Phased attenuation correction in respiration correlated PET/CT

被引:0
|
作者
Nagel, C
Dekker, A
Bosmans, G
Öllers, M
Minken, A
Lambin, P
Schäfers, K
Lang, N
机构
[1] Univ Hosp Maastricht, GROW, Maastricht, Netherlands
[2] Univ Hosp Munster, Munster, Germany
关键词
D O I
10.1118/1.1997521
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluate the potential of phased attenuation correction in respiration correlated PET/CT. Method and Materials: Respiration correlated scans were made on a Siemens Biograph PET/CT scanner which was modified to make an extremely low pitch CT scan and list mode PET scan possible. After collection of the raw CT, list mode PET data, and the respiration signal via a pressure load cell, PET/CT images were binned into ten phases of the respiration with help of in‐house built software. Attenuation correction was next performed for each phase. Experiments were performed with a lollypop phantom. The sphere at the end of the rod was filled with approximately 20MBq FDG. For the first experiment a sphere with a diameter of 3.3cm was used. The second experiment was performed with a large sphere with a diameter of 3.7cm in which a second smaller sphere of 2.2cm was situated. The inner sphere was filled with water or air in order to simulate a tumor with a necrotic core. The sphere movement had an amplitude of 5.0cm, and a frequency of 0.3Hz. Results: Both CT and PET images of the ten phases in the first experiment show well‐defined spheres in all orthogonal directions. In phased PET images corrected with the phased CT data, the sphere has a clearer outline as compared to images that were corrected with uncorrelated CT data. The images of the second experiment indicate that phased attenuation correction also results in a better detection of inhomogeneous structures. Conclusion: In this phantom study we have shown that phased attenuation correction after respiration correlation of CT and PET is feasible. Application of phased attenuation correction reduces motion artifacts and improves image quality. In future research the feasibility of phased attenuation correction in PET/CT for lung cancer patients will be examined. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1913 / 1913
页数:1
相关论文
共 50 条
  • [21] Interpolated average CT for cardiac PET/CT attenuation correction
    Mok, Greta S. P.
    Ho, Cobie Y. T.
    Yang, Bang-Hung
    Wu, Tung-Hsin
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (05) : 1072 - 1079
  • [22] Interpolated average CT for cardiac PET/CT attenuation correction
    Greta S. P. Mok
    Cobie Y. T. Ho
    Bang-Hung Yang
    Tung-Hsin Wu
    Journal of Nuclear Cardiology, 2016, 23 : 1072 - 1079
  • [23] Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging
    Nyflot, Matthew J.
    Lee, Tzu-Cheng
    Alessio, Adam M.
    Wollenweber, Scott D.
    Stearns, Charles W.
    Bowen, Stephen R.
    Kinahan, Paul E.
    MEDICAL PHYSICS, 2015, 42 (01) : 110 - 120
  • [24] Phased Versus Midventilation Attenuation-Corrected Respiration-Correlated PET for Patients with Non-Small Cell Lung Cancer
    Rosario, Tezontl
    Ollers, Michel C.
    Bosmans, Geert
    De Ruysscher, Dirk
    Lambin, Philippe
    Dekker, Andre
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2009, 37 (04) : 208 - 214
  • [25] Reduction of attenuation correction artifacts in PET-CT
    Nuyts, Johan
    Stroobants, Sigrid
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1895 - 1899
  • [26] Sinogram-based attenuation correction in PET/CT
    Yang, Qingsong
    Lu, Yang
    Xi, Yan
    Cong, Wenxiang
    Kalra, Mannudeep
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (01) : 9 - 22
  • [27] CT Based Attenuation Correction for PET Brain Imaging
    Lokitz, Stephen J.
    Coleman, R. Edward
    Yoshizumi, Terry T.
    Toncheva, Greta I.
    Daigle, Lauren T.
    Colsher, James G.
    Turkington, Timothy G.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3320 - 3325
  • [28] Automatic alignment of PET/CT attenuation correction maps
    Slomka, Piotr
    Diaz-Zamudio, Mariana
    Dey, Damini
    Brodov, Yafim
    Choi, David
    Germano, Guido
    Hayes, Sean
    Friedman, John
    Thomson, Louise
    Berman, Daniel
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [29] Analysis of Optimal CT Spectrum for PET Attenuation Correction
    Rui, Xue
    Long, Yong
    Asma, Evren
    Alessio, Adam
    Kinahan, Paul
    De Man, Bruno
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [30] Automatic Registration of Cardiac PET/CT for Attenuation Correction
    Bond, Sarah
    Kadir, Timor
    Hamill, James
    Casey, Michael
    Platsch, Guenther
    Burckhardt, Darrell
    Eisner, Robert
    Kaustubh, Navin
    Declerck, Jerome
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4785 - +