Experimental investigation on thermal management for small container data center

被引:26
|
作者
Chu, Wen-Xiao [1 ]
Hsu, Chang-Sheng [1 ]
Tsui, Yeng-Yung [1 ]
Wang, Chi-Chuan [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Mech Engn, 1001 Univ Rd, Hsinchu 300, Taiwan
关键词
Container data center; Cooling performance; Recirculation; Rack cooling index; Supplied heat index; AISLE CONTAINMENT; AIR; PERFORMANCE;
D O I
10.1016/j.jobe.2018.10.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The energy consumptions of data centers are increasing dramatically and cooling systems using for controlling the operating temperature usually consume more than half of these energy. Thus, effective strategies on thermal management in data centers may have benefit on energy savings. In order to improve the power usage effectiveness (PUE) of data centers, the effects of air supply flowrate by computer room air handler (CRAH), intake flowrate of rack cooling fans, air supply grilles and heat load distribution on the cooling performance of a typical small container data center having overhead air supply system are investigated in this paper. The rack cooling index (RCI) and supply heat index (SHI) are incorporated to evaluate the local and average cooling performance of data racks. It is found that the intake flowrate of rack cooling fans plays dominant role, which is suggested to be greater than the air supply flowrate in normal operation. Meanwhile, the volumetric flowrate distribution of grilles is studied. The additional front grille before entering the cold aisle may improve the RCI and SHI of front rack (rack A), in which severe hot-air recirculation may occur in typical operation. Conversely, additional rear grille at the exit of cold aisle has negative effect on cooling performance of the last rack (rack E). Based on the measurement of local temperature distribution, the non-uniform heat load distribution in racks is proposed. Result shows that the RCI can be improved to 64% if more power is placed at lower half part, which is eligible for energy saving. However, the non-uniform heat load distribution shows limited improvement on the rear rack (rack E).
引用
收藏
页码:317 / 327
页数:11
相关论文
共 50 条
  • [41] NUMERICAL AND EXPERIMENTAL INVESTIGATION ON THERMAL MANAGEMENT OF AN OUTDOOR BATTERY CABINET
    Meng, X. Z.
    Lu, Z.
    Su, L. J.
    Luo, X. L.
    Wei, L. C.
    Jin, L. W.
    Chai, J.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 8A, 2015,
  • [42] Experimental investigation of an alternative battery pack thermal management system
    Tekin, Satilmis
    Turkakar, Goker
    JOURNAL OF ENERGY STORAGE, 2023, 59
  • [43] Experimental Study on the Effect of Uneven Heat Load on the Airflow Uniformity and Thermal Performance in a Small-Scale Data Center
    Chang, Ze-Wen
    Wang, Chi-Chuan
    PROCEEDINGS OF ASME 2023 HEAT TRANSFER SUMMER CONFERENCE, HT2023, 2023,
  • [44] THE SMALL DATA CENTER
    BROWN, B
    BYTE, 1989, 14 (06): : 286 - 287
  • [45] A Container Data Center Coupled With Radiative Sky Cooling
    Wen, Kai
    Zhang, Nianzu
    Li, Ruqun
    Wang, Xiaopo
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (12): : 3171 - 3176
  • [46] Experimental study of solving thermal heterogeneity problem of data center servers
    Nada, S. A.
    Attia, Ali M. A.
    Elfeky, K. E.
    APPLIED THERMAL ENGINEERING, 2016, 109 : 466 - 474
  • [47] Discussion on the technical path of data center information and communication thermal management
    Gao, Peng
    Liu, Hong
    Luo, Hailiang
    Jiang, Yuguang
    Liu, Haichao
    Wang, Zeqing
    Zhao, Jinming
    Wang, Yuanyuan
    Chen, Bohua
    Li, Ziyong
    ENERGY REPORTS, 2024, 11 : 2704 - 2714
  • [48] A critical review on the thermal management of data center for local hotspot elimination
    Zhao, Ruolan
    Du, Yahui
    Yang, Xiaochen
    Zhou, Zhihua
    Wang, Wufan
    Yang, Xueqing
    ENERGY AND BUILDINGS, 2023, 297
  • [49] The optimal thermal management study of a next-generation data center
    Lin, Ching-Chieh
    Shih, Yang-Cheng
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 26
  • [50] Interaction of EMC, acoustics and thermal management in the reliable operation of a data center
    Wu, CY
    Schmidt, RR
    Rawson, BP
    Wu, CY
    2002 3RD INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2002, : 565 - 573