Accuracy of high-frequency oscillations recorded intraoperatively for classification of epileptogenic regions

被引:17
|
作者
Weiss, Shennan A. [1 ,2 ,3 ]
Staba, Richard J. [6 ]
Sharan, Ashwini [11 ]
Wu, Chengyuan [11 ]
Rubinstein, Daniel [10 ]
Das, Sandhitsu [12 ]
Waldman, Zachary [10 ]
Orosz, Iren [6 ]
Worrell, Gregory [4 ,5 ]
Engel, Jerome, Jr. [6 ,7 ,8 ,9 ]
Sperling, Michael R. [10 ]
机构
[1] State Univ New York Downstate, Dept Neurol, Brooklyn, NY 11203 USA
[2] State Univ New York Downstate, Dept Physiol & Pharmacol, Brooklyn, NY 11203 USA
[3] New York City Hlth Hosp, Dept Neurol, Brooklyn, NY USA
[4] Dept Neurol, Mayo Syst Elect Lab MSEL, Rochester, MI USA
[5] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[6] UCLA, David Geffen Sch Med, Dept Neurol, Los Angeles, CA 90095 USA
[7] UCLA, David Geffen Sch Med, Dept Neurobiol, Los Angeles, CA 90095 USA
[8] UCLA, David Geffen Sch Med, Dept Psychiat & Biobehavioral Sci, Los Angeles, CA 90095 USA
[9] UCLA, David Geffen Sch Med, Brain Res Inst, Los Angeles, CA 90095 USA
[10] Thomas Jefferson Univ, Dept Neurol & Neurosci, 901 Walnut St Suite 400, Philadelphia, PA 19107 USA
[11] Thomas Jefferson Univ, Dept Neurosurg, Philadelphia, PA 19107 USA
[12] Univ Penn, Penn Image Comp & Sci Lab, Philadelphia, PA 19143 USA
关键词
TEMPORAL-LOBE EPILEPSY; FAST RIPPLES; INTRACRANIAL EEG; SPIKE ACTIVITY; ELECTROCORTICOGRAPHY; SLEEP; SURGERY; REMIFENTANIL; SEVOFLURANE; DISCHARGES;
D O I
10.1038/s41598-021-00894-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To see whether acute intraoperative recordings using stereo EEG (SEEG) electrodes can replace prolonged interictal intracranial EEG (iEEG) recording, making the process more efficient and safer, 10 min of iEEG were recorded following electrode implantation in 16 anesthetized patients, and 1-2 days later during non-rapid eye movement (REM) sleep. Ripples on oscillations (RonO, 80-250 Hz), ripples on spikes (RonS), sharp-spikes, fast RonO (fRonO, 250-600 Hz), and fast RonS (fRonS) were semi-automatically detected. HFO power and frequency were compared between the conditions using a generalized linear mixed-effects model. HFO rates were compared using a two-way repeated measures ANOVA with anesthesia type and SOZ as factors. A receiver-operating characteristic (ROC) curve analysis quantified seizure onset zone (SOZ) classification accuracy, and the scalar product was used to assess spatial reliability. Resection of contacts with the highest rate of events was compared with outcome. During sleep, all HFOs, except fRonO, were larger in amplitude compared to intraoperatively (p < 0.01). HFO frequency was also affected (p < 0.01). Anesthesia selection affected HFO and sharp-spike rates. In both conditions combined, sharp-spikes and all HFO subtypes were increased in the SOZ (p < 0.01). However, the increases were larger during the sleep recordings (p < 0.05). The area under the ROC curves for SOZ classification were significantly smaller for intraoperative sharp-spikes, fRonO, and fRonS rates (p < 0.05). HFOs and spikes were only significantly spatially reliable for a subset of the patients (p < 0.05). A failure to resect fRonO areas in the sleep recordings trended the most sensitive and accurate for predicting failure. In summary, HFO morphology is altered by anesthesia. Intraoperative SEEG recordings exhibit increased rates of HFOs in the SOZ, but their spatial distribution can differ from sleep recordings. Recording these biomarkers during non-REM sleep offers a more accurate delineation of the SOZ and possibly the epileptogenic zone.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] High-frequency oscillations in the high-density scalp eeg: identification of the epileptogenic zone
    Ren, G.
