Neodymium:YAG laser damage threshold of foldable intraocular lenses

被引:28
|
作者
Trinavarat, A [1 ]
Atchaneeyasakul, LO [1 ]
Udompunturak, S [1 ]
机构
[1] Mahidol Univ, Siriraj Hosp, Dept Ophthalmol, Bangkok 10700, Thailand
来源
关键词
D O I
10.1016/S0886-3350(00)00855-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the energy level of the neodymium:YAG (Nd,YAG) laser that induced a 50% incidence of intraocular lens (IOL) damage in 5 foldable IOL materials. Setting: Department of Ophthalmology, Siriraj Hospital Mahidol University, Bangkok, Thailand. Methods: To simulate the condition within the capsular bag, an IOL was sandwiched between 2 rubber membranes. The front membrane had a central opening mimicking the anterior capsulotomy; the back membrane acted as the posterior capsule. The model was submerged in a water-filled chamber. The Nd:YAG laser with an automatic focus 150 mum beyond the focus of the aiming beam was used to perform a posterior capsulotomy. Three IOLs of each of 5 foldable IOL materials were tested. One type of poly(methyl methacrylate) (PMMA) was studied as a reference. The incidence of IOL damage at various energy levels was recorded. linear regression analysis was used to determine the 50% incidence damage threshold. Results: The 6 materials tested included 1 silicone lens (SI-40NB, AMO), 1 hydrophobic acrylic lens (MA60BM, Alcon), 3 hydrophilic acrylic lenses (Haptibag Ang, IOLtech; ACR6D, Corneal; H60M, Bausch & Lomb), acid 1 PMMA lens (LX10BD, Alcon). The 50% incidence damage threshold values were 0.37 mJ, 0.54 mJ, 0.58 mJ, 0.52 mJ, 0.66 mJ, and 0.68 mJ, respectively. Conclusions: The 50% incidence damage threshold in all the IOLs was below the energy level normally used to perform a posterior capsulotomy in clinical practice. However, setting the laser at the lowest possible energy, focusing the laser beam beyond the posterior capsule, and performing the capsulotomy early should minimize the risk of IOL damage.
引用
收藏
页码:775 / 780
页数:6
相关论文
共 50 条
  • [21] Neodymium:YAG membranectomy for pupillary membranes on posterior chamber intraocular lenses
    Gandham, SB
    Brown, RH
    Katz, LJ
    Lynch, MG
    OPHTHALMOLOGY, 1995, 102 (12) : 1846 - 1852
  • [22] Effect of square-edged intraocular lenses on neodymium: YAG laser capsulotomy rates in the United States
    Cleary, Georgia
    Spalton, David J.
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11): : 1899 - 1906
  • [23] Intraocular lens haptic fracturing with the neodymium:YAG laser
    Kocak, N
    Saatci, AO
    Celik, L
    Durak, I
    Kaynak, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (04): : 662 - 665
  • [24] A NEW FORM OF DAMAGE TO PMMA INTRAOCULAR LENSES BY ND-YAG LASER PHOTODISRUPTORS
    MELLERIO, J
    CAPON, MRC
    DOCCHIO, F
    SLINEY, D
    KRAFFT, J
    EYE, 1988, 2 : 376 - 381
  • [25] Intraocular lens pupillary capture after neodymium:YAG laser treatment of interlenticular opacification of posterior chamber piggyback intraocular lenses
    Park, Soo
    Ressiniotis, Thomas
    Wood, Chris
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06): : 1056 - 1058
  • [26] A COMPARISON OF ND-YAG LASER DAMAGE THRESHOLDS FOR PMMA AND SILICONE INTRAOCULAR LENSES
    BATH, PE
    ROMBERGER, AB
    BROWN, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1986, 27 (05) : 795 - 798
  • [27] Cost effectiveness of foldable multifocal intraocular lenses compared to foldable monofocal intraocular lenses for cataract surgery
    Dolders, MGT
    Nijkamp, MD
    Nuijts, RMMA
    van den Borne, B
    Hendrikse, F
    Ament, A
    Groot, W
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (09) : 1163 - 1168
  • [28] The materials for intraocular lenses. II: silicone foldable intraocular lenses
    Werner, JP
    Legeais, JM
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1999, 22 (04): : 492 - 501
  • [29] Analysis of YAG Laser-Induced Damage in Intraocular Lenses: Characterization of Optical and Surface Properties of YAG Shots
    Borkenstein, Andreas F.
    Borkenstein, Eva-Maria
    OPHTHALMIC RESEARCH, 2021, 64 (03) : 417 - 431
  • [30] CORNEAL ENDOTHELIAL DAMAGE WITH NEODYMIUM - YAG LASER
    MEYER, KT
    PETTIT, TH
    STRAATSMA, BR
    OPHTHALMOLOGY, 1984, 91 (09) : 1022 - 1028