A first step toward a new national standard for direct calibrations in clinical high energy photon beams

被引:0
|
作者
Chen-Mayer, H
Tosh, R
Bateman, F
Speicher, P
机构
[1] NIST, Gaithersburg, MD 20899 USA
[2] Univ Virginia, Charlottesville, VA USA
关键词
D O I
10.1118/1.1998522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Clinical reference dosimetry for high‐energy photon and electron beams is based on ion‐chamber calibrations in a Co‐60 beam for absorbed dose to water, as prescribed in the TG‐51 protocol. A complex formalism is required when converting the calibration to the beam quality of end users. Direct calibrations in clinical high‐energy x‐ray beams will eliminate the complexity and associated uncertainties, resulting in greater accuracy and measurement simplicity. Method and Materials: The current primary standard for absorbed dose is transferred through ionization chamber measurements in a Co‐60 beam and is ultimately traceable to the first‐generation water calorimeter developed at NIST by Domen. We are evaluating a new calorimeter with modern data acquisition in a Clinac 2100C photon beam at 6 MV and 18 MV. Results: To address the convection/conduction problems inherent to water calorimetry, we have devised a novel data‐collection scheme with multiple cycles of radiation‐induced temperature increase as a function of time; this has greatly improved the efficiency of measurements, thereby achieving greater precision. The temperature rise can be extracted by three approaches that yield consistent results; these will be described in detail in the presentation. The absorbed dose determined at 18 MV and 6 MV using the water calorimeter at selected depth along the beam axis are compared to the depth‐dose curves measured with a calibrated ion chamber following the TG‐51 protocol. In addition, the dependence of bridge‐excitation voltage at the higher dose rate (4 Gy/min) behaves differently from that at a lower rate (1 Gy/min) in a Co‐60 beam; this has been investigated in order to assess the influence of the thermistor power on measured results. Conclusion: We have obtained preliminary results and are moving toward a new national standard for direct calibrations in clinical beams. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2127 / 2128
页数:2
相关论文
共 50 条
  • [31] Development of a Quasi-Adiabatic Miniature Graphite Calorimeter for Absolute Clinical Dosimetry of High-Energy Photon Beams
    Keszti, F.
    Cote, B.
    Bancheri, J.
    Sarfehnia, A.
    Seuntjens, J.
    Renaud, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E287 - E287
  • [32] Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams
    McEwen, Malcolm
    DeWerd, Larry
    Ibbott, Geoffrey
    Followill, David
    Rogers, David W. O.
    Seltzer, Stephen
    Seuntjens, Jan
    MEDICAL PHYSICS, 2014, 41 (04)
  • [34] Dosimetric performance of the new PTW 31022 PinPoint 3D ionization chamber in high energy photon beams
    Vieillevigne, Laure
    Arnaud, Francois Xavier
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (04):
  • [35] Design and characterization of a tissue-equivalent CVD-diamond detector for clinical dosimetry in high-energy photon beams
    Gorka, B.
    Nilsson, B.
    Svensson, R.
    Brahme, A.
    Ascarelli, P.
    Trucchi, D. M.
    Conte, G.
    Kalish, R.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2008, 24 (03): : 159 - 168
  • [36] Comment on clinical implementation of the AAPM's Task Group-51 protocol for calibration of high-energy photon and electron beams
    Rodgers, JE
    Niroomand-Rad, A
    Lundsten, M
    MEDICAL PHYSICS, 2000, 27 (08) : 1995 - 1996
  • [37] Knowledge-based data analysis: First step toward the creation of clinical prediction rules using a new typicality measure
    Kwiatkowska, Mila
    Atkins, M. Stella
    Ayas, Najib T.
    Ryan, C. Frank
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2007, 11 (06): : 651 - 660
  • [38] Assessing peak inspiratory flow for initial high flow nasal cannula setting: the end point or a first step toward a new approach?
    Papoff, Paola
    Montecchia, Francesco
    JOURNAL OF PEDIATRICS, 2021, 234 : 289 - 289
  • [39] Reference dosimetry in clinical high-energy photon beams: Comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols
    Huq, MS
    Andreo, P
    MEDICAL PHYSICS, 2001, 28 (01) : 46 - 54
  • [40] Assessing peak inspiratory flow for initial high flow nasal cannula setting: the end point or a first step toward a new approach? Reply
    Milesi, Christophe
    Baleine, Julien
    Cambonie, Gilles
    JOURNAL OF PEDIATRICS, 2021, 234 : 289 - 290