Experimental investigation on thermal management for small container data center

被引:26
|
作者
Chu, Wen-Xiao [1 ]
Hsu, Chang-Sheng [1 ]
Tsui, Yeng-Yung [1 ]
Wang, Chi-Chuan [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Mech Engn, 1001 Univ Rd, Hsinchu 300, Taiwan
关键词
Container data center; Cooling performance; Recirculation; Rack cooling index; Supplied heat index; AISLE CONTAINMENT; AIR; PERFORMANCE;
D O I
10.1016/j.jobe.2018.10.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The energy consumptions of data centers are increasing dramatically and cooling systems using for controlling the operating temperature usually consume more than half of these energy. Thus, effective strategies on thermal management in data centers may have benefit on energy savings. In order to improve the power usage effectiveness (PUE) of data centers, the effects of air supply flowrate by computer room air handler (CRAH), intake flowrate of rack cooling fans, air supply grilles and heat load distribution on the cooling performance of a typical small container data center having overhead air supply system are investigated in this paper. The rack cooling index (RCI) and supply heat index (SHI) are incorporated to evaluate the local and average cooling performance of data racks. It is found that the intake flowrate of rack cooling fans plays dominant role, which is suggested to be greater than the air supply flowrate in normal operation. Meanwhile, the volumetric flowrate distribution of grilles is studied. The additional front grille before entering the cold aisle may improve the RCI and SHI of front rack (rack A), in which severe hot-air recirculation may occur in typical operation. Conversely, additional rear grille at the exit of cold aisle has negative effect on cooling performance of the last rack (rack E). Based on the measurement of local temperature distribution, the non-uniform heat load distribution in racks is proposed. Result shows that the RCI can be improved to 64% if more power is placed at lower half part, which is eligible for energy saving. However, the non-uniform heat load distribution shows limited improvement on the rear rack (rack E).
引用
收藏
页码:317 / 327
页数:11
相关论文
共 50 条
  • [21] Airflow Management on the Efficiency Index of a Container Data Center Having Overhead Air Supply
    Wang, Cheng-Hao
    Tsui, Yeng-Yung
    Wang, Chi-Chuan
    JOURNAL OF ELECTRONIC PACKAGING, 2017, 139 (04)
  • [22] Improvements of Airflow Distribution in a Container Data Center
    Wang, I-Nuo
    Tsui, Yeng-Yung
    Wang, Chi-Chuan
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 1819 - 1824
  • [23] Experimental and numerical investigation on thermal performance of data center via fan-wall free cooling technology
    Lan, Jiang
    Zhang, Zujing
    Liang, Xing
    Wu, Hongwei
    Wang, Gang
    Mao, Ruiyong
    APPLIED THERMAL ENGINEERING, 2023, 228
  • [24] COMPARISON OF NUMERICAL MODELING TO EXPERIMENTAL DATA IN A SMALL DATA CENTER TEST CELL
    Cruz, Ethan
    Joshi, Yogendra
    Iyengar, Madhusudan
    Schmidt, Roger
    IPACK 2009: PROCEEDINGS OF THE ASME INTERPACK CONFERENCE 2009, VOL 2, 2010, : 953 - 961
  • [25] An investigation of thermal stratification in refrigerated container yards
    Budiyanto, Muhammad Arif
    Shinoda, Takeshi
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 21
  • [26] THERMAL ZONES FOR MORE EFFICIENT DATA CENTER ENERGY MANAGEMENT
    Hamann, Hendrik F.
    Lopez, Vanessa
    Stepanchuk, Andrew
    2010 12TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 2010,
  • [27] Effect of CRAC units layout on thermal management of data center
    Nada, S. A.
    Said, M. A.
    APPLIED THERMAL ENGINEERING, 2017, 118 : 339 - 344
  • [28] Improving Data Center Energy Efficiency With Advanced Thermal Management
    Chainer, Timothy J.
    Schultz, Mark D.
    Parida, Pritish R.
    Gaynes, Michael A.
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2017, 7 (08): : 1228 - 1239
  • [29] Dynamic thermal environment management technologies for data center: A review
    Du, Yahui
    Zhou, Zhihua
    Yang, Xiaochen
    Yang, Xueqing
    Wang, Cheng
    Liu, Junwei
    Yuan, Jianjuan
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2023, 187
  • [30] A review of thermal management and innovative cooling strategies for data center
    Nadjahi, Chayan
    Louahlia, Hasna
    Lemasson, Stephane
    SUSTAINABLE COMPUTING-INFORMATICS & SYSTEMS, 2018, 19 : 14 - 28