Amperometric Determination of Glucose in White Grape and in Tablets as Ingredient by Screen-Printed Electrode Modified with Glucose Oxidase and Composite of Platinum and Multiwalled Carbon Nanotubes

被引:11
|
作者
Guzsvany, Valeria [1 ]
Anojcic, Jasmina [1 ]
Vajdle, Olga [1 ]
Radulovic, Emil [1 ]
Madarasz, Daniel [2 ]
Konya, Zoltan [2 ,3 ]
Kalcher, Kurt [4 ]
机构
[1] Univ Novi Sad, Dept Chem Biochem & Environm Protect, Fac Sci, Trg D Obradovica 3, Novi Sad 21000, Serbia
[2] Univ Szeged, Dept Appl & Environm Chem, Rerrich Bela Ter 1, H-6720 Szeged, Hungary
[3] MTA SZTE React Kinet & Surface Chem Res Grp, Rerrich Bela Ter 1, H-6720 Szeged, Hungary
[4] Karl Franzens Univ Graz, Inst Chem Analyt Chem, Univ Pl 1, A-8010 Graz, Austria
关键词
Screen-printed carbon electrode; Platinum and multiwalled carbon nanotube composite mediator; Glucose oxidase; Amperometry; Glucose determination; Food samples; ELECTROCHEMICAL SENSORS; BIOSENSORS; NANOPARTICLES; FOOD;
D O I
10.1007/s12161-018-1387-7
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Multiwalled carbon nanotubes (MWCNTs) and nanocomposite made from MWCNTs and Pt nanoparticles (Pt-MWCNTs) were used as bulk modifiers of screen-printed carbon electrodes (SPCEs). Cyclic voltammetric and amperometric measurements were performed by the homemade substrate electrodes, the bare SPCE and the modified ones (MWCNT-SPCE and Pt-MWCNT-SPCE), with aim to investigate their applicability for determination of H2O2 in phosphate buffer solution (0.1M; pH7.50) as supporting electrolyte. Pt-MWCNT-SPCE showed improved analytical performances including the significant decrease in overpotential of H2O2 compared to SPCE and MWCNT-SPCE. So, Pt-MWCNT-SPCE served as substrate electrode for design of a simple first-generation biosensor made from glucose oxidase (GOx) and Nafion((R)) forming the GOx/Pt-MWCNT-SPCE for reliable determination of glucose via its enzymatic by-product, the H2O2. The surface morphology characterization by scanning electron microscopy confirmed the presence of immobilized spherical shaped biosensing units at the GOx/Pt-MWCNT-SPCE. In the case of amperometry of glucose, optimal potential for the working electrode was -0.50V vs. SCE, and a satisfactory linearity was obtained in the tested concentration range from 65.8 to 260.6gmL(-1), with estimated LOQ of 35.0gmL(-1). The developed cost-effective amperometric method in combination with GOx/Pt-MWCNT-SPCE was successfully applied for the determination of glucose in selected food samples: white grapes and glucose tablets. The obtained results were in good agreement with those received by the alternatively used commercially available glucometer and by the producer declared value in the case of the tablet sample as well.
引用
收藏
页码:570 / 580
页数:11
相关论文
共 50 条
  • [21] Sequential Injection Amperometric Determination of Glucose in Saliva Using a Screen-Printed Electrode Modified with a Gold–Cobalt Binary System
    L. G. Shaidarova
    I. A. Chelnokova
    I. A. Gafiatova
    A. V. Gedmina
    H. C. Budnikov
    Journal of Analytical Chemistry, 2023, 78 : 372 - 377
  • [22] Simultaneous determination of dihydroxybenzene isomers using disposable screen-printed electrode modified by multiwalled carbon nanotubes and gold nanoparticles
    Li, Da-Wei
    Li, Yuan-Ting
    Song, Wei
    Long, Yi-Tao
    ANALYTICAL METHODS, 2010, 2 (07) : 837 - 843
  • [23] Development of single-wall carbon nanotubes modified screen-printed electrode using a ferrocene-modified cationic surfactant for amperometric glucose biosensor applications
    Sato, Naruhide
    Okuma, Hirokazu
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01) : 188 - 194
  • [24] An amperometric glucose biosensor constructed by immobilizing glucose oxidase on titanium-containing mesoporous composite material of no. 41 modified screen-printed electrodes
    Dai, Zhihui
    Fang, Min
    Bao, Jianchun
    Wang, Huaisheng
    Lu, Tianhong
    ANALYTICA CHIMICA ACTA, 2007, 591 (02) : 195 - 199
  • [25] Amperometric glucose sensor based on glucose oxidase immobilized on gelatin-multiwalled carbon nanotube modified glassy carbon electrode
    Periasamy, Arun Prakash
    Chang, Yu-Jung
    Chen, Shen-Ming
    BIOELECTROCHEMISTRY, 2011, 80 (02) : 114 - 120
  • [26] Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode
    Tang, H
    Chen, JH
    Yao, SZ
    Nie, LH
    Deng, GH
    Kuang, YF
    ANALYTICAL BIOCHEMISTRY, 2004, 331 (01) : 89 - 97
  • [27] Carbon Nanostructured Screen-printed Electrodes Modified with CuO/Glucose Oxidase/Maltase/SiO2Composite Film for Maltose Determination
    Kornii, Anastasiia
    Saska, Vita
    Lisnyak, Vladyslav V.
    Tananaiko, Oksana
    ELECTROANALYSIS, 2020, 32 (07) : 1468 - 1479
  • [28] An electrochemically preanodized screen-printed carbon electrode for achieving direct electron transfer to glucose oxidase
    Yang, Ting-Hao
    Hung, Chi-Lung
    Ke, Jyh-Harng
    Zen, Jyh-Myng
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (07) : 1094 - 1097
  • [29] Activity enhancement of a screen-printed carbon electrode by modification with gold nanoparticles for glucose determination
    Masaru Iwamoto
    Shiho Tokonami
    Hiroshi Shiigi
    Tsutomu Nagaoka
    Research on Chemical Intermediates, 2009, 35
  • [30] Activity enhancement of a screen-printed carbon electrode by modification with gold nanoparticles for glucose determination
    Iwamoto, Masaru
    Tokonami, Shiho
    Shiigi, Hiroshi
    Nagaoka, Tsutomu
    RESEARCH ON CHEMICAL INTERMEDIATES, 2009, 35 (8-9) : 919 - 930