A first step toward a new national standard for direct calibrations in clinical high energy photon beams

被引:0
|
作者
Chen-Mayer, H
Tosh, R
Bateman, F
Speicher, P
机构
[1] NIST, Gaithersburg, MD 20899 USA
[2] Univ Virginia, Charlottesville, VA USA
关键词
D O I
10.1118/1.1998522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Clinical reference dosimetry for high‐energy photon and electron beams is based on ion‐chamber calibrations in a Co‐60 beam for absorbed dose to water, as prescribed in the TG‐51 protocol. A complex formalism is required when converting the calibration to the beam quality of end users. Direct calibrations in clinical high‐energy x‐ray beams will eliminate the complexity and associated uncertainties, resulting in greater accuracy and measurement simplicity. Method and Materials: The current primary standard for absorbed dose is transferred through ionization chamber measurements in a Co‐60 beam and is ultimately traceable to the first‐generation water calorimeter developed at NIST by Domen. We are evaluating a new calorimeter with modern data acquisition in a Clinac 2100C photon beam at 6 MV and 18 MV. Results: To address the convection/conduction problems inherent to water calorimetry, we have devised a novel data‐collection scheme with multiple cycles of radiation‐induced temperature increase as a function of time; this has greatly improved the efficiency of measurements, thereby achieving greater precision. The temperature rise can be extracted by three approaches that yield consistent results; these will be described in detail in the presentation. The absorbed dose determined at 18 MV and 6 MV using the water calorimeter at selected depth along the beam axis are compared to the depth‐dose curves measured with a calibrated ion chamber following the TG‐51 protocol. In addition, the dependence of bridge‐excitation voltage at the higher dose rate (4 Gy/min) behaves differently from that at a lower rate (1 Gy/min) in a Co‐60 beam; this has been investigated in order to assess the influence of the thermistor power on measured results. Conclusion: We have obtained preliminary results and are moving toward a new national standard for direct calibrations in clinical beams. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2127 / 2128
页数:2
相关论文
共 50 条
  • [1] ABSORBED-DOSE CALIBRATIONS IN HIGH-ENERGY PHOTON BEAMS AT THE NATIONAL-PHYSICAL-LABORATORY - CONVERSION PROCEDURE
    BURNS, JE
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10): : 1555 - 1575
  • [2] Electron contamination in clinical high energy photon beams
    Sjogren, R
    Karlsson, M
    MEDICAL PHYSICS, 1996, 23 (11) : 1873 - 1881
  • [3] First direct comparison of measured kQ values for FFF and FF clinical photon beams
    De Prez, L. A.
    Jansen, B. J.
    De Pooter, J. A.
    Perik, T. J.
    Wittkamper, F. W.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S268 - S269
  • [4] Photoacoustic dose monitoring in clinical high-energy photon beams
    Giza, Olivia M.
    Sanchez-Parcerisa, Daniel
    Sanchez-Tembleque, Victor
    Herraiz, Joaquin L.
    Camacho, Jorge
    Avery, Stephen
    Manuel Udias, Jose
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):
  • [5] OUTPUT CALIBRATIONS OF HIGH-ENERGY PHOTON AND ELECTRON-BEAMS USING VARIOUS IONIZATION CHAMBERS IN DIFFERENT MATERIALS
    REFT, CS
    MULLERRUNKLE, R
    MEDICAL PHYSICS, 1986, 13 (04) : 606 - 606
  • [6] Analysis of Uncertainties in Clinical High-Energy Photon Beam Calibrations Using Absorbed Dose Standards
    Elbashir, Fawzia E. M.
    Ksouri, Wassim
    Habbani, Farouk
    El-Khayatt, Ahmed M.
    Eisa, Mohamed Hassan
    Suliman, Ibrahim I.
    APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [7] New KQ Factors for Reference Dosimetry in High-Energy Photon Beams
    McEwen, M.
    Rogers, D.
    MEDICAL PHYSICS, 2008, 35 (06) : 2994 - +
  • [8] NEW PROTOCOLS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON AND ELECTRON-BEAMS
    DUTREIX, A
    MIJNHEER, B
    SVENSSON, H
    RADIOTHERAPY AND ONCOLOGY, 1985, 4 (04) : 289 - 290
  • [9] A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering
    Burch, SE
    Kearfott, KJ
    Trueblood, JH
    Sheils, WC
    Yeo, JI
    Wang, CKC
    MEDICAL PHYSICS, 1997, 24 (05) : 775 - 783
  • [10] Dosimetric Properties of a New Solid Water High Equivalency Phantom for High-Energy Photon Beams
    Araki, F.
    Ohno, T.
    Onitsuka, R.
    Shimohigashi, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3410 - 3410