Neutron H*(10) estimation and measurements around 18 MV linac

被引:8
|
作者
Ceron Ramirez, Pablo Victor [1 ]
Diaz Gongora, Jose Antonio Iran [1 ]
Paredes Gutierrez, Lydia Concepcion [2 ]
Rivera Montalvo, Teodoro [1 ]
Vega Carrillo, Hector Rene [3 ]
机构
[1] Inst Politecn Nacl, Ctr Invest Ciencia Aplicada & Tecnol, Calzada Legaria 694, Avanzada Legaria 11500, Mexico
[2] Inst Nacl Invest Nucl, Carretera Mexico Toluca S-N, Ocoyoacac, Mexico
[3] Univ Autonoma Zacatecas, Unidad Acad Estudios Nucl, Apdo Postal 336, Zacatecas 98000, Mexico
关键词
Neutron dosimetry; LINAC; Monte Carlo; MONTE-CARLO; DOSE-EQUIVALENT; PHOTONEUTRONS; SPECTRA; PAIRS; BEAM;
D O I
10.1016/j.apradiso.2016.05.006
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Thermoluminescent dosimetry, analytical techniques and Monte Carlo calculations were used to estimate the dose of neutron radiation in a treatment room with a linear electron accelerator of 18 MV. Measurements were carried out through neutron ambient dose monitors which include pairs of thermo-luminescent dosimeters TLD 600 ((LiF)-Li-6: Mg, Ti) and TLD 700 ((LiF)-Li-7: Mg, Ti), which were placed inside a paraffin spheres. The measurements has allowed to use NCRP 151 equations, these expressions are useful to find relevant dosimetric quantities. In addition, photoneutrons produced by linac head were calculated through MCNPX code taking into account the geometry and composition of the linac head principal parts. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2 / 7
页数:6
相关论文
共 50 条
  • [31] A Neutron Measurement Comparison of Varian and Elekta 10&18 MV Photon Beams
    Chen, K.
    Klein, E.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [32] Photonuclear isotope characterization of a Siemens KDS 18 MV linac head
    Roig, M
    Panettieri, V
    Ginjaume, M
    Sánchez-Reyes, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : N243 - N246
  • [33] AN INVESTIGATION OF PHOTONUCLEAR REACTIONS IN CERROBEND EUTECTIC MATERIAL WITH AN 18 MV LINAC
    BORCHARDT, IM
    PATTERSON, JR
    BEDDOE, AH
    SORELL, GC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (05): : 649 - 653
  • [34] LINAC MEASUREMENTS OF FAST NEUTRON RESPONSE OF ORGANIC SCINTILLATORS
    YATES, E
    CRANDALL, D
    KIRKBRIDE, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1967, NS14 (01) : 372 - +
  • [35] Monte Carlo estimation of photoneutrons spectra and dose equivalent around an 18 MV medical linear accelerator
    Alem-Bezoubiri, A.
    Bezoubiri, F.
    Badreddine, A.
    Mazrou, H.
    Lounis-Mokrani, Z.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 97 : 381 - 392
  • [36] In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing 18 MV IMRT
    Reft, Chester S.
    Runkel-Muller, Renate
    Myrianthopoulos, Leon
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3734 - 3742
  • [37] Neutron dose in and out of 18 MV photon fields
    Ezzati, A. O.
    Studenski, M. T.
    [J]. APPLIED RADIATION AND ISOTOPES, 2017, 122 : 186 - 192
  • [38] Treatment planning for a 6MV FFF Halcyon linac as a replacement for a 10MV-capable Clinac
    Withers, D.
    Kidane, G.
    Farmakidis, D.
    Crees, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1073 - S1073
  • [39] MEASUREMENTS OF INDUCED RADIOACTIVITY IN DUST AROUND A 400 MEV LINAC
    LUCCI, F
    MEROLLI, S
    PELLICCIONI, M
    [J]. HEALTH PHYSICS, 1973, 24 (04): : 411 - 415
  • [40] Comparison and estimation of photoneutron dose produce between 10 MV flattened and unflattened beam in Elekta Versa HD™ medical linac
    Khilafath, Hajee Reyaz Ali Sahib
    Ganesan, Bharanidharan
    Sekar, Nandakumar
    Mohapatra, Dinakrushna
    Vellingiri, Jayaprakash
    Prakasarao, Aruna
    Mahadevan, Pramod
    Singaravelu, Ganesan