Neodymium:YAG laser damage threshold of foldable intraocular lenses

被引:28
|
作者
Trinavarat, A [1 ]
Atchaneeyasakul, LO [1 ]
Udompunturak, S [1 ]
机构
[1] Mahidol Univ, Siriraj Hosp, Dept Ophthalmol, Bangkok 10700, Thailand
来源
关键词
D O I
10.1016/S0886-3350(00)00855-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the energy level of the neodymium:YAG (Nd,YAG) laser that induced a 50% incidence of intraocular lens (IOL) damage in 5 foldable IOL materials. Setting: Department of Ophthalmology, Siriraj Hospital Mahidol University, Bangkok, Thailand. Methods: To simulate the condition within the capsular bag, an IOL was sandwiched between 2 rubber membranes. The front membrane had a central opening mimicking the anterior capsulotomy; the back membrane acted as the posterior capsule. The model was submerged in a water-filled chamber. The Nd:YAG laser with an automatic focus 150 mum beyond the focus of the aiming beam was used to perform a posterior capsulotomy. Three IOLs of each of 5 foldable IOL materials were tested. One type of poly(methyl methacrylate) (PMMA) was studied as a reference. The incidence of IOL damage at various energy levels was recorded. linear regression analysis was used to determine the 50% incidence damage threshold. Results: The 6 materials tested included 1 silicone lens (SI-40NB, AMO), 1 hydrophobic acrylic lens (MA60BM, Alcon), 3 hydrophilic acrylic lenses (Haptibag Ang, IOLtech; ACR6D, Corneal; H60M, Bausch & Lomb), acid 1 PMMA lens (LX10BD, Alcon). The 50% incidence damage threshold values were 0.37 mJ, 0.54 mJ, 0.58 mJ, 0.52 mJ, 0.66 mJ, and 0.68 mJ, respectively. Conclusions: The 50% incidence damage threshold in all the IOLs was below the energy level normally used to perform a posterior capsulotomy in clinical practice. However, setting the laser at the lowest possible energy, focusing the laser beam beyond the posterior capsule, and performing the capsulotomy early should minimize the risk of IOL damage.
引用
收藏
页码:775 / 780
页数:6
相关论文
共 50 条
  • [1] NEODYMIUM - YAG LASER DAMAGE OF INTRAOCULAR LENSES
    SMITH, SG
    SNOWDEN, FM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (06): : 660 - 663
  • [2] Damage in various intraocular lenses by Neodymium:YAG laser photodisruption
    Dick, B
    Schwenn, O
    Pfeiffer, N
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1997, 211 (04) : 263 - 271
  • [3] NEODYMIUM - YAG LASER DAMAGE THRESHOLD - A COMPARISON OF INJECTION-MOLDED AND LATHE-CUT POLYMETHYLMETHACRYLATE INTRAOCULAR LENSES
    WILSON, SE
    BRUBAKER, RF
    OPHTHALMOLOGY, 1987, 94 (01) : 7 - 11
  • [4] EFFECT OF NEODYMIUM - YAG LASER PHOTODISRUPTION ON INTRAOCULAR LENSES INVITRO
    JOO, CK
    KIM, JH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (06): : 562 - 566
  • [5] NEODYMIUM-YAG LASER DAMAGE ON SILICONE INTRAOCULAR LENSES - A COMPARISON OF LESIONS ON EXPLANTED LENSES AND EXPERIMENTALLY PRODUCED LESIONS
    NEWLAND, TJ
    AUFFARTH, GU
    WESENDAHL, TA
    APPLE, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (05): : 527 - 533
  • [6] COMPREHENSIVE STUDY OF DAMAGE TO INTRAOCULAR LENSES BY SINGLE AND MULTIPLE NANOSECOND NEODYMIUM - YAG LASER-PULSES
    CAPON, MRC
    DOCCHIO, F
    LEONI, G
    TRABUCCHI, G
    BRANCATO, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (05): : 603 - 610
  • [7] Neodymium:YAG laser posterior capsulotomy after implantation of AcrySof intraocular lenses
    Davison, JA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (07): : 1492 - 1500
  • [8] INTRAOCULAR-LENS DAMAGE FROM THE NEODYMIUM-YAG LASER
    CLAYMAN, HM
    KARRENBERG, FG
    PAREL, JM
    ANNALS OF OPHTHALMOLOGY, 1984, 16 (06): : 551 - &
  • [9] EFFECT OF TRANSSCLERAL NEODYMIUM - YAG CYCLOPHOTOCOAGULATION ON INTRAOCULAR LENSES
    BLOMQUIST, PH
    GROSS, RL
    KOCH, DD
    OPHTHALMIC SURGERY AND LASERS, 1990, 21 (03): : 223 - 226
  • [10] Damage of foldable intraocular lenses by incorrect folder forceps
    Baldeschi, L
    Rizzo, S
    Nardi, M
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (02) : 245 - 247