    Yan, J.
    Sun, Y.
    Ren, J.
    Yang, C.
    Lv, R.
    Chen, C.
    Shi, W.
    Wang, S.
    Li, Z.
    Liu, M.
    Shao, X.
    Wang, Q.
    EPILEPSIA, 2023, 64 : 249 - 250
  • [22] Multiple band frequency analysis differentiates epileptogenic high-frequency oscillations from the high-frequency oscillations of extracranial ictal muscle activity on intracranial video EEG
    Otsubo, Hiroshi
    Ochi, A.
    Fujimoto, A.
    Imai, K.
    Go, C.
    Weiss, S.
    Donner, E.
    EPILEPSIA, 2007, 48 : 197 - 197
  • [23] CLASSIFICATION OF HIGH-FREQUENCY OSCILLATIONS IN SEARCH OF A PREICTAL STATE
    Malinowska, U.
    Bergey, G. K.
    Cervenka, M. C.
    Jouny, C. C.
    EPILEPSIA, 2013, 54 : 359 - 359
  • [24] Refining epileptogenic high-frequency oscillations using deep learning: a reverse engineering approach
    Zhang, Yipeng
    Lu, Qiujing
    Monsoor, Tonmoy
    Hussain, Shaun A.
    Qiao, Joe X.
    Salamon, Noriko
    Fallah, Aria
    Sim, Myung Shin
    Asano, Eishi
    Sankar, Raman
    Staba, Richard J.
    Engel, Jerome, Jr.
    Speier, William
    Roychowdhury, Vwani
    Nariai, Hiroki
    BRAIN COMMUNICATIONS, 2022, 4 (01)
  • [25] Interictal high-frequency oscillations, spikes, and connectivity profiles: A fingerprint of epileptogenic brain pathologies
    Sklenarova, Barbora
    Zatloukalova, Eva
    Cimbalnik, Jan
    Klimes, Petr
    Dolezalova, Irena
    Pail, Martin
    Kocvarova, Jitka
    Hendrych, Michal
    Hermanova, Marketa
    Gotman, Jean
    Dubeau, Francois
    Hall, Jeffery
    Pana, Raluca
    Frauscher, Birgit
    Brazdil, Milan
    EPILEPSIA, 2023, 64 (11) : 3049 - 3060
  • [26] Scalp-recorded high-frequency oscillations in atypical benign partial epilepsy
    Qian, Ping
    Li, Hui
    Xue, Jiao
    Yang, Zhixian
    CLINICAL NEUROPHYSIOLOGY, 2016, 127 (10) : 3306 - 3313
  • [27] High-frequency oscillations recorded in human medial temporal lobe during sleep
    Staba, RJ
    Wilson, CL
    Bragin, A
    Jhung, D
    Fried, I
    Engel, J
    ANNALS OF NEUROLOGY, 2004, 56 (01) : 108 - 115
  • [28] Diagnostic value of high-frequency oscillations for the epileptogenic zone: A systematic review and meta-analysis
    Wang, Yangshuo
    Xu, Jinshan
    Liu, Tinghong
    Chen, Feng
    Chen, Shuai
    Yuan, Liu
    Zhai, Feng
    Liang, Shuli
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2022, 99 : 82 - 90
  • [29] Influence of the location and type of epileptogenic lesion on scalp interictal epileptiform discharges and high-frequency oscillations
    Cuello-Oderiz, Carolina
    von Ellenrieder, Nicolas
    Dubeau, Francois
    Gotman, Jean
    EPILEPSIA, 2017, 58 (12) : 2153 - 2163
  • [30] Localization of epileptogenic foci by automatic detection of high-frequency oscillations based on waveform feature templates
    Wang, Xiaoying
    Xianghuan, Li
    Chen, Zhuang-Gui
    Ling, Yu
    Zhang, Pingping
    Lu, Zhenye
    Li, Yating
    Zhu, Jia
    Du, Yuxiao
    Yang, Qintai
    INTERNATIONAL JOURNAL OF INTELLIGENT SYSTEMS, 2022, 37 (12) : 11506 - 11521