo
    Journal of Interventional Cardiac Electrophysiology, 2013, 38 : 11 - 18
  • [50] First clinical experience with the new four-pole standard connector for high-voltage ICD leads. Early results of a multicenter comparison with conventional implant outcomes
    Forleo, Giovanni B.
    Di Biase, Luigi
    Mantica, Massimo
    Panattoni, Germana
    Santamaria, Matteo
    Parisi, Quintino
    Sergi, Domenico
    Papavasileiou, Lida P.
    Santini, Luca
    Tondo, Claudio
    Natale, Andrea
    Romeo, Francesco
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2013, 38 (01) : 11 - 18