Phased attenuation correction in respiration correlated PET/CT

被引:0
|
作者
Nagel, C
Dekker, A
Bosmans, G
Öllers, M
Minken, A
Lambin, P
Schäfers, K
Lang, N
机构
[1] Univ Hosp Maastricht, GROW, Maastricht, Netherlands
[2] Univ Hosp Munster, Munster, Germany
关键词
D O I
10.1118/1.1997521
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluate the potential of phased attenuation correction in respiration correlated PET/CT. Method and Materials: Respiration correlated scans were made on a Siemens Biograph PET/CT scanner which was modified to make an extremely low pitch CT scan and list mode PET scan possible. After collection of the raw CT, list mode PET data, and the respiration signal via a pressure load cell, PET/CT images were binned into ten phases of the respiration with help of in‐house built software. Attenuation correction was next performed for each phase. Experiments were performed with a lollypop phantom. The sphere at the end of the rod was filled with approximately 20MBq FDG. For the first experiment a sphere with a diameter of 3.3cm was used. The second experiment was performed with a large sphere with a diameter of 3.7cm in which a second smaller sphere of 2.2cm was situated. The inner sphere was filled with water or air in order to simulate a tumor with a necrotic core. The sphere movement had an amplitude of 5.0cm, and a frequency of 0.3Hz. Results: Both CT and PET images of the ten phases in the first experiment show well‐defined spheres in all orthogonal directions. In phased PET images corrected with the phased CT data, the sphere has a clearer outline as compared to images that were corrected with uncorrelated CT data. The images of the second experiment indicate that phased attenuation correction also results in a better detection of inhomogeneous structures. Conclusion: In this phantom study we have shown that phased attenuation correction after respiration correlation of CT and PET is feasible. Application of phased attenuation correction reduces motion artifacts and improves image quality. In future research the feasibility of phased attenuation correction in PET/CT for lung cancer patients will be examined. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1913 / 1913
页数:1
相关论文
共 50 条
  • [31] Brain PET Attenuation Correction without CT: An Investigation
    Dewan, Maneesh
    Zhan, Yiqiang
    Hermosillo, Gerardo
    Jian, Bing
    Zhou, Xiang Sean
    2013 3RD INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION IN NEUROIMAGING (PRNI 2013), 2013, : 110 - 113
  • [32] Correction of respiration induced motion artifacts and activity-attenuation mismatch in free-breathing PET/CT
    Wang, Jizhe
    Feng, Tao
    Dong, Yun
    Li, Hongdi
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [33] Respiration-averaged CT versus standard CT attenuation maps for correction of the 18F-NaF uptake in hybrid PET/CT
    Tzolos, Evangelos
    Lassen, Martin Lyngby
    Pan, Tinsu
    Kwiecinski, Jacek
    Sebastien, Cadet
    Dey, Damini
    Berman, Daniel
    Slomka, Piotr
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [34] Ultra-low dose CT attenuation correction for PET/CT
    Xia, Ting
    Alessio, Adam M.
    De Man, Bruno
    Manjeshwar, Ravindra
    Asma, Evren
    Kinahan, Paul E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (02): : 309 - 328
  • [35] Evaluation of iterative reconstruction of CT images for attenuation correction in PET/CT
    Gebhard, Mark
    Kemp, Brad
    Lowe, Val
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [36] Ultra-low dose CT attenuation correction for PET/CT
    Xia, Ting
    Alessio, Adam
    De Man, Bruno
    Manjeshwar, Ravindra
    Asma, Evren
    Kinahan, Paul
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [37] Method for transforming CT images for attenuation correction in PET/CT imaging
    Carney, JPJ
    Townsend, DW
    Rappoport, V
    Bendriem, B
    MEDICAL PHYSICS, 2006, 33 (04) : 976 - 983
  • [38] Respiration-induced attenuation artifact at PET/CT: Technical considerations
    Goerres, GW
    Burger, C
    Kamel, E
    Seifert, B
    Kaim, AH
    Buck, A
    Buehler, TC
    von Schulthess, GK
    RADIOLOGY, 2003, 226 (03) : 906 - 910
  • [39] Positron emission tomography (PET) attenuation correction artefacts in PET/CT and PET/MRI
    Buchbender, C.
    Hartung-Knemeyer, V.
    Forsting, M.
    Antoch, G.
    Heusner, T. A.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1025):
  • [40] Attenuation correction in cardiac PET/CT with three different CT protocols: a comparison with conventional PET
    Souvatzoglou, Michael
    Bengel, Frank
    Busch, Raymonde
    Kruschke, Coletta
    Fernolendt, Helga
    Lee, Denise
    Schwaiger, Markus
    Nekolla, Stephan G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (12) : 1991 - 2000