A measurement of the fast-neutron sensitivity of a Geiger-Muller detector in the pulsed neutron beam from a superconducting cyclotron

被引:9
|
作者
Maughan, RL [1 ]
Yudelev, M [1 ]
Kota, C [1 ]
机构
[1] WAYNE STATE UNIV, DETROIT, MI 48230 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1996年 / 41卷 / 08期
关键词
D O I
10.1088/0031-9155/41/8/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The k(U) value of a commercially available miniature energy compensated Geiger-Muller (GM) detector has been determined using the modified lead attenuation method of Hough. The measurements were made in a d(48.5)-Be neutron beam produced by the superconducting cyclotron based neutron therapy facility at Harper Hospital. The unique problems associated with making measurements in a 2 ms duration pulsed beam with a 20% duty cycle are discussed. The beam monitoring system, which allows the beam pulse shape at low beam intensities to be measured, is described. By gating the GM output with a discriminator pulse derived from the beam pulse shape, the gamma-ray count rates and dead-time corrections within the 2 ms pulse and between pulses can be measured separately. The k(U) value of (0.0245 +/- 0.0015) determined for this GM detector is consistent with the values measured by other workers with identical and similar detectors in neutron beams with comparable, but not identical, neutron spectra.
引用
收藏
页码:1341 / 1351
页数:11
相关论文
共 48 条
  • [21] Single-crystal diamond detector for time-resolved measurements of a pulsed fast-neutron beam
    Pietropaolo, A.
    Andreani, C.
    Rebai, M.
    Giacomelli, L.
    Gorini, G.
    Cippo, E. Perelli
    Tardocchi, M.
    Fazzi, A.
    Rinati, G. Verona
    Verona, C.
    Marinelli, M.
    Milani, E.
    Frost, C. D.
    Schooneveld, E. M.
    EPL, 2010, 92 (06)
  • [22] PRELIMINARY DOSE MEASUREMENTS IN FAST-NEUTRON BEAM AT CYCLOTRON OF UNIVERSITY-OF-LOUVAIN
    PARMENTIER, N
    CHEMTOB, M
    RICOURT, A
    MEULDERS, JP
    JONGEN, Y
    DEBAUCHE, A
    WAMBERSIE, A
    EUROPEAN JOURNAL OF CANCER, 1974, 10 (05) : 322 - 323
  • [23] FAST-NEUTRON FLUX MEASUREMENT WITH A LITHIUM-DRIFTED GERMANIUM DETECTOR
    SMITH, DL
    NUCLEAR INSTRUMENTS & METHODS, 1972, 102 (02): : 193 - &
  • [24] MEASUREMENT OF FAST-NEUTRON AND THERMAL-NEUTRON FLUXES USING A SMALL LII (EU) CRYSTAL DETECTOR
    NGUYEN, DH
    BENNETT, RG
    NUCLEAR TECHNOLOGY, 1972, 14 (03) : 284 - &
  • [25] PHYSICAL CHARACTERISTICS OF FAST-NEUTRON BEAMS FROM A COMPACT MEDICAL CYCLOTRON
    SKAGGS, LS
    KUCHNIR, FT
    HARPER, PV
    GRIEM, ML
    RADIOLOGY, 1974, 111 (02) : 471 - 472
  • [26] ZNS+B SCINTILLATION COUNTER AS THRESHOLD DETECTOR OF A PULSED FAST-NEUTRON FLUX
    KOLESOV, BM
    OVCHINNI.AK
    KHAIKOVI.IM
    GANICHEV, GI
    TIMOFEEV.TV
    PODPOYAS.VA
    GUBANOV, VG
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (04): : 82 - 84
  • [27] NEUTRON BEAM FACILITY AT LOUVAIN-LA-NEUVE ISOCHRONOUS CYCLOTRON - CROSS-SECTIONS FOR FAST-NEUTRON PRODUCTION
    BOSMAN, M
    LELEUX, P
    LIPNIK, P
    MACQ, P
    MEULDERS, JP
    PETIT, R
    PIRART, C
    VALENDUC, G
    NUCLEAR INSTRUMENTS & METHODS, 1978, 148 (02): : 363 - 367
  • [28] PULSED NEUTRON INTENSITY FROM RECTANGULAR SHAPED LIGHT WATER MODERATOR WITH FAST-NEUTRON REFLECTOR
    KIYANAGI, Y
    IWASA, H
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1982, 19 (05) : 352 - 358
  • [29] Neutron Flux Measurement Using a Fast-Neutron Scintillation Detector with High Temporal Resolution on the Large Helical Device
    Ogawa, Kunihiro
    Isobe, Mitsutaka
    Kawase, Hiroki
    Nishitani, Takeo
    PLASMA AND FUSION RESEARCH, 2018, 13
  • [30] Neutron flux measurement using a fast-neutron scintillation detector with high temporal resolution on the large helical device
    Ogawa K.
    Isobe M.
    Kawase H.
    Nishitani T.
    Plasma and Fusion Research, 2018, 13