Does Pelvic Orientation Influence Wear Measurement of the Acetabular Cup in Total Hip Arthroplasty-An Experimental Study

被引:3
|
作者
Wu, Junzhe [1 ,2 ]
Taylor, Dominic [3 ]
Forst, Raimund [1 ]
Seehaus, Frank [1 ,4 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Fac Med, Dept Orthopaed Surg, D-91054 Erlangen, Germany
[2] Fujian Med Univ, Affiliated Hosp 2, Dept Orthopaed Surg, Quanzhou 362000, Peoples R China
[3] Hosp Coburg, Dept Orthopaed & Trauma Surg, D-96450 Coburg, Germany
[4] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Trauma & Orthopaed Surg, D-91054 Erlangen, Germany
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 21期
关键词
polyethylene wear; roentgen stereophotogrammetric analysis; total hip arthroplasty; precision; accuracy; pelvic orientation; POLYETHYLENE WEAR; RADIOGRAPHIC METHODS; FOLLOW-UP; ACCURACY; VALIDATION; LONG;
D O I
10.3390/app112110014
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Roentgen stereophotogrammetric analysis (RSA) is the gold standard to detect in vivo material wear of the bearing couples in hip arthroplasty. Some surgical planning tools offer the opportunity to detect wear by using standard a.p. radiographs (2D(wear)), whilst RSA (3D(wear)) needs a special radiological setup. The aims of this study are to prove the interchangeable applicability of a 2D(wear) approach next to RSA and to assess the influence of different pelvic positions on measurement outcomes. An implant-bone model was used to mimic three different wear scenarios in seven pelvic-femur alignment positions. RSA and a.p. radiographs of the reference and a follow-up (simulated wear) pose were acquired. Accuracy and precision were worse for the 2D(wear) approach (0.206 mm; 0.159 mm) in comparison to the 3D(wear) approach (0.043 mm; 0.017 mm). Changing the pelvic position significantly influenced the 2D(wear) results (4 of 7, p < 0.05), whilst 3D(wear) results showed almost no change. The 3D(wear) is superior to the 2D(wear) approach, as it is less susceptible to changes in pelvic position. However, the results suggest that a 2D(wear) approach may be an alternative method if the wear present is in the range of 100-500 mu m and a.p. radiographs are available with the pelvis projected in a neutral position.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Influence of acetabular cup thickness on seating and primary stability in total hip arthroplasty
    Ruhr, Miriam
    Baetz, Johanna
    Pueschel, Klaus
    Morlock, Michael M.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (09) : 2139 - 2146
  • [22] Measurement of acetabular cup inclination in anteroposterior pelvic radiogram. An indicator of quality after primary total hip arthroplasty?
    Loitsch, T.
    Freitag, T.
    Leucht, F.
    Reichel, H.
    Bieger, R.
    ORTHOPADE, 2018, 47 (12): : 1003 - 1007
  • [23] Assessment of Accuracy of Acetabular Cup Orientation in CT-free Navigated Total Hip Arthroplasty
    Fukunishi, Shigeo
    Fukui, Tomokazu
    Imamura, Fumiaiki
    Nishio, Shoji
    Shibanuma, Nao
    Yoshiya, Shinichi
    ORTHOPEDICS, 2008, 31 (10) : 987 - 987
  • [24] The relationship of the orientation of the transverse acetabular ligament and acetabular labrum to the suggested safe zones of cup positioning in total hip arthroplasty
    Archbold, H. A. P.
    Slomczykowski, M.
    Crone, M.
    Eckman, K.
    Jaramaz, B.
    Beverland, D. E.
    HIP INTERNATIONAL, 2008, 18 (01) : 1 - 6
  • [25] Influence of Pelvic Tilt on Polyethylene Wear after Total Hip Arthroplasty
    Tezuka, Taro
    Inaba, Yutaka
    Kobayashi, Naomi
    Ike, Hiroyuki
    Kubota, So
    Kawamura, Masaki
    Saito, Tomoyuki
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [26] Changes in acetabular orientation during total hip arthroplasty
    Schloemann, D. T.
    Edelstein, A., I
    Barrack, R. L.
    BONE & JOINT JOURNAL, 2019, 101B (06): : 45 - 50
  • [27] Anatomic referencing of cup orientation in total hip arthroplasty
    Tannast, M
    Langlotz, U
    Siebenrock, KA
    Wiese, M
    Bernsmann, K
    Langlotz, F
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) : 144 - 150
  • [28] COMPUTED-TOMOGRAPHY MEASUREMENT OF ACETABULAR CUP ANTEVERSION AND RETROVERSION IN TOTAL HIP-ARTHROPLASTY
    MIAN, SW
    TRUCHLY, G
    PFLUM, FA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (276) : 206 - 209
  • [29] Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?
    Benjamin Craiovan
    Tobias Renkawitz
    Markus Weber
    Joachim Grifka
    Lutz Nolte
    Guoyan Zheng
    International Orthopaedics, 2014, 38 : 2009 - 2015
  • [30] Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?
    Craiovan, Benjamin
    Renkawitz, Tobias
    Weber, Markus
    Grifka, Joachim
    Nolte, Lutz
    Zheng, Guoyan
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (10) : 2009 - 2015