Does Pelvic Orientation Influence Wear Measurement of the Acetabular Cup in Total Hip Arthroplasty-An Experimental Study

被引:3
|
作者
Wu, Junzhe [1 ,2 ]
Taylor, Dominic [3 ]
Forst, Raimund [1 ]
Seehaus, Frank [1 ,4 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Fac Med, Dept Orthopaed Surg, D-91054 Erlangen, Germany
[2] Fujian Med Univ, Affiliated Hosp 2, Dept Orthopaed Surg, Quanzhou 362000, Peoples R China
[3] Hosp Coburg, Dept Orthopaed & Trauma Surg, D-96450 Coburg, Germany
[4] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Trauma & Orthopaed Surg, D-91054 Erlangen, Germany
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 21期
关键词
polyethylene wear; roentgen stereophotogrammetric analysis; total hip arthroplasty; precision; accuracy; pelvic orientation; POLYETHYLENE WEAR; RADIOGRAPHIC METHODS; FOLLOW-UP; ACCURACY; VALIDATION; LONG;
D O I
10.3390/app112110014
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Roentgen stereophotogrammetric analysis (RSA) is the gold standard to detect in vivo material wear of the bearing couples in hip arthroplasty. Some surgical planning tools offer the opportunity to detect wear by using standard a.p. radiographs (2D(wear)), whilst RSA (3D(wear)) needs a special radiological setup. The aims of this study are to prove the interchangeable applicability of a 2D(wear) approach next to RSA and to assess the influence of different pelvic positions on measurement outcomes. An implant-bone model was used to mimic three different wear scenarios in seven pelvic-femur alignment positions. RSA and a.p. radiographs of the reference and a follow-up (simulated wear) pose were acquired. Accuracy and precision were worse for the 2D(wear) approach (0.206 mm; 0.159 mm) in comparison to the 3D(wear) approach (0.043 mm; 0.017 mm). Changing the pelvic position significantly influenced the 2D(wear) results (4 of 7, p < 0.05), whilst 3D(wear) results showed almost no change. The 3D(wear) is superior to the 2D(wear) approach, as it is less susceptible to changes in pelvic position. However, the results suggest that a 2D(wear) approach may be an alternative method if the wear present is in the range of 100-500 mu m and a.p. radiographs are available with the pelvis projected in a neutral position.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] The transverse acetabular ligament may be used to align the acetabular cup in total hip arthroplasty
    Pearce, C. J.
    Sexton, S. A.
    Davies, D. C.
    Khaleel, A.
    HIP INTERNATIONAL, 2008, 18 (01) : 7 - 10
  • [32] Minimal Radiation Dose Computed Tomography for Measurement of Cup Orientation in Total Hip Arthroplasty
    Arai, Noriyuki
    Nakamura, Shigeru
    Matsushita, Takashi
    Suzuki, Shigeru
    JOURNAL OF ARTHROPLASTY, 2010, 25 (02): : 263 - 267
  • [33] Precision of acetabular cup placement in robotic integrated total hip arthroplasty
    Elson, Leah
    Dounchis, Jon
    Illgen, Richard
    Marchand, Robert C.
    Padgett, Douglas E.
    Bragdon, Charles R.
    Malchau, Henrik
    HIP INTERNATIONAL, 2015, 25 (06) : 531 - 536
  • [34] Oblong Acetabular Cup, Type TC, for Revision Total Hip Arthroplasty
    Trc, T.
    Stastny, E.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2012, 79 (06) : 506 - 511
  • [35] Research Synthesis of Recommended Acetabular Cup Orientations for Total Hip Arthroplasty
    Harrison, Claire L.
    Thomson, Avril I.
    Cutts, Steven
    Rowe, Philip J.
    Riches, Philip E.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 377 - 382
  • [36] Dual mobility acetabular cup for total hip arthroplasty: use with caution
    Vahedi, Hamed
    Makhdom, Asim M.
    Parvizi, Javad
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (03) : 237 - 243
  • [37] Biomechanical Evaluation of Acetabular Cup Implantation in Cementless Total Hip Arthroplasty
    Margalit, Kate A.
    Hayashi, Kei
    Jackson, Josh
    Kim, Sun Young
    Garcia, Tanya C.
    Wiggans, K. Tomo
    Aiken, Sean
    Stover, Susan M.
    VETERINARY SURGERY, 2010, 39 (07) : 818 - 823
  • [38] Acetabular Cup Design Influences Deformational Response in Total Hip Arthroplasty
    Meding, John B.
    Small, Scott R.
    Jones, Mary E.
    Berend, Michael E.
    Ritter, Merrill A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (02) : 403 - 409
  • [39] ACETABULAR CUP-SITING DEVICE FOR TOTAL HIP-ARTHROPLASTY
    DOYLE, J
    MURRAY, P
    MAHONY, PO
    FARMER, M
    HOOPER, AC
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1989, 108 (05) : 317 - 321
  • [40] Sagittal Imbalance Does Not Influence Cup Anteversion in Total Hip Arthroplasty Dislocations
    Haws, Brittany E.
    Khechen, Benjamin
    Patel, Dil, V
    Louie, Philip K.
    Iyer, Sravisht
    Cardinal, Kaitlyn L.
    Guntin, Jordan A.
    Singh, Kern
    CLINICAL SPINE SURGERY, 2019, 32 (01): : E31 - E36