Accuracy of high-frequency oscillations recorded intraoperatively for classification of epileptogenic regions

被引:17
|
作者
Weiss, Shennan A. [1 ,2 ,3 ]
Staba, Richard J. [6 ]
Sharan, Ashwini [11 ]
Wu, Chengyuan [11 ]
Rubinstein, Daniel [10 ]
Das, Sandhitsu [12 ]
Waldman, Zachary [10 ]
Orosz, Iren [6 ]
Worrell, Gregory [4 ,5 ]
Engel, Jerome, Jr. [6 ,7 ,8 ,9 ]
Sperling, Michael R. [10 ]
机构
[1] State Univ New York Downstate, Dept Neurol, Brooklyn, NY 11203 USA
[2] State Univ New York Downstate, Dept Physiol & Pharmacol, Brooklyn, NY 11203 USA
[3] New York City Hlth Hosp, Dept Neurol, Brooklyn, NY USA
[4] Dept Neurol, Mayo Syst Elect Lab MSEL, Rochester, MI USA
[5] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[6] UCLA, David Geffen Sch Med, Dept Neurol, Los Angeles, CA 90095 USA
[7] UCLA, David Geffen Sch Med, Dept Neurobiol, Los Angeles, CA 90095 USA
[8] UCLA, David Geffen Sch Med, Dept Psychiat & Biobehavioral Sci, Los Angeles, CA 90095 USA
[9] UCLA, David Geffen Sch Med, Brain Res Inst, Los Angeles, CA 90095 USA
[10] Thomas Jefferson Univ, Dept Neurol & Neurosci, 901 Walnut St Suite 400, Philadelphia, PA 19107 USA
[11] Thomas Jefferson Univ, Dept Neurosurg, Philadelphia, PA 19107 USA
[12] Univ Penn, Penn Image Comp & Sci Lab, Philadelphia, PA 19143 USA
关键词
TEMPORAL-LOBE EPILEPSY; FAST RIPPLES; INTRACRANIAL EEG; SPIKE ACTIVITY; ELECTROCORTICOGRAPHY; SLEEP; SURGERY; REMIFENTANIL; SEVOFLURANE; DISCHARGES;
D O I
10.1038/s41598-021-00894-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To see whether acute intraoperative recordings using stereo EEG (SEEG) electrodes can replace prolonged interictal intracranial EEG (iEEG) recording, making the process more efficient and safer, 10 min of iEEG were recorded following electrode implantation in 16 anesthetized patients, and 1-2 days later during non-rapid eye movement (REM) sleep. Ripples on oscillations (RonO, 80-250 Hz), ripples on spikes (RonS), sharp-spikes, fast RonO (fRonO, 250-600 Hz), and fast RonS (fRonS) were semi-automatically detected. HFO power and frequency were compared between the conditions using a generalized linear mixed-effects model. HFO rates were compared using a two-way repeated measures ANOVA with anesthesia type and SOZ as factors. A receiver-operating characteristic (ROC) curve analysis quantified seizure onset zone (SOZ) classification accuracy, and the scalar product was used to assess spatial reliability. Resection of contacts with the highest rate of events was compared with outcome. During sleep, all HFOs, except fRonO, were larger in amplitude compared to intraoperatively (p < 0.01). HFO frequency was also affected (p < 0.01). Anesthesia selection affected HFO and sharp-spike rates. In both conditions combined, sharp-spikes and all HFO subtypes were increased in the SOZ (p < 0.01). However, the increases were larger during the sleep recordings (p < 0.05). The area under the ROC curves for SOZ classification were significantly smaller for intraoperative sharp-spikes, fRonO, and fRonS rates (p < 0.05). HFOs and spikes were only significantly spatially reliable for a subset of the patients (p < 0.05). A failure to resect fRonO areas in the sleep recordings trended the most sensitive and accurate for predicting failure. In summary, HFO morphology is altered by anesthesia. Intraoperative SEEG recordings exhibit increased rates of HFOs in the SOZ, but their spatial distribution can differ from sleep recordings. Recording these biomarkers during non-REM sleep offers a more accurate delineation of the SOZ and possibly the epileptogenic zone.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] High-frequency solar oscillations
