Enhanced Biosensing Activity of Bimetallic Surface Plasmon Resonance Sensor

被引:32
|
作者
Kashyap, Ritayan [1 ]
Chakraborty, Soumik [1 ]
Zeng, Shuwen [2 ]
Swarnakar, Sikha [1 ]
Kaur, Simran [3 ]
Doley, Robin [3 ]
Mondal, Biplob [1 ]
机构
[1] Tezpur Univ, Dept Elect & Commun Engn, Tezpur 784028, Assam, India
[2] Univ Limoges, CNRS, XLIM Res Inst, UMR 7252, 123 Ave Albert Thomas, F-87060 Limoges, France
[3] Tezpur Univ, Dept Mol Biol & Biotechnol, Tezpur 784028, Assam, India
基金
欧盟地平线“2020”;
关键词
full width at half maximum (FWHM); monoclonal anti-IgG; pulsed DC magnetron; sensitivity; surface plasmon resonance; IMMOBILIZATION STRATEGIES; ANTIBODY INTERACTION; GOLD NANOPARTICLES; FIELD ENHANCEMENT; GAS-DETECTION; SENSITIVITY; SILVER; FILM;
D O I
10.3390/photonics6040108
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Surface plasmon resonance (SPR) sensors present a challenge when high sensitivity and small FWHM (full width at half maximum) are required to be achieved simultaneously. FWHM is defined by the difference between the two extreme values of the independent variable at which the value of the dependent variable is equal to half of its maximum. A smaller value of FWHM indicates better accuracy of SPR measurements. Theoretically, many authors have claimed the possibility of simultaneously achieving high sensitivity and small FWHM, which in most of the cases has been limited by experimental validation. In this report, an experimental study on the improved surface plasmon resonance (SPR) characteristics of gold over silver bimetallic sensor chips of different film thicknesses is presented. A comparative study of antigen-antibody interaction of the bimetallic chip using a custom-made, low-cost, and portable SPR device based on an angular interrogation scheme of Kretschmann configuration is performed. Pulsed direct current (DC) magnetron-sputtered bimetallic films of gold over silver were used in the construction of the SPR chip. The FWHM and sensitivity of the bimetallic sensors were firstly characterized using standard solutions of known refractive index which were later immobilized with monoclonal anti-immunoglobulin G (IgG) in the construction of the SPR biochip. Spectroscopic measurements such as ultraviolet-visible light spectroscopy (UV-Vis) and Fourier-transform infrared spectroscopy (FTIR) were used for the confirmation of the immobilization of the antibody. The performance of the bimetallic SPR biochip was investigated by exposing the sensor to various concentrations of the target protein. The results indicated that the bimetallic sensors of silver/gold had a 3.5-fold reduced FWHM compared to pure gold-based sensors, indicating a higher detection accuracy. In addition, they exhibited a significant shift in resonance angle as high as 8.5 +/- 0.2 due to antigen-antibody interaction, which was similar to 1.42-fold higher than observed for pure silver-based sensors.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Surface plasmon resonance sensor
    Han, Won-Sik
    Jung, Kyu-jin
    Lee, Sang-Won
    Hong, Suk-Young
    Lee, Young-Hoon
    Hong, Tae-Kee
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (01): : 9 - 17
  • [32] Bimetallic chips for a surface plasmon resonance instrument
    Chen, Y.
    Zheng, R. S.
    Zhang, D. G.
    Lu, Y. H.
    Wang, P.
    Ming, H.
    Luo, Z. F.
    Kan, Q.
    APPLIED OPTICS, 2011, 50 (03) : 387 - 391
  • [33] Enhancement in figure of merit of silver-gold bimetallic surface plasmon resonance sensor
    Huang, Yan
    Li, Peiyan
    Wang, Chengxiang
    Yao, Zheli
    Lyu, Guohui
    Li, Hongwei
    OPTICS FRONTIERS ONLINE 2020: MICRO AND NANOPHOTONICS (OFO-4 2020), 2020, 11608
  • [34] Resonance Effect of Bimetallic Diffraction Grating on the Sensing Characteristics of Surface Plasmon Resonance Sensor with COMSOL Multiphysics
    Singh, Sarbjit
    Kaler, R. S.
    Sharma, Siddharth
    JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2019, 14 (05) : 669 - 674
  • [35] Optical biosensing using surface plasmon resonance spectroscopy
    Homola, J
    Pfeifer, P
    Brynda, E
    Skvor, J
    Houska, M
    Schwotzer, G
    Latka, I
    Willsch, R
    CHEMICAL, BIOCHEMICAL, AND ENVIRONMENTAL FIBER SENSORS IX, 1997, 3105 : 318 - 324
  • [36] Surface plasmon resonance for biosensing: A mini-review
    Abdulhalim, Ibrahim
    Zourob, Mohammad
    Lakhtakia, Akhlesh
    ELECTROMAGNETICS, 2008, 28 (03) : 214 - 242
  • [37] Layered material platform for surface plasmon resonance biosensing
    Wu, F.
    Thomas, P. A.
    Kravets, V. G.
    Arola, H. O.
    Soikkeli, M.
    Iljin, K.
    Kim, G.
    Kim, M.
    Shin, H. S.
    Andreeva, D., V
    Neumann, C.
    Kuellmer, M.
    Turchanin, A.
    De Fazio, D.
    Balci, O.
    Babenko, V
    Luo, B.
    Goykhman, I
    Hofmann, S.
    Ferrari, A. C.
    Novoselov, K. S.
    Grigorenko, A. N.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [38] Layered material platform for surface plasmon resonance biosensing
    F. Wu
    P. A. Thomas
    V. G. Kravets
    H. O. Arola
    M. Soikkeli
    K. Iljin
    G. Kim
    M. Kim
    H. S. Shin
    D. V. Andreeva
    C. Neumann
    M. Küllmer
    A. Turchanin
    D. De Fazio
    O. Balci
    V. Babenko
    B. Luo
    I. Goykhman
    S. Hofmann
    A. C. Ferrari
    K. S. Novoselov
    A. N. Grigorenko
    Scientific Reports, 9
  • [39] Advances in localized surface plasmon resonance spectroscopy biosensing
    Sagle, Laura B.
    Ruvuna, Laura K.
    Ruemmele, Julia A.
    Van Duyne, Richard P.
    NANOMEDICINE, 2011, 6 (08) : 1447 - 1462
  • [40] 30 Years of Surface Plasmon Resonance (SPR) for Biosensing
    Geddes, Chris D.
    PLASMONICS, 2014, 9 (04) : 727 - 727