Amperometric Determination of Glucose in White Grape and in Tablets as Ingredient by Screen-Printed Electrode Modified with Glucose Oxidase and Composite of Platinum and Multiwalled Carbon Nanotubes

被引:11
|
作者
Guzsvany, Valeria [1 ]
Anojcic, Jasmina [1 ]
Vajdle, Olga [1 ]
Radulovic, Emil [1 ]
Madarasz, Daniel [2 ]
Konya, Zoltan [2 ,3 ]
Kalcher, Kurt [4 ]
机构
[1] Univ Novi Sad, Dept Chem Biochem & Environm Protect, Fac Sci, Trg D Obradovica 3, Novi Sad 21000, Serbia
[2] Univ Szeged, Dept Appl & Environm Chem, Rerrich Bela Ter 1, H-6720 Szeged, Hungary
[3] MTA SZTE React Kinet & Surface Chem Res Grp, Rerrich Bela Ter 1, H-6720 Szeged, Hungary
[4] Karl Franzens Univ Graz, Inst Chem Analyt Chem, Univ Pl 1, A-8010 Graz, Austria
关键词
Screen-printed carbon electrode; Platinum and multiwalled carbon nanotube composite mediator; Glucose oxidase; Amperometry; Glucose determination; Food samples; ELECTROCHEMICAL SENSORS; BIOSENSORS; NANOPARTICLES; FOOD;
D O I
10.1007/s12161-018-1387-7
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Multiwalled carbon nanotubes (MWCNTs) and nanocomposite made from MWCNTs and Pt nanoparticles (Pt-MWCNTs) were used as bulk modifiers of screen-printed carbon electrodes (SPCEs). Cyclic voltammetric and amperometric measurements were performed by the homemade substrate electrodes, the bare SPCE and the modified ones (MWCNT-SPCE and Pt-MWCNT-SPCE), with aim to investigate their applicability for determination of H2O2 in phosphate buffer solution (0.1M; pH7.50) as supporting electrolyte. Pt-MWCNT-SPCE showed improved analytical performances including the significant decrease in overpotential of H2O2 compared to SPCE and MWCNT-SPCE. So, Pt-MWCNT-SPCE served as substrate electrode for design of a simple first-generation biosensor made from glucose oxidase (GOx) and Nafion((R)) forming the GOx/Pt-MWCNT-SPCE for reliable determination of glucose via its enzymatic by-product, the H2O2. The surface morphology characterization by scanning electron microscopy confirmed the presence of immobilized spherical shaped biosensing units at the GOx/Pt-MWCNT-SPCE. In the case of amperometry of glucose, optimal potential for the working electrode was -0.50V vs. SCE, and a satisfactory linearity was obtained in the tested concentration range from 65.8 to 260.6gmL(-1), with estimated LOQ of 35.0gmL(-1). The developed cost-effective amperometric method in combination with GOx/Pt-MWCNT-SPCE was successfully applied for the determination of glucose in selected food samples: white grapes and glucose tablets. The obtained results were in good agreement with those received by the alternatively used commercially available glucometer and by the producer declared value in the case of the tablet sample as well.
引用
收藏
页码:570 / 580
页数:11
相关论文
共 50 条
  • [31] Sequential Injection Amperometric Determination of Glucose in Saliva Using a Screen-Printed Electrode Modified with a Gold-Cobalt Binary System
    Shaidarova, L. G.
    Chelnokova, I. A.
    Gafiatova, I. A.
    Gedmina, A. V.
    Budnikov, H. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (03) : 372 - 377
  • [32] Electrochemical Determination of Catechol Using Functionalized Multiwalled Carbon Nanotubes modified Screen Printed Carbon Electrode
    Rao, Mettu Mallikarjuna
    Settu, Ramki
    Chen, Shen-Ming
    Alagarsamy, Periyalagan
    Chen, Tse-Wei
    Hong, In-Seok
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (06): : 6126 - 6134
  • [33] Glucose biosensor based on screen-printed electrode modified with silicone sol–gel conducting matrix containing carbon nanotubes
    O. A. Kamanina
    S. S. Kamanin
    A. S. Kharkova
    V. A. Arlyapov
    3 Biotech, 2019, 9
  • [34] Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode
    Amatatongchai, Maliwan
    Sroysee, Wongduan
    Chairam, Sanoe
    Nacapricha, Duangjai
    TALANTA, 2017, 166 : 420 - 427
  • [35] Glucose biosensors based on a gold nanodendrite modified screen-printed electrode
    Liu, Hsi-Chien
    Tsai, Chung-Che
    Wang, Gou-Jen
    NANOTECHNOLOGY, 2013, 24 (21)
  • [36] Amperometric glucose biosensor. Electrode modified with carbon nanotubes
    Gutierrez, Alejandro
    Rodriguez, Marcela C.
    Galicia, Laura
    Rivas, Gustavo A.
    MES 26: ELECTROCHEMISTRY AS A TOOL FOR SUSTAINABLE DEVELOPMENT, 2011, 36 (01): : 393 - 400
  • [37] Amperometric fructose sensor based on ferrocyanide modified screen-printed carbon electrode
    Biscay, Julien
    Costa Rama, Estefania
    Gonzalez Garcia, Maria Begona
    Julio Reviejo, A.
    Pingarron Carrazon, Jose Manuel
    Costa Garcia, Agustin
    TALANTA, 2012, 88 : 432 - 438
  • [38] A paper disk equipped with graphene/polyaniline/Au nanoparticles/glucose oxidase biocomposite modified screen-printed electrode: Toward whole blood glucose determination
    Kong, Fen-Ying
    Gu, Sai-Xi
    Li, Wei-Wei
    Chen, Ting-Ting
    Xu, Qin
    Wang, Wei
    BIOSENSORS & BIOELECTRONICS, 2014, 56 : 77 - 82
  • [39] Capabilities of amperometric monoamine oxidase biosensors based on screen-printed graphite electrodes modified with multiwall carbon nanotubes in the determination of some antidepressants
    Medyantseva, E. P.
    Brusnitsyn, D. V.
    Varlamova, R. M.
    Beshevets, M. A.
    Budnikov, H. C.
    Fattakhova, A. N.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (05) : 535 - 539
  • [40] Simultaneous determination of maltose and glucose using a screen-printed electrode system
    Ge, F
    Zhang, XE
    Zhang, ZP
    Zhang, XM
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4): : 333 - 339