    Jefferies, SM
    NEW EYES TO SEE INSIDE THE SUN AND STARS: PUSHING THE LIMITS OF HELIO- AND ASTEROSEISMOLOGY WITH NEW OBSERVATIONS FROM THE GROUND AND FROM SPACE, 1998, (185): : 415 - 422
  • [42] A Novel MEGNet for Classification of High-Frequency Oscillations in Magnetoencephalography of Epileptic Patients
    Liu, Jun
    Sun, Siqi
    Liu, Yang
    Guo, Jiayang
    Li, Hailong
    Gao, Yuan
    Sun, Jintao
    Xiang, Jing
    COMPLEXITY, 2020, 2020
  • [43] Epileptogenic high-frequency oscillations skip the motor area in children with multilobar drug-resistant epilepsy
    Iimura, Yasushi
    Jones, Kevin
    Hattori, Kyoko
    Okazawa, Yushi
    Noda, Atsuko
    Hoashi, Kana
    Nonoda, Yutaka
    Asano, Eishi
    Akiyama, Tomoyuki
    Go, Cristina
    Ochi, Ayako
    Snead, O. Carter, III
    Donner, Elizabeth J.
    Rutka, James T.
    Drake, James M.
    Otsubo, Hiroshi
    CLINICAL NEUROPHYSIOLOGY, 2017, 128 (07) : 1197 - 1205
  • [44] Frequency-independent characteristics of high-frequency oscillations in epileptic and non-epileptic regions
    Pail, Martin
    Rehulka, Pavel
    Cimbalnik, Jan
    Dolezalova, Irena
    Chrastina, Jan
    Brazdil, Milan
    CLINICAL NEUROPHYSIOLOGY, 2017, 128 (01) : 106 - 114
  • [45] High-Frequency Oscillations Recorded on the Scalp of Patients With Epilepsy Using Tripolar Concentric Ring Electrodes
    Besio, Walter G.
    Martinez-Juarez, Iris E.
    Makeyev, Oleksandr
    Gaitanis, John N.
    Blum, Andrew S.
    Fishers, Robert S.
    Medvedev, Andrei V.
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2014, 2 (02):
  • [46] High frequency oscillations as markers of epileptogenic tissue - End of the party?
    Fedele, Tommaso
    Ramantani, Georgia
    Sarnthein, Johannes
    CLINICAL NEUROPHYSIOLOGY, 2019, 130 (05) : 624 - 626
  • [47] Action potentials contribute to epileptic high-frequency oscillations recorded with electrodes remote from neurons
    Kobayashi, Katsuhiro
    Akiyama, Tomoyuki
    Ohmori, Iori
    Yoshinaga, Harumi
    Gotman, Jean
    CLINICAL NEUROPHYSIOLOGY, 2015, 126 (05) : 873 - 881
  • [48] Sample Entropy of High Frequency Oscillations for Epileptogenic Zone Localization
    Su, Yung-Chih
    Wu, Shun-Chi
    Chen, Chien
    Chou, Chen-Wei
    Hung, Sheng-Che
    Swindlehurst, A. Lee
    Kwan, Shang-Yeong
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 384 - 387
  • [49] Direct current shifts, high frequency oscillations and the epileptogenic zone
    Rampp, Stefan
    CLINICAL NEUROPHYSIOLOGY, 2015, 126 (01) : 2 - 4
  • [50] CLINICAL SIGNIFICANCE OF HIGH-FREQUENCY OSCILLATIONS RECORDED BY SCALP ELECTROENCEPHALOGRAM ON CHILDREN IDIOPATHIC PARTIAL EPILEPSY
    Cao, D.
    Chen, Y.
    Liao, J.
    Zhao, X.
    Hu, Y.
    Chen, L.
    Wen, F.
    Zhang, J.
    Hu, Z.
    Zhu, Y.
    Xu, Y.
    EPILEPSIA, 2013, 54 : 160 - 160