Enhanced Biosensing Activity of Bimetallic Surface Plasmon Resonance Sensor

被引:32
|
作者
Kashyap, Ritayan [1 ]
Chakraborty, Soumik [1 ]
Zeng, Shuwen [2 ]
Swarnakar, Sikha [1 ]
Kaur, Simran [3 ]
Doley, Robin [3 ]
Mondal, Biplob [1 ]
机构
[1] Tezpur Univ, Dept Elect & Commun Engn, Tezpur 784028, Assam, India
[2] Univ Limoges, CNRS, XLIM Res Inst, UMR 7252, 123 Ave Albert Thomas, F-87060 Limoges, France
[3] Tezpur Univ, Dept Mol Biol & Biotechnol, Tezpur 784028, Assam, India
基金
欧盟地平线“2020”;
关键词
full width at half maximum (FWHM); monoclonal anti-IgG; pulsed DC magnetron; sensitivity; surface plasmon resonance; IMMOBILIZATION STRATEGIES; ANTIBODY INTERACTION; GOLD NANOPARTICLES; FIELD ENHANCEMENT; GAS-DETECTION; SENSITIVITY; SILVER; FILM;
D O I
10.3390/photonics6040108
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Surface plasmon resonance (SPR) sensors present a challenge when high sensitivity and small FWHM (full width at half maximum) are required to be achieved simultaneously. FWHM is defined by the difference between the two extreme values of the independent variable at which the value of the dependent variable is equal to half of its maximum. A smaller value of FWHM indicates better accuracy of SPR measurements. Theoretically, many authors have claimed the possibility of simultaneously achieving high sensitivity and small FWHM, which in most of the cases has been limited by experimental validation. In this report, an experimental study on the improved surface plasmon resonance (SPR) characteristics of gold over silver bimetallic sensor chips of different film thicknesses is presented. A comparative study of antigen-antibody interaction of the bimetallic chip using a custom-made, low-cost, and portable SPR device based on an angular interrogation scheme of Kretschmann configuration is performed. Pulsed direct current (DC) magnetron-sputtered bimetallic films of gold over silver were used in the construction of the SPR chip. The FWHM and sensitivity of the bimetallic sensors were firstly characterized using standard solutions of known refractive index which were later immobilized with monoclonal anti-immunoglobulin G (IgG) in the construction of the SPR biochip. Spectroscopic measurements such as ultraviolet-visible light spectroscopy (UV-Vis) and Fourier-transform infrared spectroscopy (FTIR) were used for the confirmation of the immobilization of the antibody. The performance of the bimetallic SPR biochip was investigated by exposing the sensor to various concentrations of the target protein. The results indicated that the bimetallic sensors of silver/gold had a 3.5-fold reduced FWHM compared to pure gold-based sensors, indicating a higher detection accuracy. In addition, they exhibited a significant shift in resonance angle as high as 8.5 +/- 0.2 due to antigen-antibody interaction, which was similar to 1.42-fold higher than observed for pure silver-based sensors.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] The surface plasmon resonance sensor with the metallic nanostructure for biosensing
    Lee, Byeong-Hyeon
    Oh, Geum-Yoon
    Kim, Hong-Seung
    Lee, Tae-Kyeong
    Kim, Seon-Hoon
    Ki, Hyun-Chul
    Kim, Doo-Gun
    Choi, Young-Wan
    PHOTONIC AND PHONONIC PROPERTIES OF ENGINEERED NANOSTRUCTURES II, 2012, 8269
  • [2] Surface plasmon resonance sensor based on bimetallic alloys grating
    A. Dhibi
    I. Sassi
    M. Oumezzine
    Indian Journal of Physics, 2016, 90 : 125 - 130
  • [3] Surface plasmon resonance sensor based on bimetallic alloys grating
    Dhibi, A.
    Sassi, I.
    Oumezzine, M.
    INDIAN JOURNAL OF PHYSICS, 2016, 90 (01) : 125 - 130
  • [4] Probabilistic evaluation of surface-enhanced localized surface plasmon resonance biosensing
    Yang, Heejin
    Lee, Wonju
    Hwang, Taewon
    Kim, Donghyun
    OPTICS EXPRESS, 2014, 22 (23): : 28412 - 28426
  • [5] Investigation of a Capillary-Based Surface Plasmon Resonance Sensor for Biosensing
    Liu, Yun
    Liu, Xiuxin
    Chen, Shimeng
    Liu, Qiang
    Peng, Wei
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2016, 34 (17) : 4036 - 4042
  • [6] Nanoparticle enhanced surface plasmon resonance biosensing: Application of gold nanorods
    Law, Wing-Cheung
    Yong, Ken-Tye
    Baev, Alexander
    Hu, Rui
    Prasad, Paras N.
    OPTICS EXPRESS, 2009, 17 (21): : 19041 - 19046
  • [7] Surface plasmon resonance imaging for biosensing
    Paul, S.
    Vadgama, P.
    Ray, A. K.
    IET NANOBIOTECHNOLOGY, 2009, 3 (03) : 71 - 80
  • [8] Airborne surface plasmon resonance biosensing
    Chinowsky, T
    Naimushin, A
    Soelberg, S
    Spinelli, C
    Kauffman, P
    Yee, S
    Furlong, C
    ENVIRONMENTAL MONITORING AND REMEDIATION III, 2004, 5270 : 182 - 188
  • [9] Development of a Surface-Plasmon Resonance Sensor Testbed for Bimetallic Sensors
    Babu, Roshni S.
    Colenso, Hamish R.
    Gouws, Gideon J.
    Auguie, Baptiste
    Moore, Ciaran P.
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 927 - 932
  • [10] Surface Plasmon Resonance Sensor Based on a Planar Waveguide with a Bimetallic Layer
    Rodrigues, Hudson J. B.
    Cardoso, Markos P.
    Miranda, Caua C.
    Romeiro, Amanda F.
    Giraldi, M. Thereza R.
    Silva, Anderson O.
    Costa, Joao C. W. A.
    Santos, Jose L.
    Guerreiro, Ariel
    2024 LATIN AMERICAN WORKSHOP ON OPTICAL FIBER SENSORS, LAWOFS 2024, 2024,