Membrane based on decyl-18-crown-6 for a potassium selective sensor

被引:0
|
作者
Hopârtean, E
Pica, EM
Ana, C
Cosma, V
Hopârtean, I
机构
[1] Tech Univ Cluj Napoca, R-3400 Cluj Napoca, Romania
[2] Inst Chem, R-3400 Cluj Napoca, Romania
来源
CHEMIA ANALITYCZNA | 2001年 / 46卷 / 01期
关键词
crown ethers; potassium PVC membrane sensors; potassium potentiometric determination; ion-selective electrode; ionophores;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four kinds of 18-crown-6 derivatives were studied as ionophores in plasticized poly(vinyl chloride) (PVC) in order to obtain potassium selective membrane. The properties of the sensor were studied in detail. For the optimization of the selectivity toward K+ over Na+ the influence of the following factors was studied: nature and concentration of the ionophore; nature and concentration of the plasticizer and lipophilic salt addition. The potassium ion-selective membrane electrode was designed. The electrode has a fast and Nernstian response in the 1 x 10(-1)-2 x 10(-5) mol l(-1) K+, after six months of continuous measurements. The change of pH in the range 2-10.5 does not affect the response of the electrode. The internal resistance of the electrode was measured. The electrode shows a good stability and can be used in the potentiometric determination.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 50 条
  • [21] A novel iron(III) selective membrane electrode based on benzo-18-crown-6 crown ether and its applications
    Ekmekci, Guler
    Uzun, Demet
    Somer, Guler
    Kalayci, Sukru
    JOURNAL OF MEMBRANE SCIENCE, 2007, 288 (1-2) : 36 - 40
  • [22] Polyindole modified potassium ion-sensor using dibenzo-18-crown-6 mediated PVC matrix membrane
    Pandey, P.C.
    Prakash, R.
    Sensors and Actuators, B: Chemical, 1998, B46 (01): : 61 - 65
  • [23] Selective and efficient liquid membrane transport of thallium (III) ion by potassium-dicyclohexyl-18-crown-6 as specific carrier
    Zolgharnein, Javad
    Shams, Hassan
    Azimi, Gholamhassan
    SEPARATION SCIENCE AND TECHNOLOGY, 2007, 42 (10) : 2303 - 2314
  • [24] POTASSIUM-SELECTIVE PVC MEMBRANE ELECTRODES BASED ON BIS(CROWN ETHER) AND POLY(CROWN ETHER)
    KIMURA, K
    MAEDA, T
    TAMURA, H
    SHONO, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 95 (01): : 91 - 101
  • [25] Tetrakis(isothiocyanato) manganese(II) bis[aqua(18-crown-6) potassium] (18-crown-6)(thiocyanato)potassium
    Chekhlov, A. N.
    RUSSIAN JOURNAL OF COORDINATION CHEMISTRY, 2008, 34 (04) : 264 - 269
  • [26] A highly selective fluorescent sensor for Al3+ based on an aza-18-crown-6 derivative
    Song Jingjing
    Hu Yang
    Zhao Fang
    Hu Shengli
    JOURNAL OF CHEMICAL RESEARCH, 2015, (10) : 603 - 605
  • [27] Tetrakis(isothiocyanato)manganese(II) bis[aqua(18-crown-6)potassium] (18-crown-6)(thiocyanato)potassium
    A. N. Chekhlov
    Russian Journal of Coordination Chemistry, 2008, 34 : 264 - 269
  • [28] Preconcentration and separation of trace amounts of strontium ions from alkali and alkaline earth metal ions using octadecyl silica membrane disks modified with decyl-18-crown-6 and its determination by flame atomic absorption spectrometry
    Shamsipur, M
    Raoufi, F
    MIKROCHIMICA ACTA, 2001, 137 (3-4) : 163 - 167
  • [29] Aqueous Zinc Ion Battery with Potassium Selective Hyper Cross-Linked Dibenzo-18-Crown-6-Ether Membrane
    Bavdane, Priyanka P.
    Bhatt, Bhavana
    Nikumbe, Devendra Y.
    Dave, Vidhiben
    Sreenath, Sooraj
    Babujohn, Nisar Ahamed
    Nagarale, Rajaram K.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (10)
  • [30] Preconcentration and Separation of Trace Amounts of Strontium Ions from Alkali and Alkaline Earth Metal Ions Using Octadecyl Silica Membrane Disks Modified with Decyl-18-Crown-6 and Its Determination by Flame Atomic Absorption Spectrometry
    Mojtaba Shamsipur
    Farhad Raoufi
    Microchimica Acta, 2001, 137 : 163 - 167